• Title/Summary/Keyword: Energy efficient building

Search Result 378, Processing Time 0.029 seconds

Investigation of Problem and System by Energy Application in City Level (도시차원에서의 에너지 적용에 따른 문제점 및 체계 검토)

  • Park, Yool;Kim, Sam-Uel;Park, Jin-Young;Lee, Sang-Jin;Yee, Jurng-Jae
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.3
    • /
    • pp.51-58
    • /
    • 2009
  • Recently, many social, economical and political problems have occurred in the field of urban energy supply because of the depletion of fossil fuels and the international climate change agreements and the current energy-related laws focus on individual buildings which makes them difficult to implement. Also, the policies for energy savings have increased day by day, but it is difficult to establish efficient urban plan because of lack of integrated policies and institutions. Current legal systems for urban plan does not cover domestic and international climate change agreements, energy related industry's structural changes and other environmental problems such as embodied energy and global warming. This paper tries to investigate current conditions of legal system to provide fundamental materials for improving energy conservation in urban plan.

Design of Ground-Coupled Heat Pump (GCHP) System and Analysis of Ground Source Temperature Variation for School Building (학교 건물용 지열 히트펌프 시스템 설계와 지중 순환수 온도 변화 분석)

  • Sohn, Byonghu
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.16 no.1
    • /
    • pp.17-25
    • /
    • 2020
  • Ground-coupled heat pump (GCHP) systems have become an efficient alternative to conventional cooling and heating methods due to their higher energy using efficiency. Although some experimental and simulation works related to performance analysis of GCHP systems for commercial buildings have been done, relatively little has been reported on the performance evaluation of GCHP systems for school buildings. The purpose of this simulation study is to evaluate the performance of a hypothetical GCHP system for a school building in Seoul. We collected various data of building specifications and construction materials for the building and then modeled to calculate hourly building loads with SketchuUp and TRNSYS V17. In addition, we used GLD (Ground Loop Design) V2016, a GCHP system design and simulation software, to design the GCHP system for the building and to simulate temperature of circulating water in ground heat exchanger. The variation of entering source temperature (EST) into the system was calculated with different prediction time and then each result was compared. For 20 years of prediction time, EST for baseline design (Case A) based on the hourly simulation results were outranged from the design criteria.

Analysis of City Level Energy Usage in Busan (부산시 도시차원에서의 에너지 사용 현황 분석)

  • Kim, Nam-Wook;Hong, Jin-Young;Park, Yool
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1185-1190
    • /
    • 2009
  • Korea is an industrial country that overspends energy and has a policy that is more focused on a supply side. When an urban developmental program is to set up, surveys are carried out only with the respect to electricity, telecommunication, gas, and heating sources. Based on the existing survey results, the problems related to the supply side are being dealt with more importantly and the quantities of those supplies are estimated only by each energy source. The aim of this study is to provide basic information on energy consumption patterns of a diverse comsumer groups including industry, transportation, commerce, public and household to plan diverse energy policies. Through this basic information, it may be possible to analyze the energy consumption pattern by each consumer group and provide data for setting up efficient energy policies by the government. The energy consumption map that are analyzed and developed by the data obtained from Busan municipal area will be deposited and used as a part of the national energy statistics.

  • PDF

Energy Efficient LED Lighting Design to utilize the Sun Light (태양광 활용을 위한 효율적 LED 조명기구 설계 방안)

  • Jeong, Hak-Geun;Han, Soo-Bin;Jang, Cheol-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.2
    • /
    • pp.31-36
    • /
    • 2011
  • LED is expected as an environmentally friendly next generation light source with its good reliability and long lifetime. The light sources for illumination have a variety of applications in the indoor and outdoor, and the variation of optical power and color rendering of the light source limits their applications. Therefore, it is necessary to research the LED lamp and its luminaire to minimize the variation of dynamic characteristics and to improve the color rendering due to that illuminating environment. Daylight is very good light source to human and can be used as primary or a secondary light source with benefits of energy, productivity and health.This paper presents the design method of LED lighting system to improve poor property in terms of CR(color redering) characteristic to use daylight effectively.

A Study on the Analysis of Energy Performance of High-rise Residential Buildings (초고층 주거건물의 에너지 성능 분석에 관한 연구)

  • Seok Ho-Tae;Kim Jang-Han;Chung Man-Seok
    • Journal of the Korean housing association
    • /
    • v.15 no.4
    • /
    • pp.35-43
    • /
    • 2004
  • The environment pollution is very important problem. Even at the field of architecture, a study about method of saving energy and constructing environment friendly building will have performed with activity. But trends of Korea housing market are changed that the height of building become more higher and the level of comfort going up. Therefore, these requirements force to increase the energy usage for indoor environmental controls. Thus, the purpose of this study is to reduce the heating and cooling energy requirements of High-rise Residential Buildings by the analysis of Energy Performance. From now on, we search improvement plan for the most efficient Energy Saving at present High-rise Residential Buildings.

Case Studies of HVAC System through Energy audit (공조시스템의 에너지진단 사례)

  • Kim, Doo-Sung;Kim, Chun-Yong;Um, Chul-Jun;Song, Euy
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.66-71
    • /
    • 2008
  • Energy audit was started in 2006 that Korea Government Policy for Energy saving. Who used over 2,000toe/yr(tons of oil equivalent) energy consumption has to perform Energy audit program of obligation every five years with auditing company. HANMI C&E as a company authorized by Government has diagnosed various type building. It shows four case studies of HVAC system in office building through Energy audit. This studies present efficient recommendation method for improving system performance.

  • PDF

Case Studies on Space Zoning and Passive Façade Strategies for Green Laboratories

  • Kim, Jinho
    • Architectural research
    • /
    • v.22 no.2
    • /
    • pp.41-52
    • /
    • 2020
  • Laboratory buildings with specialized equipment and ventilation systems pose challenges in terms of efficient energy use and initial construction costs. Additionally, lab spaces should have flexible and efficient layouts and provide a comfortable indoor research environment. Therefore, this study aims to identify the correlation between the facade of a building and its interior layout from case studies of energy-efficient research labs and to propose passive energy design strategies for the establishment of an optimal research environment. The case studies in this paper were selected from the American Institute of Architects Committee on the Environment Top Ten Projects and Leadership in Energy and Environmental Design (LEED) certified research lab projects. In this paper, the passive design strategies of space zoning, façade design devices to control heating and cooling loads were analyzed. Additionally, the relationships between these strategies and the interior lab layouts, lab support spaces, offices, and circulation areas were examined. The following four conclusions were drawn from the analysis of various cases: 1) space zoning for grouping areas with similar energy requirements is performed to concentrate similar heating and cooling demands to simplify the HVAC loads. 2) Public areas such as corridor, atrium, or courtyard can serve as buffer zones that employ passive solar design to minimize the mechanical energy load. 3) A balanced window-to-wall ratio (WWR), exterior shading devices, and natural ventilation systems are applied according to the space programming energy requirements to minimize the dependence on mechanical service. 4) Lastly, typical laboratory space zoning categories can be revised, reversed, and even reconfigured to minimize the energy load and adjust to the site context. This study can provide deep insights into various design strategies employed for construction of green laboratories along with intuitive arrangement of various building components such as laboratory spaces, lab support spaces, office spaces, and common public areas. The key findings of this study can contribute towards creating improved designs of laboratory facilities with reduced carbon footprint and greenhouse emissions.

Case Studies of best practices through Energy audit (에너지진단 우수 사례소개)

  • Um, Chul-Jun;Song, Euy;Kim, Chun-Yong;Kim, Doo-Sung
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.505-510
    • /
    • 2008
  • Improving energy efficiency is the important thing of energy saving strategies that was shown up result of IEA meeting and the G8 Summit. Energy audit was started in 2006 that Korea government policy for improving energy efficiency. Who used over 2,000toe/yr(tons of oil equivalent per year) energy consumption has to perform energy audit program of obligation every five years with auditing company. HANMI C&E as a company authorized by Government has diagnosed various type building. This case studies are chosen to best practices by KEMCO. This studies present efficient recommendation methods for improving system performance.

  • PDF

Comparative Studies on Lighting Environment and Energy Performance depending on the Transmittance of Window and Slat Angle of Blind (창호의 투과율과 블라인드 슬랫각도에 따른 빛환경 및 에너지성능 비교 연구)

  • Sim, Se-Ra;Yoon, Jong-Ho;Shin, U-Cheul
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.256-263
    • /
    • 2011
  • Recently, curtain wall structure is constructed according to increasing high rise building. Glass is usually used in opening of curtain wall structure and window area ratio is finally increased. Excessive Daylighting and solar radiation by large window area ratio cause discomfort glare and add to cooling load in the case of office that is heavy on lighting and cooling. Therefore, this study suggests to use low transmittance window for solve those problems. Indoor lighting environment and building energy performance were analyzed by increasing transmittance from 10% to 90% and comparing fixed venetian blind. Consequently, the range of transmittance that is possible to daylighting and prevent discomfort glare. Secondary energy consumption is efficient in the case that transmittance is the range of from 20% to 50%, primary energy consumption is nice on from 20% to 40%. If those result put together, the range of window transmittance from 30% to 50% is proper in the office in lighting environment and energy consumption aspects.

  • PDF

Design of Thermally Coupled Distillation Process Utilizing Existing Columns (기존 증류탑을 이용한 열복합 증류공정의 설계)

  • Lee, Moon Yong;Kim, Young Han
    • Korean Chemical Engineering Research
    • /
    • v.46 no.5
    • /
    • pp.1017-1022
    • /
    • 2008
  • Though many divided wall columns are implemented in field as energy-efficient distillation columns, its application is limited due to the difficulty of building a new column. A novel energy-efficient distillation system utilizing the existing columns is proposed here. The proposed can reduce the energy consumption by about 39% comparing with the existing system. And it is shown that the proposed improves the column operability over the existing. The tray numbers of the added columns have no significant influence on the composition of a side draw.