• 제목/요약/키워드: Energy compensator

검색결과 125건 처리시간 0.025초

순간전압강하 보상기의 설계와 해석 (Design and Analysis of Instantaneous Voltage Drop Compensator)

  • 이택기;현동석;황용하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.478-481
    • /
    • 1991
  • This paper discusses the principle and structure of instantaneous voltage drop compensator, which protects damage from instantaneous voltage drop in systems such as computer, variable speed drive, high voltage discharge-lamp, magnet switch. When instantaneous voltage drop occurs, control circuits detect it, then produce output voltage the same as normal condition voltage. Instantaneous voltage drop compensator has condenser bank as energy storage component, so system can be made small, light weight compared with UPS. In normal state, utility source transfers power, and in instantaneous voltage drop state, the energy of condenser bank transfers power through inverter, so high efficiency, compact, and especially low cost system can be manufactured.

  • PDF

A Study on Stability Improvement of High Energy Laser Beam Wavefront Correction System

  • Jung, Jongkyu;Lee, Sooman
    • 한국컴퓨터정보학회논문지
    • /
    • 제23권2호
    • /
    • pp.1-7
    • /
    • 2018
  • The adaptive optics for compensating for optical wavefront distortion due to atmospheric turbulence has recently been used in systems that improve beam quality by eliminating the aberrations of high power laser beam wavefront. However, unseen-mode, which can not be measured in the wavefront sensor, increases the instability of the laser beam wavefront compensator on the adaptive optics system. As a method for improving such instability, a mathematical method for limiting the number of singular values is used when generating the command matrix involved in generation of the drive command of the wavefront compensator. In the past, however, we have relied solely on experimental methods to determine the limiting range of the singular values. In this paper, we propose a criterion for determining the limiting range of the singular values using the driving characteristics and the correlation technique of the wavefront compensator's actuators and have proved its performance experimentally.

토션바 중력보상기를 적용한 하지용 외골격 장치 실험연구 (Experimental Study of a lower body exoskeleton applying a torsion bar gravity compensator)

  • 최형식;이동준;윤종수
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2011년도 후기공동학술대회 논문집
    • /
    • pp.97-98
    • /
    • 2011
  • This paper is about the study of a new exo-skeleton device applying a gravity compensator. The exo-skeleton devices is to reduce the external torque applied to the human body joint for the purpose of helping the disabled, reducing heavy payload for industry workers or military soldiers. Most of the exoskeleton devices are actuated by the motors, but motors are limited in energy such that a short durability is always a big problem. In this paper, an exoskeleton device using a new gravity compensator based on a torsion bar is proposed to reduce the torque load applied to human body joints. The exoskeleton device is designed for the lower body of human. Analyses on the torsion bar spring and link of the exoskeleton device using FEM method were performed. To reduce the applied torque to the human joint, a torsion bar gravity compensator is applied to the exoskeleton. The effect of the torsion bar compensator for the exoskeleton device was verified through load test using developed test equipment.

  • PDF

Design of an Asymmetrical Three-phase Inverter for Load Balancing and Power Factor Correction Based on Power Analysis

  • Mokhtari, M.;Golshannavaz, S.;Nazarpour, D.;Aminifar, F.
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권3호
    • /
    • pp.293-301
    • /
    • 2011
  • This paper presents a novel theoretical method based on power analysis to obtain voltage reference values for an inverter-based compensator. This type of compensator, which is installed in parallel with the load, is usually referred to as the active filter. The proposed method is tailored to design the compensator in such a way that it can simultaneously balance the asymmetric load, as well as correct the power factor of the supply side. For clarity, a static compensator is first considered and a recursive algorithm is utilized to calculate the reactance values. The algorithm is then extended to calculate voltage reference values when the compensator is inverter based. It is evident that the compensator would be asymmetric since the load is unbalanced. The salient feature associated with the proposed method is that the circuit representation of system load is not required and that the load is recognized just by its active and reactive consumptions. Hence, the type and connection of load do not matter. The validity and performance of the new approach are analyzed via a numerical example, and the obtained results are thoroughly discussed.

4MV X-선을 이용한 조직보상체 두께비 연구 및 응용 (A study on tissue compensator thickness ratio and an application for 4MV X-rays)

  • 김영범;정희영;권영호;김유현
    • 대한방사선치료학회지
    • /
    • 제8권1호
    • /
    • pp.55-61
    • /
    • 1996
  • A radiation beam incident on irregular or sloping surface produces an inhomogeneity of absorbed dose. The use of a tissue compensator can partially correct this dose inhomogeneity. The tissue compensator should be made based on experimentally measured thickness ratio. The thickness ratio depends on beam energy, distance from the tissue compensator to the surface of patient, field size, treatment depth, tissue deficit and other factors. In this study, the thickness ratio was measured for various field size of $5cm{\times}5cm,\;10cm{\times}10cm,\;15cm{\times}15cm,\;20cm{\times}20cm$ for 4MV X-ray beams. The distance to the compensator from the X-ray target was fixed, 49cm, and measurement depth was 3, 5, 7, 9 cm. For each measurement depth, the tissue deficit was changed from 0 to(measurement depth-1)cm by 1cm increment. As a result, thickness ratio was decreased according to field size and tissue deficit was increased. Use of a representative thickness ratio for tissue compensator, there was $10\%$ difference of absorbed dose but use of a experimentally measured thickness ratio for tissue compensator, there was $2\%$ difference of absorbed dose. Therefore, it can be concluded that the tissue compensator made by experimentally measured thickness ratio can produce good distribution with acceptable inhomogeneity and such tissue compensator can be effectively applied to clinical radiotherapy.

  • PDF

Proposal and Development of A Cylinder Type Liquid Variable Compensator for Radiation Therapy

  • Ochiai, Makoto;Takahashi, Seiji;Takada, Yuusuke;Hayakawa, Yoshinori
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.222-224
    • /
    • 2002
  • In proton and heavy ion radiotherapy, compensators are required to modify the energy of heavy ion, to compensate the local difference of tumor depth. Conventional compensators have to be created, exchanged, and stored for each patient and for each irradiation directions. A Cylinder Type Liquid Variable Compensator is and is under development. Hexagonal cylinders will be arranged in honeycomb structure. In which air and fluid are divided by hexagonal pistons. The position of each piston will be changed in each cylinder for adjusting the thickness of fluid for variable compensator. The location of each hexagonal piston is determined by each controlling cylinder connected to the hexagonal cylinder by inlet pipes of fluid. Each controlling cylinder includes controlling a piston, which is moved mechanically. Each controlling cylinder is to be moved by a motor driven by a computer.

  • PDF

Design and Analysis of Fuzzy Control in a Variable Speed Refrigeration System

  • Hua, Li;Jeong, Seok-Kwon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권2호
    • /
    • pp.61-69
    • /
    • 2007
  • This paper deals with fuzzy control with a feedforward compensator to progress both energy saving and coefficient of performance (COP) in a variable speed refrigeration system. Both the capacity and superheat are controlled simultaneously and independently in the system. By adopting the fuzzy theory, the controller design for the capacity and superheat is possible without depending on a dynamic model of the system. Moreover, the feedforward compensator of the superheat can reduce influence of the interfering loop between the capacity and superheat. Some experiments are conducted to design appropriate fuzzy controller by an iteration manner. The results show that the proposed fuzzy controller with the compensator can establish good control performances for the complicated refrigeration system in spite of its inherent strong non-linearity. Also, the fuzzy control performances were investigated by comparing to the model based PI control experimental results to evaluate transient behavior under the control.

Comparative study of control strategies for the induction generators in wind energy conversion system

  • Giribabu, D.;Das, Maloy;Kumar, Amit
    • Wind and Structures
    • /
    • 제22권6호
    • /
    • pp.635-662
    • /
    • 2016
  • This paper deals with the comparison of different control strategies for the Induction generators in wind energy conversion system. Mainly, two types of induction machines, Self excited induction generator (SEIG) and doubly Fed Induction generators (DFIG) are studied. The different control strategies for SEIG and DFIG are compared. For SEIG, Electronic load Controller mechanism, Static Compensator based voltage regulator are studied. For DFIG the main control strategy namely vector control, direct torque control and direct power control are implemented. Apart from these control strategies for both SEIG and DFIG to improve the performance, the ANFIS based controller is introduced in both STATCOM and DTC methods. These control methods are simulated using MATLAB/SIMULINK and performances are analyzed and compared.

Design of Nonlinear Lead and/or Lag Compensators

  • Nassirharand, Amir;Firdeh, Seyed Reza Mousavi
    • International Journal of Control, Automation, and Systems
    • /
    • 제6권3호
    • /
    • pp.394-400
    • /
    • 2008
  • A known nonlinear compensator design approach is adapted to allow design of nonlinear lead and/or lag compensators, and a number of MATLAB functions are developed that automate the compensator design procedure. With this design tool, control engineers would be able to rapidly design nonlinear lead and/or lag compensators. An example of a tutorial nature is presented.

유.무효 전력 제어를 통한 풍력발전단지의 효율적인 운전 (A Study on Active and Reactive Power Control for Efficient Operations of Wind Farm)

  • 장성일;김지원;김광호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1351-1354
    • /
    • 2002
  • Wind farm which are composed with wind turbine generators can be a good alternatives to solve environmental problem and solutions to cope with energy crisis for using wind energy. Until now, these wind turbine generators have been being studied on the viewpoint of only active power control for reducing the burden of main grid. In this control scheme, we might demand a reactive power compensator in order to make reparation for the reactive power produced from wind turbine generator itself. Therefore, if the reactive power as well as active power of wind turbine generator were controlled according to the demand of reactive power, the installation of a additional reactive power compensator could be reduced. This paper presents the control method of a active and reactive power for wind turbine generators by means of SVPWM(Space Vector Pulse Width Modulation) inverting method and describes a operational coordination of wind turbine generators. The proposed power control algorithm can simply produce the output power of wind turbine generator needed in wind farm, which can reduce the power of main grid more and exclude a supplementary reactive power compensator. We assumed that wind farm are composed with two kinds of wind turbine generators, AC/DC/AC and induction generator types.

  • PDF