• Title/Summary/Keyword: Energy Value

Search Result 6,223, Processing Time 0.034 seconds

A Study on the Energy Consumption Cost in the Winter and Calorific Value by Insulated Gang-form (단열갱폼 적용에 따른 동절기 보양비 사용량 및 발열량 검토에 관한 실험적 연구)

  • Nam, Kyung-Yong;Choi, Suk;Ahn, Sung-Jin;Lim, Myung-Kwan
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.1
    • /
    • pp.53-60
    • /
    • 2020
  • This paper aims to examine the insulation performance of insulated gang form by changing the energy (power) consumption and concrete calorific value to assist in concrete protection in cold weather. According to the test results, the general gang form will generate three times the energy (power) consumption for 12 hours after the concrete is poured. In contrast, insulated gang foam consumed no energy (power) for 21 hours after pouring. The final power consumption was 3.7 times higher than that of the general gang form, confirming the improved performance of insulated gang form with regard to energy (power) consumption. The calorific value examination shows that the calorific value changes significantly according to the change of outside temperature after concrete placement in the case of the general gang form. However, in the case of the insulated gang form, only a slight heat loss occurred in the part of the frame, and it showed a constant heating pattern from the concrete casting to the demolding of the mold.

Characteristics of Low Calorific Value of Sewage Sludge by Drying Method (수직원통식 박막 건조방식에 의한 하수슬러지의 저위발열량 특성)

  • Mo, Jounggun;Lee, Kwangsung;Chung, Hanshik
    • Journal of Power System Engineering
    • /
    • v.21 no.5
    • /
    • pp.55-62
    • /
    • 2017
  • In this study, the water content and the low calorific value of the dried sludge are analyzed by using a vertical cylinder type indirect heating type dryer for evaluatation of energy source value. The vertical cylindrical thin film dryer was an Okadora Pilot Plant, and the dryer was indirect heating vertical thin film type. The internal standard consisted of 500 mm in diameter and 700 mm in height. In the drying experiment, 10 kg of dehydrated sewage sludge was added to the dryer and the total amount of the sludge was adjusted to 27 times by variable of the time, the number of revolutions and the steam temperature. The results of analysis of the 27th experiment component of the dried product showed that the average low calorific value of about 11.2 MJ/kg and the water content of 6%. This is satisfy the fuel use standard of the thermal power plant of the sludge.

A Study on the Voxel Coloring using Multi-variable Thresholding (다중 가변 문턱값을 이용한 복셀 칼라링 기법에 관한 연구)

  • Kim Hyo-Sung;Lee Sang-Wook;Nam Ki-Gon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.5
    • /
    • pp.1102-1110
    • /
    • 2005
  • In this paper, we proposed a advanced approach to resolve the trade-off problem for the threshold value determining the photo-consistency in the previous algorithms. The threshold value for the surface voxel is substituted the photo-consistency value of the inside voxel. As iterating the voxel coloring process, the threshold is approached to the optimal value for the individual surface voxel. we present an energy minimization formulation of the binary labeling problem that surface voxels classify into opacity or transparency. The energy formula consists of the data term and the smoothness term. As considering neighboring voxels in the labeling problem, the unevenness of reconstructed surface is reduced. The labeling whose energy is the global minimum can be computed using a graph cut.

THE FEEDING AND ECONOMIC VALUE OF MAIZE COB MEAL FOR BROILER CHICKENS

  • Ochetim, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.6 no.3
    • /
    • pp.367-371
    • /
    • 1993
  • The feeding value of maize cob meal was investigated in a trial involving one hundred and forty Arbor Acre day-old chicks raised to eight weeks of age. The maize cob meal which contained 32.5% fibre, 2.5% protein and had a gross energy value of 2,550 kcal/kg, was incorporated into the experimental diets at either 0, 2.9, 5.8, 11.6 or 23.2% level. All diets were formulated to contain 3,200 kcal/kg of metabolizable energy and approximately 22% protein by varying the proportions of maize and whole cooked soyabean meal in the diets. The inclusion of maize cob meal up to 11.6% in the diet did not significantly (p>0.05) affect body weight gains, feed consumption and utilization, as well as carcass yield and dressing percentage. However, at the 23.2% level of maize cob meal inclusion, body weight gains, feed utilization and carcass yields were significantly (p<0.05) reduced. The use of maize cob meal reduced feed cost for raising birds and either maintained or improved gross profit returns with up to 11.6% level of inclusion in the diet. It was concluded that maize cob meal can be included up to 11.6% in the diet of broiler chickens provided dietary energy concentration is maintained at 3,200 kcal of metabolisable energy per kilogramme of feed by using high energy density feed ingredient such as boiled whole seed soyabean meal.

Application of Back-propagation Algorithm for the forecasting of Temperature and Humidity (온도 및 습도의 단기 예측에 있어서 역전파 알고리즘의 적용)

  • Jeong, Hyo-Joon;Hwang, Won-Tae;Suh, Kyung-Suk;Kim, Eun-Han;Han, Moon-Hee
    • Journal of Environmental Impact Assessment
    • /
    • v.12 no.4
    • /
    • pp.271-279
    • /
    • 2003
  • Temperature and humidity forecasting have been performed using artificial neural networks model(ANN). We composed ANN with multi-layer perceptron which is 2 input layers, 2 hidden layers and 1 output layer. Back propagation algorithm was used to train the ANN. 6 nodes and 12 nodes in the middle layers were appropriate to the temperature model for training. And 9 nodes and 6 nodes were also appropriate to the humidity model respectively. 90% of the all data was used learning set, and the extra 10% was used to model verification. In the case of temperature, average temperature before 15 minute and humidity at present constituted input layer, and temperature at present constituted out-layer and humidity model was vice versa. The sensitivity analysis revealed that previous value data contributed to forecasting target value than the other variable. Temperature was pseudo-linearly related to the previous 15 minute average value. We confirmed that ANN with multi-layer perceptron could support pollutant dispersion model by computing meterological data at real time.

A Study on the Application State of the Fenestration Energy Consumption Efficiency Rating System in Construction Field (소규모 민간건축 시공현장에 있어서 창호에너지 소비효율등급제의 적용 현황에 관한 연구)

  • Kang, Suk-Pyo;Jin, Eun-Mi;Yun, Yeo-Myun;Park, Sang-Eun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.24-25
    • /
    • 2014
  • Up to now, most the fenestration industry is consisted of glazing and window frame in Korea. According to the Fenestration Energy Consumption Efficiency Rating System and Energy Saving Design Standards of Buildings, u-value of fenestration is defined as the value of calculation with glazing and frame. For this reason, when applying for a building permit, in most cases, the official approval test report of the set of windows and doors is used. Nevertheless, in windows construction progresses, most construction manager take delivery of the glazing and frame separately. For those reason, windows and doors are constructed regardless of the report of the Fenestration Energy Consumption Efficiency Rating System in most construction fields. From now on, the research of the connection method between reality of policy and reality of construction fields should be carried out.

  • PDF

DR Responses to X-Ray: in Terms of Absorbed Energy

  • Kim, Do-Il;Lee, Hyoung-Koo;Kim, Sung-Hyeon;Ho, Dong-Su;Suh, Tae-Suk;Choe, Bo-Young
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.389-392
    • /
    • 2002
  • Digital radiography (DR) is being developed for numerous applications in medical imaging. For understanding DR image, it is necessary to comprehend DR responses to X-ray in terms of absorbed energy. This study reports on the relationship of absorbed energy in the scintillator vs. pixel value of detector. Pixel value and exposure were measured from 50 kVp to 120 kVp until the detector was saturated. For representing radiation produced at the X-ray tube, we used program Srs-78 and compared experimental exposure with calculated exposure. Absorbed energy was acquired using spectrum and we got the relation between the two values.

  • PDF

A Study on the Photon Energy Characteristics of ZnO Thin Film According to Coating Thickness (ZnO 박막의 증착 두께에 따른 Photon Energy 특성에 관한 연구)

  • Lee, Jung-Il;Seo, Jang-Soo;Jung, Sung-Gyo;Kim, Byung-In
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05b
    • /
    • pp.75-81
    • /
    • 2003
  • This study evaporates ZnO layer thickness differently with RF sputtering method on Si Wafer(n-100). This study is performed to examine the characteristics of photon energy and dielectric loss according to the thickness of ZnO and increase the reliability and reproduction of ZnO thin film. It is confirmed that the variation of electric Permittivity by frequency is resulted from the formation of particles within thin film, the particle size and the polarization on grain boundary. Peak of electric Permittivity value of thin film has slower and less value in early low wavelength by the coulomb force involved in carrier combination according to the increase of frequency. Reversal of electric Permittivity values is induced by dipole polarization shown in the dielectric of thin film. Complex electric constant $({\varepsilon}_1{\varepsilon}_2)$ has larger peak values as it’s thickness is thinner and then it is larger according to the increase of frequency. Electric Permittivity by photon energy has large value in imaginary number and is reduced exponentially by the increase of carrier density according to that of photon energy.

  • PDF

The Photon Energy Characteristics of ZnO Thin Film Fabricated by RF Sputtering (RF Sputtering으로 제작한 ZnO 박막의 Photon Energy 특성)

  • Kim, Byung-In;Kim, Won-Bae;Chung, Seong-Gyo;Kim, Duck-Tae;Choi, Young-Il;Kim, Hyung-Gon;Song, Chan-Il
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.73-79
    • /
    • 2002
  • This study evaporates ZnO layer thickness' differently with RF sputtering method on Si Wafer(n-100). This study is performed to examine the characteristics of photon energy and dielectric loss according to the thickness of ZnO and increase the reliability and reproduction of ZnO thin film. It is confirmed that the variation of electric Permittivity by frequency is resulted from the formation of particles within thin film, the particle size and the polarization on grain boundary. Peak of electric Permittivity value of thin film has slower and less value in early low wavelength by the coulomb force involved in carrier combination according to the increase of frequency. Reversal of electric Permittivity values is induced by dipole polarization shown in the dielectric of thin film. Complex electric constant $({\varepsilon}_1,{\varepsilon}_2)$ has larger peak values as it's thickness is thinner and then it is larger according to the increase of frequency. Electric Permittivity by photon energy has large value in imaginary number and is reduced exponentially by the increase of carrier density according to that of photon energy.

  • PDF

Long Term Average Spectral Analysis for Acoustical Discrimination of Korean Nasal Consonants (한국어 비음의 음향학적 구분을 위한 장구간 스펙트럼(LTAS) 분석)

  • Choi, Soon-Ai;Seong, Cheol-Jae
    • MALSORI
    • /
    • no.60
    • /
    • pp.67-84
    • /
    • 2006
  • The purpose of this study is to find some acoustic parameters on frequency domain to distinguish the Korean nasals, $/m,\;n,\;{\eta}/$ from each other. The new parameters are devised on the basis of LTAS (Long Term Average Spectrum). The maximum peak amplitude and the relevant formant frequency are measured in low and high frequency range, respectively. The frequency of spectral valley and its energy level are also obtained in the specific frequency range of the spectrum. Spectral slope, total energy value in specific frequency range, statistical distribution of spectral energy like centroid, skewness, and kurtosis are suggested as new parameters as well. The parameters that show statistically significant differences across nasals are summerized as follows. 1) in syllable initial positions: the total energy value from 1,500 to 2,200 Hz(zeroENG); 2) in syllable final positions: the peak amplitude of the first formant(peak1_a), the formant frequency with maximum peak amplitude from 4,000 to 8,000 Hz(peak2_f), the maximum peak amplitude of the formant frequency from 4,000 to 8,000 Hz(peak2_a), and the total energy value from 1,500 to 2,200 Hz(zeroENG).

  • PDF