• Title/Summary/Keyword: Energy Save Design

Search Result 147, Processing Time 0.025 seconds

A study on mold design for microscopic bubble-producing air diffusers and on mold manufacture (미세기포 발생 산기장치 금형의 설계와 제작에 관한 연구)

  • Lee, Eun-jong;Choi, Kye-kwang;Kim, Sei-hwan
    • Design & Manufacturing
    • /
    • v.7 no.1
    • /
    • pp.50-54
    • /
    • 2013
  • Sewage treatment plants are energy hogs. Among many, aeration systems account for 40-50 percent of the total energy use. To save energy, strengthening oxygen transfer characteristics is necessary. In order to do so, microscopic bubble-creating equipment is a prerequisite. This study focuses on microscopic bubble-producing air diffuser manufacture to save energy and enhance oxygen transfer.

  • PDF

A Software Development of Energy Consumption for HVAC System of Building (건물에너지 소비량 해석 소프트웨어 개발)

  • Kim B. H;Jo S. B;Kim J. P
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.19 no.2
    • /
    • pp.67-81
    • /
    • 1990
  • The objective of this is to develop a practical software package to calculate annual energy consumption of HVAC (Heating Ventilating, and Air Conditioning) System in a building. It can quickly estimate loads and energy consumption, and have a function of economic analysis through the estimation of operating cost. Techniques of save energy consumption used in a building are necessary from the stage of design process to operation. The single most significant task is on HVAC Systems. Their installation costs, and related operating costs have enormous influence upon initial and maintenance costs. HVAC designers and engineers now have a wide variety of software choices available, but only a few of them have been developed in this country and no source program has been disclosed. Neither load culculation nor estimation of energy consumption is systematically made by the domestic HVAC design firms. Even though computer improved over the years with a trend of large scale load calculation and system selection through simulaion, the utilization of software nowadays does not make good progress due to lack of working environment. Therefore, it is necessary to develop a practical software package with which load calculation can be made with ease and kind manner. This study concerns the development of a software package which makes it possible to design HVAC system and save energy consumption in operation. The algorithm used in this program is a Modified Bin Method widely known as a simplified energy analysis means.

  • PDF

A study of energy saving and long conservation in construction of rock store house (암반 저장창고 건설을 통한 에너지 절감과 장기보존에 대한 연구)

  • 최예환;채경희
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.210-216
    • /
    • 1998
  • The most important thing to consider in cold store design are to save cooling energy consumption and to keep goods freshly. Specially there are many efforts to save energy with cold store in Korea. A building energy simulation program should be used to optimally select a cooling system to match the criteria of cooling rate and storage rate in a given cool crop storage building and HVAC system. The low maintenance costs, high degree of safety and environmental impacts are also favouring the underground solution. There are obviously a lot of possibility for cost-effective storage of cooled or frozen goods or liquids in ground water rock.

  • PDF

A Study on the User and Location Awareness Technology Applied Dimming Lighting Control System to Save Energy (에너지 저감을 위한 사용자 및 위치인식 기술 적용 디밍 조명제어 시스템 연구)

  • Choi, Kihyun;Kim, Yongseong;Lee, Henagwoo;Seo, Janghoo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.1
    • /
    • pp.14-23
    • /
    • 2015
  • Although research and technology developments have recently increased to save lighting energy within buildings, such research and technology development are judged to be unsuitable for energy savings since they are limited in the sense that the application of the technology is fragmented. This study proposes a user and location awareness technology applied to dimming lighting control system and verified the effectiveness of energy savings by building a test bed. The results were as follows : 1) This study suggested a user and location awareness technology applied to dimming lighting control system. 2) The system shows 96.6% and 82.8% energy saving rates, respectively, on the basis of one user, compared to an on/off lighting control and the user and location awareness technology applied to on/off lighting control system. 3) The energy consumption of the user and location awareness technology applied to on/off lighting control system and the user and location awareness technology applied to dimming lighting control system increased to 96.6%, 88.3%, and 59.6% and 82.8%, 85.0%, 51.5%, respectively, on the basis of one, two, and three users, compared to the on/off lighting control system. This study confirmed the energy saving performance of the user and location awareness technology applied to the dimming lighting control system through performance evaluation. In this regard, further study needs to be undertaken to evaluate the performance at night time.

A Sutdy on the Apllicability of the Energy Pile System on Substation (변전소 구조물의 에너지파일 시스템 적용성 연구)

  • Lee, Daesoo;Oh, Gidae;Lee, Kangyul
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.198-198
    • /
    • 2011
  • Cooling and Heating system using Geothermal energy in the country has shown rapid development in the research and business field during about 10 years. However, like other renewable energy sources, high initial construction cost is acting as an obstacle to apply widely. Therefore Energy pile system(Heat Exchanger inserted inside the structure pile) that can save about 25 % initial construction cost has been studied in European countries and recently being studied in our country. Therefore, KPECO(Korea Electric Power Corporation) is also studying energy pile system to improve cooling & heating system in substation that install about 200 pile. KPECO is aimed to make energy pile design, construction and maintenance standards because substation has good applicability. In this study, we studied to make new grout material and design program to make optimized design & counstruction method of energy pile system. And planing to peform field test for energy pile system in a 154 kV substation to obtain long-term behavior and efficiency of the system.

  • PDF

The measurement study on the airtightness of dwellings based on the passive design (패시브 디자인을 적용한 주택의 기밀성에 관한 실측 사례 연구)

  • Lee, Tae-Goo;Yun, Doo-Young
    • KIEAE Journal
    • /
    • v.13 no.2
    • /
    • pp.13-20
    • /
    • 2013
  • Today, the world energy consumption in buildings occupies more than 30%. In our country, the energy consumption in buildings also occupies 25% of the entire national energy consumption. With the increasing demand of energy saving in architectural fields, there is a more interest in low-energy construction. For these low-energy housings, our country is planning to apply the energy-saving design standards at the level of passive houses in 2017. However, there is still a limitation in energy saving only with the standards on the performance of envelope in buildings. This means that unless a building is airtight even though it was well-insulated, cooling and heating energy consumption will increase due to the infiltration and leakage. Therefore, this study aims to make a comparative analysis of airtight performance by conducting a blower door test on the housings applied with passive designs, analyze the reasons why most houses fall short of the airtightness standards, and complement the airtightness problems in the inadequate parts of the buildings in order to save building energy.

Design of Controllers for Battery Energy Storage System (2차전지 전력저장시스템의 제어기 설계)

  • 한석우;전윤석;최규하;목형수
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.431-434
    • /
    • 1999
  • This paper presents design of controllers for battery energy storage system. The proposed battery energy storage system can be controlled to operate in the power conditioning mode or the inverter mode. The operation of this mode further divided into three cases: (a) in the peak load period, the load power supplied from the utility is minimized as far as possible; (b) in the off-peak load period, the utility supplies power to the load and charges the battery bank with automatic charging control; (c) in the medium load period, to save battery energy the real power flow out of the battery energy storage system is minimized. Besides, in all cases, the proposed battery energy storage system also automatically compensates the harmonics, subharmonics and reactive power factor in the utility side are much improved. Simulation results are presented by the effectiveness of the proposed controllers for battery energy storge system.

  • PDF

A Study on the Optimum Design for Energy Saving of an Auto Transmission Part (자동변속기용 부품의 에너지 절감을 위한 최적 설계 연구)

  • Lee, H.S.;Kim, T.H.;Kim, S.H.;Hong, E.C.;Lee, J.H.
    • Transactions of Materials Processing
    • /
    • v.24 no.3
    • /
    • pp.181-186
    • /
    • 2015
  • Many in the industrial world that consume high amounts of energy are trying to reduce energy when manufacturing their products. Energy saving during manufacturing is a cost reduction. Reduced cost is necessary for profit improvement. The Piston Under Drive Brake used in the current study is an automotive transmission part. The original machining after hot forging was changed to machining after cold forging of a plate in order to save energy and cost. Two extrusion shapes along the outer diameter caused decreased tool life because of the interrupted cut during turning. Therefore, a thickness reduction of two extrusion areas in the outer diameter was needed. The current study suggests an effective way to reduce the thickness of interrupted cut by using progressive blanking.

Adaptive Streaming System for Improving Energy Efficiency over IEEE 802.11e U-APSD (IEEE 802.11e U-APSD 환경에서 에너지 효율 향상을 위한 적응적인 스트리밍 시스템)

  • Lee, Sung-Hee;Chung, Kwang-Sue
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.11
    • /
    • pp.1066-1070
    • /
    • 2010
  • In wireless network, energy efficiency is an important design consideration for continuous multimedia streaming service. This paper proposes a new streaming system, called BACASS (Buffer-Aware and Content-Aware Streaming System) that working on the 802.11e U-APSD (Unscheduled Automatic Power Save). The BACASS leads the DP (Doze Period) of U-APSD for improving energy efficiency by utilizing the PSNR based on content-aware and client buffer occupancy that is hinged on a network-aware streaming system using SVC. The simulation results demonstrate the effectiveness of the proposed streaming system.

HVAC System For Highriser Residential Bilding (기획특집 - 초고층 설비설계사례)

  • Noh, Suk-Nam
    • Journal of the Korean Professional Engineers Association
    • /
    • v.42 no.5
    • /
    • pp.32-36
    • /
    • 2009
  • This project located in IFEZ(Incheon Free Economic Zone) is the first central heating and cooling type for high-rise residential building in korea. The design was performed as the joint venture between Cosentini from U.S.A and wooowon, and our design concept was to save energy. LEED application from USGBC is going on in progress for the first residential building in korea. Careful attention was paid from schematic design for not a durability of structural and architectural, but also durability and safety of M.E.P.

  • PDF