• Title/Summary/Keyword: Energy Management System (EMS)

Search Result 153, Processing Time 0.047 seconds

Target Operation Voltage Guidelines Considering Voltage Level in Each Voltage Control area by Applying Optimization Technique Through EMS Data Observation (EMS data 분석 및 최적화 기법을 적용한 제어지역별 목표운전전압 제안)

  • Sung, Ung;Kim, Jae-Won;Kim, Tae-Gyun;Lee, Byong-Jun;Jung, Eung-Soo;Cho, Jong-Man
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.671-678
    • /
    • 2009
  • This paper presents target operation voltage guidelines of each voltage control area considering both voltage stability and economical efficiency in real power system. EMS(Energy Management System) data, Real-time simulator, shows not only voltage level but lots of information about real power system. Also this paper performs optimal power flow calculation of three objective functions to propose the best target operation voltage. objective function of interchange power flow maximum and active power loss minimization stand for economical efficiency index and reactive power reserve maximum objective unction represents stability index. Then through simulation result using optimazation technique, the most effective objective function is chosen. To sum up, this paper divides voltage control area into twelve considering electric distance characteristics and estimate or voltage level by the passage of time of EMS peak data. And through optimization technique target operation voltage of each voltage control area is estimated and compare heir result. Then it is proposed that the best scenario to keep up voltage stability and maximize economical efficiency in real power system.

Linked operation between energy management system(EMS) and market operation system(MOS, CBP) (계통운영시스템(EMS)과 시장운영시스템(MOS,CBP)간 연계운영)

  • Park, Bong-Yong;Kim, Myung-Woong;Ahn, Jae-Seung;Kim, Min-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.547_548
    • /
    • 2009
  • 전력거래소에서 전력계통 및 전력시장 운영을 위해 도입한 핵심시스템은 EMS, MOS, CBP 이다. 이 세개 시스템은 각각 고유의 기능을 가진 별도의 시스템으로 구축되었다. 우리나라의 전력시장이 발전경쟁단계에 머무르면서 당초 양방향전력시장용으로 도입된 MOS시스템이 활용되지 못함에 따라 MOS시스템의 실시간 급전기능을 활용해 전력계통 운영의 안정성 및 경제성 향상을 꾀하고자 이 세 개의 시스템을 2006년 10월부터 연계 운영하고 있다. 이를 위해 CBP입찰값을 MOS의 입찰형식으로 변환하기위한 CBP-MOS 입찰변환시스템, 실시간 수요예측을 위한 수요예측 프로그램, MOS와 EMS를 일괄적으로 연계하기 위한 연계Mode, 각 발전기 운전원들에게 발전기의 급전계획값 및 실시간 운전현황을 전송하기 위한 급전지시시스템(MX) 및 전반적인 시스템 연계운영을 종합적으로 감시하기 위한 종합감시시스템 등을 개발하여 운영하고 있다.

  • PDF

The Study on Implementation and Application of Remote Energy Management System Using Com Server (COM SERVER 기반 원격소 급전자동화시스템 구현 및 적용에 관한 연구)

  • Kwak, Hee-Jin;Hong, Soon-Gap;Lee, Jong-Ku;Ryu, Young-Mo;Kim, Hyun-Il
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.103_104
    • /
    • 2009
  • We have supervised the conditions of facilities of Hydro power plant using SCADA system. and we have operated the EMS after joined in Electricity Market. In this paper, I introduce EMS of K-WATER and afterwards, this paper will be able to help us to make a decision when we install or revise EMS.

  • PDF

A Development of the On-line Maintenance and Management System for the HVAC system Using IT (IT를 활용한 공조설비의 온라인 유지관리시스템 개발)

  • Lee, Tae-Won;Kim, Yong-Ki;Kang, Sung-Ju;Woo, Nam-Sub
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.48-53
    • /
    • 2008
  • The performances of the building service equipment relay on the individual superintendent's share for the assessment of performance, fault detection, deterioration diagnosis of the building service equipment. A major use of building energy management system(BEMS) is for monitoring plant and building's energy consumption. National building management system (N-BMS) presented in this study links buildings into a network group in order to monitor and control the buildings. How to construct the N-BMS was considered to save energy resource and to conserve performance of building service equipment. The FEMIS, facility, energy/environmental management & information system, for building service offer management process integrated with BAS, FMS and EMS and so on.

  • PDF

Development of data conversion system between MOS & EMS (이기종 컴퓨터(MOS/EMS)간 데이터 자동변환시스템 개발)

  • Lee, Kang-Jae;Choi, Bong-Soo;Kim, Tae-Eon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1863-1864
    • /
    • 2008
  • 한국전력거래소에서 운영중인 EMS(Energy Management System)와 MOS(Market Operation System) 설비는 각각 Alstom사와 ABB사에 의해 우리나라의 전력계통 특성에 맞게 제작되어 공급된 전력계통과 전력시장의 운영을 자동화한 시스템이다. EMS는 전력계통 감시와 효율적인 운영을 위해 전력계통을 모델링한 데이터를 활용하며, MOS는 실시간 급전계획 수립을 위한 기반자료로 전력계통을 모델링한 데이터를 사용하게 된다. 그러나, 대한민국 전력산업의 핵심인 두 시스템은 시스템 설계 방식 및 DB 구조가 상이하여 전력계통의 신.증설 및 변경 시 동일한 데이터를 양 시스템에 각각 따로 구축, 운영해야하는 실정이다. 이에 따라 DB작업을 위한 자료 준비부터 입력, 수정, 검증 등 모든 과정에 중복된 관리가 이루어지고 있다. 중복 관리는 양 시스템 간 DB의 주요 데이터 특성 및 명칭이 상이하여 일률적인 관리가 어렵고, 시스템별 특성 및 운영노하우가 없이는 인적실수에 의한 입력오류 개연성이 폭넓게 존재하는 등 현 상황에서 피할 수 없는 현실이었다. EMS와 MOS 시스템 중 최소한 개의 시스템을 전면 재구축하지 않으면 해결되지 않을 본 문제를 해소하기 위하여 전력거래소는 특정 시스템에 구축된 데이터를 변환알고리즘을 통해 나머지 하나의 시스템에 자동 구축할 수 있는 시스템을 개발하여 활용하고자 한다. 이것이 바로 EMS에 입력되어 정확성이 검증된 계통데이터를 추출하여 MOS의 데이터 형식으로 변환하고, 변환된 데이터를 MOS시스템에 자동으로 입력할 수 있는 MOS/EMS 데이터 자동변환시스템이다.

  • PDF

Evaluation of Edge-Based Data Collection System through Time Series Data Optimization Techniques and Universal Benchmark Development (수집 데이터 기반 경량 이상 데이터 감지 알림 시스템 개발)

  • Woojin Cho;Jae-hoi Gu
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.1
    • /
    • pp.453-458
    • /
    • 2024
  • Due to global issues such as climate crisis and rising energy costs, there is an increasing focus on energy conservation and management. In the case of South Korea, approximately 53.5% of the total energy consumption comes from industrial complexes. In order to address this, we aimed to improve issues through the 'Shared Network Utility Plant' among companies using similar energy utilities to find energy-saving points. For effective energy conservation, various techniques are utilized, and stable data supply is crucial for the reliable operation of factories. Many anomaly detection and alert systems for checking the stability of data supply were dependent on Energy Management Systems (EMS), which had limitations. The construction of an EMS involves large-scale systems, making it difficult to implement in small factories with spatial and energy constraints. In this paper, we aim to overcome these challenges by constructing a data collection system and anomaly detection alert system on embedded devices that consume minimal space and power. We explore the possibilities of utilizing anomaly detection alert systems in typical institutions for data collection and study the construction process.

Design and Implementation of EMS for Real-Time Power Generation Control of Wind Farm Based on Wake Effect Optimization (후류 영향 최적화 기반 실시간 풍력발전단지 발전 제어용 EMS의 설계 및 구현)

  • Kim, Joon-Hyoung;Sung, Ki-Won;Jung, Sung-Hwan
    • Journal of Korea Multimedia Society
    • /
    • v.25 no.8
    • /
    • pp.1097-1108
    • /
    • 2022
  • This paper aimed to design and implement an EMS for real-time power generation control based on wake effect optimization of wind farm, and then to test it in commercial operating wind farm. For real-time control, we proposed the wake band-based optimization and setting the wake effect distance limit, and when the wake effect distance limit was set to 7D in the actual wind farm layout, the calculation time was improved by about 93.94%. In addition, we designed and implemented the script-based EMS for flexible operation logic management in preparation for unexpected issues during testing, and it was installed and tested on a wind farm in commercial operation. However, three issues arose during the testing process. These are the communication interface problem of meteorological tower, the problem of an abnormal wake effect, and the problem of wind turbine yaw control. These issues were solved by modifying the operation logic using EMS's script editor, and the test was successfully completed in the wind farm in commercial operation.

Implementation of Communication Protocol between Control Centers using ICCP (ICCP를 사용한 전력센터간의 통신 프로토콜 구현)

  • Jang, Kyung-Soo;Chang, Byung-Wook;Hahn, Kyung-Duk;Shin, Dong-Ryeol
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.12
    • /
    • pp.3910-3922
    • /
    • 2000
  • Current power systems are distributed geographically and operated in the form of Energy Management System(EMS)/ Supervision Control and Data Acquisition(SCADA) with the aid of computers and communications. Recently a variety of utilities have had interests in using inforrration technology to bring the efficiency and low operational costs. There is also a trend to integrdte the production, transmission, distribution and management/control of power into one and unified distributed system. To this end, Electric Power Hesearch Institute(EPRI) announced a new standard communication protocol called Inter-Control Center Protocol(ICCP).ICCP specifies the use of Manufacturing Message Specification(MMS) for services required by rccr in application layer and supports the communications between heterogeneous control centers. This paper presents the characteristics of MMS,ICCP and their relationship. Futherrnore, we implement the basic functional blocks of ICCP using MMS services under TCI/IP environments. Finally, we model a simple power system and apply the rccp protocol to this system in a window-based scheme, and finally show the operation and validation of this protocol.

  • PDF

Kalman-Filter Based Static Load Modeling of Real Power System Using K-EMS Data

  • Lee, Soo-Hyoung;Son, Seo-Eun;Lee, Sung-Moo;Cho, Jong-Man;Song, Kyung-Bin;Park, Jung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.3
    • /
    • pp.304-311
    • /
    • 2012
  • So far, the importance for an accurate load model has been constantly raised and its necessity would be further more emphasized. Currently used load model for analysis of power system in Korea was developed 10 years ago, which is aggregated by applying the statistically estimated load compositions to load models based on individual appliances. As modern appliances have diversified and rapidly changed, the existing load model is no longer compatible with current loads in the Korean power system. Therefore, a measurement based load model is more suitable for modern power system analysis because it can accurately include the load characteristics by directly measuring target load. This paper proposes a ZIP model employing a Kalman-filter as the estimation algorithm for the model parameters. The Kamlan-filter based parameter identification offers an advantage of fast parameter determination by removing iterative calculation. To verify the proposed load model, the four-second-interval real data from the Korea Energy Management System (K-EMS) is used.

Methodology for improving real-time load forecast program in the MOS-EMS interconnection (MOS-EMS연계활용을 위한 실시간 수요예측 프로그램 기능개선을 위한 방법론)

  • Kim, K.I.;Kim, D.J.;Kim, K.C.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.349-350
    • /
    • 2006
  • 정부의 배전분할 유보결정에 따라 전력거래소에서는 현행 발전경쟁시장의 효율성 향상을 위한 많은 사업을 추진하고 있다. 그중 우선적으로 추진하였던 사업이 도매전력시장을 대비해 구축한 시장운영시스템(MOS; Market Operation System)을 현행 계통운영을 담당하고 있는 급전 자동화시스템(EMS; Energy Management System)과의 연계활동이다. 이는 시장운영시스템(MOS)에 내재되어 있는 최첨단 기능중에서 일부를 현행 전력시장에 적용함으로써 계통운영의 효율성 향상뿐만 아니라 계통운영기술을 선진화하는 것이다. 특히, 기존 급전시스템에 비해 가장 두드러지는 점은 발전기들에 대한 에너지 및 예비력 급전계획을 사전적으로 5분단위로 최적화하여 수립하고 이를 발전기들에게 송신함으로써 경제적이며 안정적인 전력계통운영을 가능하게 해 줄 수 있는 것이다. 이를 가능하게 하기 위해서는 바로 정확한 미래 수요수준의 결정이 필수불가결한 요소이다. 따라서 본 논문에서는 MOS-EMS 연계활용에서의 실시간 수요예측의 중요성과 기존 제작사의 알고리즘과 국내 전력수요특성간의 불일치점 그리고 이를 해결하고자 모색했던 방안들에 대하여 설명하고자 한다.

  • PDF