• Title/Summary/Keyword: Enclosed pig house

Search Result 17, Processing Time 0.022 seconds

Effects of Ventilation Systems on Interior Environment of the Growing-finishing Pig House in Korea (육성$\cdot$비육돈사 내에서 환기형태별 환경조사 연구)

  • Song J. I.;Yoo Y. H.;Jeong J. W.;Kim T. I.;Choi H. C.;Kang H. S.;Yang C. B.;Lee Y. Y.
    • Journal of Animal Environmental Science
    • /
    • v.10 no.2
    • /
    • pp.93-100
    • /
    • 2004
  • An experiment was conducted to establish comparison of ventilation efficiency in an enclosed and conventional growing-finishing pig house. The experimental pigs were in winter and summer. The main results of the experiment are as follows : Then the air from planar slot inlet the pig house flow out through the sidewall outlet operated by exhaust fan(Gl). The second structure has an air input through the circular duct inlet are plated side the juncture of the entering wall and the air into the pig house flow out through the chimney and pit outlet are operated by exhaust fan(G2). Through the air into relay fan the pig house flow out through the curtains in sidewall(G3). Similarly, air comes in through the circular duct inlet are placed the air into the pig house flow out through the curtains in sidewall (G4). Air flow rate on the floor level which is the low part of pen and the living area of pigs in the G2 and G4 system during winter was measured at 0.2 to 0.3 m/s at the 0.5 to 0.6 m/s at the maximum ventilation efficiency. As for the results of detrimental gas(ammonia) concentration ratio analysis, while G2 and G4 system sustained of summer 13.3 $\~$ 16.6 ppm, winter 14.0 $\~$ 14.6 ppm level, Gl and G3 system sustained of summer 14.6 $\~$ 20.3 ppm, winter 20.3 $\~$ 25.0 ppm, and the latter one is lower than that of the G1 and G3 system.

  • PDF

An Intelligent Ventilation System in an Enclosed Nursery Pig House (지능형 돈사 환기 제어 시스템)

  • Kim, Seok-hun;Lee, Sae-bom;Lee, Geon-won;Im, Kwang-hyuk
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2014.07a
    • /
    • pp.429-430
    • /
    • 2014
  • 본 논문은 돈사 내부의 환기부를 연속적으로 작동한 상태에서 환기부의 입기팬 및 배기팬의 회전수를 감소시키거나 증가시킴으로서 축사 내부로 유입되는 환기량을 조절하고, 이에 따라 환기 운영 시에 축사 내부의 온도 편차를 최소화함과 동시에 유해가스에 의한 돈사 내 공기오염을 방지할 수 있는 지능형 돈사 환기 제어 시스템 설계에 관한 연구이다. 본 시스템에는 온도 측정 데이터를 일정간격으로 저장하고, 저장된 온도 변화의 특성을 추출하여 지능적으로 돈사의 상태를 최적으로 유지할 수 있는 지능형 환기 제어 모델, 사용자의 연령 및 상황을 고려한 가시적이고 직관적인 사용자 위주의 인터페이스 설계가 포함된다.

  • PDF

Characterization of Bacillus thuringiensis Having Insecticidal Effects Against Larvae of Musca domestica

  • Oh, Se-Teak;Kim, Jin-Kyu;Yang, Si-Yong;Song, Min-Dong
    • Journal of Microbiology and Biotechnology
    • /
    • v.14 no.5
    • /
    • pp.1057-1062
    • /
    • 2004
  • The entomopathogenic bacterium Bacillus thuringiensis is the most widely used biopesticide. Insecticidal proteins, coded by genes located in plasmids, form typical parasporal, crystalline inclusions during sporulation. We isolated a Bacillus thuringiensis strain having insecticidal activity against larvae of the house fly (M. domestica) from the soils at a pig farm in Korea, and named it Bacillus thuringiensis SM. The culture filtrate from Bacillus thuringiensis SM showed strong lethality (83.3%) against M. domestica larvae. The parasporal crystal is enclosed within the spores' outermost envelope, as determined by transmission electron microscopy, and exhibited a bipyramidal form. The crystal proteins of strain SM consisted of five proteins with molecular weights of approximately ~130, ~80, ~68, ~42, and ~27 kDa on a 10% SDS-PAGE (major band, a size characteristic of Cry protein). Examination of antibiotic resistance revealed that the strain SM showed multiple resistant. The strain SM had at least three different plasmids with sizes of 6.6, 9.3, and 54 kb. Polymerase chain reactions (PCRs) revealed the presence of cry1, cry4A2, and cry11A1 genes in the strain SM. The cry1 gene profile of the strain SM appeared in the three respective products of 487 bp [cry1A(c)], 414 bp [cry1D], and 238 bp [cry1A(b)]. However, the strain SM has not shown the cry4A2 md cry11A1 genes. In in vivo toxicity assays, the strain SM showed high toxicity on fly larvae (M. domestic) [with $LC_{50}$ of 4.2 mg/ml, $LC_{90}$ of 8.2 mg/ml].

Estimation of THI Index to Evaluate Thermal Stress of Piglets in Summer Season (하절기 자돈 고온 스트레스 평가를 위한 THI 지수 모의)

  • Ha, Taehwan;Kwon, Kyeong-seok;Lee, In-bok;Kim, Rack-woo;Yeo, Uk-hyeon;Lee, Sangyeon;Choi, Hee-chul;Kim, Jong-bok;Lee, Jun-yeob;Jeon, Jung-hwan;Woo, Saemee;Yang, Ka-young
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.60 no.4
    • /
    • pp.113-122
    • /
    • 2018
  • Thermal stress of pigs causes decreased feed consumption and weight gain rate, immunosuppression, reproductive disorders, and increased mortality. The concept of the temperature-humidity index (THI) has been widely used to evaluate the degree of thermal stress of pigs. However, use of this concept is strongly restricted for animals living in the enclosed facilities. In this study, Building Energy Simulation (BES) technique was used to realize the energy flow among outside weather conditions, building materials, and animals. Especially, mechanisms of sensible and latent heat generation from pigs according to surrounding air temperature and their weight were designed to accurately evaluate the THI values inside the pig house. The THI values computed by the BES model were compared to those calculated by method of the report (NIAS, 2016), the model of this study predicted the start date of heat stress about 9~76 days earlier compared to the NIAS model. Results of the BES model also showed higher frequencies of the THI above the THI threshold for pigs, indicating that conventional model has a possibility of underestimating the degree of heat stress of pigs.

The Effects of Confined Rates Side Wall of Pen for Evacuation Behaviors of Pigs (돈방 측벽마감율이 돼지의 배분 특성에 미치는 영향)

  • 송준익;최홍림
    • Journal of Animal Environmental Science
    • /
    • v.7 no.3
    • /
    • pp.147-154
    • /
    • 2001
  • An experiment was conducted to examine environmental influences upon the behavioral pattern of pigs. The resting areas of an enclosed growing-finishing pig house were checked in two seasonal ventilation systems, and the excretion habit of pigs influenced by the different closing rates (50, 75 and 100%) of side walls of pens was surveyed. 1. The excretion habit of pigs was not influenced by temperature, humidity and the flow speed of running air as they excreted in a fixed area of the side walls. However, the lighting effects on the excretion habit was observed because pigs excreted in the darkest area of the pig pen. 2. The accumulated height and width of feces showed 10 and 30 cm; 5 and 25cm; and 3 and 20cm for 50, 75 and 100% of closing rates of side walls, respectively. It indicates that pigs excrete all over the floor in the pen with 100% closed side walls. 3. Ammonia concentrations of the resting areas on the pen floor were determined to 4.2, 5.1 and $5.8mg/{\ell}$ for 50, 75 and 100% of closing rates of side walls, respectively. It indicates that the ammonia concentration was highest in the pen with 100% closed side walls. Thus, the high ammonia concentration of the resting areas could be reduced by illuminating the darker areas with relation to the excretion habit. 4. The flow speed of running air was likely the biggest factor influencing the resting areas of pigs; pigs took a rest at the place of 0.04 m/s air flow speed point during midwinter, and at the place of 0.24 m/s air flow speed point during midsummer.

  • PDF

The Effect of Vantilation System Renovation from Winch Style to Non-window Style for Swine Barn (개방돈사의 무창돈사형 환기시설 개선 효과)

  • Song, J.I.;Jean, J.H.;Park, H.K.;Kang, H.S.;Choi, D.Y.;Kim, D.H.;Park, K.H.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.2
    • /
    • pp.109-114
    • /
    • 2010
  • In South Korea, mora than 90% of swine barns had open-style side wall by winch operation, and less than 5% of swine barns were semi-windowless or windowless style. The aisle ventilation system of the barn was changed to roof-wall ventilation system, and the width and the length of barns were 10~12 m and 30~50 m, respectively. The width of aisle satisfying energy save was 2~3 m. The re-modeled barns inhaled air through duct which was opened to aisle and exhaled through forced ventilation fans on the windowless wall which was accomplished by installing planks on the open wall. After remodelling, the culling ratio and energy cost were decreased from 11% (47 heads) to 3% (12 heads) and from 1,550,000 won to 730,000 won, respectively. Hence, re-modeled swine barns raising 400 heads could save 2,835,680 won during winter (from December to March).

Odor Emission Reduction from Enclosed Growing-Finishing Pig House Using Different Biofilter Media (무창 육성$\cdot$비육돈사에서의 Biofilter에 의한 악취제어 효과)

  • Song J. I;Kim T. I.;Choi H. C.;Yoo Y. H.;Jeong J. W.;Yeon K. Y.;Barroga Antonio;Yang C. B.;Kim D. H.;Lee J. W.
    • Journal of Animal Environmental Science
    • /
    • v.11 no.1
    • /
    • pp.55-60
    • /
    • 2005
  • This study was conducted to determine the odor reduction efficiency of a biofilter desist using different filter materials. The summary of results are as follows; 1. The airflow penetration rate of the different filter materials namely; rice straw, woodchips, rice hulls and sawdust were 0.72 m/s, 0.64 m/s, 0.48 m/s and 0.17 m/s, respectively. 2. The elimination of $NH_3$ gas was fastest in the rice hull at a rate of 4 mg/${\iota}$ followed by sawdust, woodchips and rice straw at 3 mg/${\iota}$, 3 mg/${\iota}$ and 7 mg/${\iota}$, respectively. 3. The filter material made of wood chips was able to eliminate the offensive gas known as $H_2S$ at a rate of 2.2 mg/${\iota}$ on the 7th day, 17.6 mg/${\iota}$ on the 21st day but decreased to 10.7 mg/${\iota}$ on the 36th day. In contrast, the filter material composed of sawdust had a continuous increase in the reduction of $H_2S$ at a rate of 12.3 mg/${\iota}$ on the 7th day, 18.3 mg/${\iota}$ on the 21st day and 20.1 mg/${\iota}$ on the 36th day. The above findings indicated that among the filter materials, sawdust was the most effective in absorbing $H_2S$. Airflow penetration rate can be related to $H_2S$ odor elimination efficiency as shown by the slowest airflow rate of sawdust which is only 0.17 m/s.

  • PDF