Effects of Ventilation Systems on Interior Environment of the Growing-finishing Pig House in Korea

육성$\cdot$비육돈사 내에서 환기형태별 환경조사 연구

  • Song J. I. (National Livestock Research Institute, R.D.A.) ;
  • Yoo Y. H. (National Livestock Research Institute, R.D.A.) ;
  • Jeong J. W. (National Livestock Research Institute, R.D.A.) ;
  • Kim T. I. (National Livestock Research Institute, R.D.A.) ;
  • Choi H. C. (National Livestock Research Institute, R.D.A.) ;
  • Kang H. S. (National Livestock Research Institute, R.D.A.) ;
  • Yang C. B. (National Livestock Research Institute, R.D.A.) ;
  • Lee Y. Y. (Sung Il)
  • Published : 2004.08.01

Abstract

An experiment was conducted to establish comparison of ventilation efficiency in an enclosed and conventional growing-finishing pig house. The experimental pigs were in winter and summer. The main results of the experiment are as follows : Then the air from planar slot inlet the pig house flow out through the sidewall outlet operated by exhaust fan(Gl). The second structure has an air input through the circular duct inlet are plated side the juncture of the entering wall and the air into the pig house flow out through the chimney and pit outlet are operated by exhaust fan(G2). Through the air into relay fan the pig house flow out through the curtains in sidewall(G3). Similarly, air comes in through the circular duct inlet are placed the air into the pig house flow out through the curtains in sidewall (G4). Air flow rate on the floor level which is the low part of pen and the living area of pigs in the G2 and G4 system during winter was measured at 0.2 to 0.3 m/s at the 0.5 to 0.6 m/s at the maximum ventilation efficiency. As for the results of detrimental gas(ammonia) concentration ratio analysis, while G2 and G4 system sustained of summer 13.3 $\~$ 16.6 ppm, winter 14.0 $\~$ 14.6 ppm level, Gl and G3 system sustained of summer 14.6 $\~$ 20.3 ppm, winter 20.3 $\~$ 25.0 ppm, and the latter one is lower than that of the G1 and G3 system.

본 연구는 우리나라에 건축되어져 있는 개방식 육성$\cdot$비육돈사나 무창식 육성$\cdot$비육돈사에 대한 효율 비교분석 연구가 없는 실정으로 개방식 육성$\cdot$비육돈사와 무창식 육성$\cdot$비육돈사의 환경효율을 검증하고자 하였다. 겨울철과 여름철로 나누어 실시한 실험결과는 다음과 같다. 1. 무창식 육성 비육돈사는 외부의 기온 변화가 심하더라도 돈사내부의 온도는 외부기온의 영향을 받지 않고 여름철 $31.8\~33.8^{\circ}C$, 겨울철 $17.9\~19.5^{\circ}C$를 유지하였으나 개방식 육성$\cdot$비육돈사는 여름철 32.1$\~$32.9, 겨울철 $15.8\~16.7^{\circ}C$를 유지하여 온도효율이 낮았다. 2. G2, G4 육성$\cdot$비육돈사는 돼지생활 공간(하부) 지점에서의 공기유속은 겨울철 최소환기($5\%$) 수준으로 하였을 때 0.2$\~$0.3 m/s 였으며, 여름철 최대환기($95\%$) 수준에서는 0.5$\~$0.6 m/s로 분포되어 여름철 및 겨울철의 육성$\cdot$비육돈사내 공기유속이 G1, G3 육성$\cdot$비육돈사보다 양호하였다. 3. 암모니아 농도를 측정한 바 G2, G4 육성$\cdot$비육돈사는 여름철 13.3$\~$16.6 ppm, 겨울철14.0$\~$~14.6 ppm으로 측정되었으며, G1, G3 육성$\cdot$비육돈사는 여름철 14.6$\~$20.3 ppm, 겨울철 20.3$\~$25 ppm을 유지하여 G1, G3 육성$\cdot$비육 돈사보다는 낮게 나타났다.

Keywords