• 제목/요약/키워드: Emission Image

검색결과 522건 처리시간 0.023초

Preliminary study of artificial intelligence-based fuel-rod pattern analysis of low-quality tomographic image of fuel assembly

  • Seong, Saerom;Choi, Sehwan;Ahn, Jae Joon;Choi, Hyung-joo;Chung, Yong Hyun;You, Sei Hwan;Yeom, Yeon Soo;Choi, Hyun Joon;Min, Chul Hee
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3943-3948
    • /
    • 2022
  • Single-photon emission computed tomography is one of the reliable pin-by-pin verification techniques for spent-fuel assemblies. One of the challenges with this technique is to increase the total fuel assembly verification speed while maintaining high verification accuracy. The aim of the present study, therefore, was to develop an artificial intelligence (AI) algorithm-based tomographic image analysis technique for partial-defect verification of fuel assemblies. With the Monte Carlo (MC) simulation technique, a tomographic image dataset consisting of 511 fuel-rod patterns of a 3 × 3 fuel assembly was generated, and with these images, the VGG16, GoogLeNet, and ResNet models were trained. According to an evaluation of these models for different training dataset sizes, the ResNet model showed 100% pattern estimation accuracy. And, based on the different tomographic image qualities, all of the models showed almost 100% pattern estimation accuracy, even for low-quality images with unrecognizable fuel patterns. This study verified that an AI model can be effectively employed for accurate and fast partial-defect verification of fuel assemblies.

Study on the PET image quality according to various scintillation detectors based on the Monte Carlo simulation

  • Eunsoo Kim;Chanrok Park
    • 핵의학기술
    • /
    • 제27권2호
    • /
    • pp.129-132
    • /
    • 2023
  • Purpose: Positron emisson tomography (PET) is a crucial medical imaging scanner for the detection of cancer lesions. In order to maintain the improved image quality, it is crucial to apply detectors of superior performance. Therefore, the purpose of this study was to compare PET image quality using Monte Carlo simulation based on the detector materials of BGO, LSO, and LuAP. Materials and Methods: The Geant4 Application for Tomographic Emission (GATE) was used to design the PET detector. Scintillations with BGO, LSO and LuAP were modelled, with a size of 3.95 × 5.3 mm2 (width × height) and 25.0 mm (thickness). The PET detector consisted of 34 blocks per ring and a total of 4 rings. A line source of 1 MBq was modelled and acquired with a radius of 1 mm and length of 20 mm for 20 seconds. The acquired image was reconstructed maximum likelihood expectation maximization with 2 iteration and 10 subsets. The count comparison was carried out. Results and Discussion: The highest true, random, and scatter counts were obtained from the BGO scintillation detector compared to LSO and LuAP. Conclusion: The BGO scintillation detector material indicated excellent performance in terms of detection of gamma rays from emitted PET phantom.

탄소나노튜브의 분산이 탄소나노튜브 캐소드의 전계방출 특성에 미치는 영향 (Effect of CNT Particle Dispersion in CNT Paste on Field Emission Characteristics in Carbon Nanotube Cathode)

  • 안병건;성명석;신허영;김동희;김태식;조영래
    • 한국재료학회지
    • /
    • 제14권11호
    • /
    • pp.807-812
    • /
    • 2004
  • The uniformity of emission mage and field emission properties of carbon nanotube(CNT) cathodes dependence on CNT particle dispersion were investigated for field emission displays. We used multi-walled carbon nanotubes (MWNTs) synthesized by CVD method as the field emitter materials. CNT dispersion in CNT ink was carried out by ultrasonication and shaking methods. According to CNT dispersion conditions, the uniformity of emission image and field emission properties of CNT cathodes were greatly affected. The smaller particles of filler materials and CNT powders provide the better properties of the CNT cathodes.

The Effect of Carbon Emission Disclosure on Firm Value: Environmental Performance and Industrial Type

  • HARDIYANSAH, Mohammad;AGUSTINI, Aisa Tri;PURNAMAWATI, Indah
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제8권1호
    • /
    • pp.123-133
    • /
    • 2021
  • This research aims to examine the effect of carbon emission disclosure on firm value and to reveal environmental performance and industrial type as the moderating variables. This study used 82 samples of companies listed on the Indonesia Stock Exchange (IDX) and receiving awards in the Indonesian Sustainability Reporting Award (ISRA) in 2014-2018. This study used a multiple linear regression analysis to test the hypotheses. The results showed that carbon emission disclosure had a positive and significant effect on firm value as carbon emission disclosure is a form of corporate concern on environment positively responded by the market and becomes the basis for investors to make their considerations in assessing the company sustainability. Besides, environmental performance and industrial type can strengthen the influence relationship of carbon emission disclosure on firm value since environmental performance was assessed based on ISO 14001 certification ensuring that the company has tried to preserve the environmental sustainability by creating a good environmental management system. Moreover, companies categorized into high profile industrial type have tried to change their unfavorable image and avoid lawsuits by performing carbon emission disclosure to gain positive responses from the market.

Drone 영상을 이용한 논 필지 볏짚 환원-동계 재배 확인 및 CH4 배출량 산정 (Estimation of Paddy CH4 Emissions through Drone-Image-Based Identification of Paddy Rice Straw Application & Winter Crop Cultivation)

  • 장성주;박진석;홍록기;홍주표;권채린;송인홍
    • 농촌계획
    • /
    • 제27권3호
    • /
    • pp.21-33
    • /
    • 2021
  • Rice straw management and winter crop cultivation are crucial components for the accurate estimation of paddy methane emissions. Field-based extensive investigation of paddy organic matter management requires enormous efforts however it becomes more feasible as drone technology advances. The objectives of this study were to identify paddy fields of straw application and winter crop cultivation using drone images and to apply for the estimation of yearly methane emission. Total 35 sites of over 150ha in area were selected nationwide as the study areas. Drone images of the study sites were taken twice during summer and winter in 2018 through 2019: Summer images were used to identify paddy cultivation areas, while winter images for straw and winter crop practices. Drone-image-based identification results were used to estimate paddy methane emission and compared with conventional method. As the result, mean areas for paddy, straw application and winter crop cultivation were 118.9ha, 12.0ha, and 11.3ha, respectively. Overall rice straw application rate were greater in Gyeonggi-do(20%) and Chungcheongnam-do(12%), while winter crop cultivation was greatest in Gyeongsangnam-do(30%) and Jeolla-do(27%). Yearly mean methane emission was estimated to be 226.2kg CH4/ha/yr in this study and about 32% less when compared to 331.8kg CH4/ha/yr estimated with the conventional method. This was primarily because of the lower rice straw application rate observed in this study, which was less than quarter the rate of 55.62% used for the conventional method. This indicates the necessity to use more accurate statistics of rice straw application as well as winter crop practices into paddy methane emission estimation. Thus it is recommended to further study to link drone technology with satellite image analysis in order to identify organic management practices at a paddy field level over extensive agricultural area.

p" Color Field Emission Displays Using Carbon Nanotube Emitters

  • Lee, N.S.;Park, W.B.;Kim, J.M.
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2000년도 제18회 학술발표회 논문개요집
    • /
    • pp.211-211
    • /
    • 2000
  • Carbon nanotubes (CNTs) have been spotlighted as one of promising field emission displays(FEDs). For the first time, to authors knowledge, we have developed the 9" color CNT-FEDs with the resolution of 240x576 lines. The 9" CNT-FEDs with diode-type and triode-type structures are presented. The well-dispersed CNT paste was squeezed onto the metal-patterned cathode glass. For the anode plate, the Y2O2S:Eu, ZnS:Ag,Cl low-voltage phosphors were printed for red, green, and blue colors, respectively. The vacuum-packaged panel maintained the vacuum level of 1x10-7 Torr. The uniform moving images vacuum-packaged panel maintained the vacuum level of 1x10-7 Torr. The uniform moving images were demonstrated at 2 V/um. High brightness of 800, 200, and 150cd/m2 was observed on the green, red, and blue phosphors at V/um, respectively. Field emission characteristics of a triode-type CNT-FED were simulated using a finite element method. the resultant field strength on the cathode was modulated by gate bias and emitted electrons were focused on the anode. A relatively uniform emission image was experimentally achieved at the 800V anode. A relatively uniform emission image was experimentally achieved at the 800V anode and the 50-180 V gate biases. Energy distribution of electrons emitted from CNTs was measured using an energy analyzer. The maximum peak of energy curve corresponded to the Fermi energy level of CNTs. The whole fabrication processed of CNT-FEDs were fully scalable and reproducible. Our CNT-FEDs has demonstrated the high potential of large-area and full-color applications with very low cost fabrication and low power consumption.

  • PDF

Analytic simulator and image generator of multiple-scattering Compton camera for prompt gamma ray imaging

  • Kim, Soo Mee
    • Biomedical Engineering Letters
    • /
    • 제8권4호
    • /
    • pp.383-392
    • /
    • 2018
  • For prompt gamma ray imaging for biomedical applications and environmental radiation monitoring, we propose herein a multiple-scattering Compton camera (MSCC). MSCC consists of three or more semiconductor layers with good energy resolution, and has potential for simultaneous detection and differentiation of multiple radio-isotopes based on the measured energies, as well as three-dimensional (3D) imaging of the radio-isotope distribution. In this study, we developed an analytic simulator and a 3D image generator for a MSCC, including the physical models of the radiation source emission and detection processes that can be utilized for geometry and performance prediction prior to the construction of a real system. The analytic simulator for a MSCC records coincidence detections of successive interactions in multiple detector layers. In the successive interaction processes, the emission direction of the incident gamma ray, the scattering angle, and the changed traveling path after the Compton scattering interaction in each detector, were determined by a conical surface uniform random number generator (RNG), and by a Klein-Nishina RNG. The 3D image generator has two functions: the recovery of the initial source energy spectrum and the 3D spatial distribution of the source. We evaluated the analytic simulator and image generator with two different energetic point radiation sources (Cs-137 and Co-60) and with an MSCC comprising three detector layers. The recovered initial energies of the incident radiations were well differentiated from the generated MSCC events. Correspondingly, we could obtain a multi-tracer image that combined the two differentiated images. The developed analytic simulator in this study emulated the randomness of the detection process of a multiple-scattering Compton camera, including the inherent degradation factors of the detectors, such as the limited spatial and energy resolutions. The Doppler-broadening effect owing to the momentum distribution of electrons in Compton scattering was not considered in the detection process because most interested isotopes for biomedical and environmental applications have high energies that are less sensitive to Doppler broadening. The analytic simulator and image generator for MSCC can be utilized to determine the optimal geometrical parameters, such as the distances between detectors and detector size, thus affecting the imaging performance of the Compton camera prior to the development of a real system.

FUV Emission-line Morphologies of the SNR G65.3+5.7

  • 김일중;선광일;민경욱
    • 천문학회보
    • /
    • 제35권1호
    • /
    • pp.70.1-70.1
    • /
    • 2010
  • We present the far-ultraviolet (FUV) emission line morphologies in the whole region of the supernova remnant G65.3+5.7 using the FIMS/SPEAR data. The morphologies of the C IV ${\lambda}{\lambda}1548$, 1551, $H2{\lambda}1608 $, He II ${\lambda}1640$, and O III] ${\lambda}{\lambda}1661$, 1666 lines appear to correlate clearly with the optical emission line images or the ROSAT X-ray (0.11-0.284 keV) image obtained in some of the previous studies. We found that a foreground dust cloud, resonant scattering, and incompleteness of radiative shocks have made the definite differences between the morphologies of the above FUV emission lines. We also present the FUV spectra and line intensities from a few sub-regions.

  • PDF

Wavelength Calibration Solution of VPH Grating Slitless Spectroscopy Image

  • O, Seong A;Shin, Suhyun;Im, Myungshin;Yoon, Yongmin;Kim, Yongjung
    • 천문학회보
    • /
    • 제43권1호
    • /
    • pp.68.2-68.2
    • /
    • 2018
  • Spectroscopic observations commonly use a slit or fiber; however, non-slit spectroscopy enables us to observe a larger number of targets in one frame of image. Hence, it has been adopted as an observational mode for observatories like HST and JWST. Slitless spectroscopy requires wavelength calibration solutions in order to distinguish and measure the absorption / emission lines from the spectra with high accuracy. We installed the Volume Phase Holographic (VPH) grating to SQUEAN camera on the McDonald 2.1m telescope and obtained images with spectral resolutions of ~ 100 and 200. In order to derive the wavelength calibration, we measured the distances between the 0th order images and spectral features of various quasars. The distances are converted to wavelengths using the known wavelengths of the emission lines. We tested several different methods of spectral extraction and peak estimation of emission lines. We will present the results for the wavelength calibration and suggest the reliable methods to find the solution.

  • PDF

단층진단법을 이용한 축대칭 부분예혼합 화염의 자발광 스펙트럼 해석에 관한 연구 (Tomographic Interpretations of Visible Emissions from the Axisymmetric Partially Premixed Flames)

  • 하광순;최상민
    • 대한기계학회논문집B
    • /
    • 제24권6호
    • /
    • pp.769-776
    • /
    • 2000
  • Visible spectral characteristics of cross-sectional emissions from a partially premixed methane/air and propane/air flames have been investigated. An optical train with a two-axis scanning mirror system was used to record line-of-sight emission spectra from 354nm to 618nm, and inversion technique was adapted to obtain cross-sectional emission spectra. By analyzing the reconstructed emission spectra, cross-sectional intensities of CH and $C_2$ radicals were separated from the background emissions. The blue flame edge and yellow flame edge were also obtained by image processing technique for edge detection with color photograph of flame. These edges were compared with radial distributions of CH, $C_2$ radicals and background emissions. The CH radicals were observed at blue flame edge. The background emissions were generated by soot precursor at upstream of flame and by soot at downstream of flame. The $C_2$ radicals in propane/air flame were observed more than those in methane/air flame.