• Title/Summary/Keyword: Emergency Monitoring System

Search Result 307, Processing Time 0.024 seconds

Study on the Liquid Rocket Engine Health Monitoring and Emergency Protection System (액체로켓엔진 상태진단/비상보호시스템 연구)

  • Kim, Seung-Han;Nam, Chang-Ho;Seol, Woo-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.178-182
    • /
    • 2007
  • This paper reviews on the LRE health monitoring and emergency protection system to protect test object engine system and engine test facility, in case of various fault occurrence at LRE testing. General composition and major technical consideration of LRE health monitoring system and emergency protection system are reviewed. Moreover, some application of LRE health monitoring/emergency protection system to development test of major LRE component such as turbopump testing, gas generator and combustion chamber test are reviewed.

  • PDF

The Proposed of Emergency Light Monitoring System by Self-Organization Radio Communication based on USN (USN기반 자율무선통신방식 비상등관리시스템 제안)

  • Choi, Jae-Myeong;Kang, Heau-Jo;Lee, Sang-Heon
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.2
    • /
    • pp.252-256
    • /
    • 2009
  • In this paper, the emergency light where is being scattered always inspection and will be able to manage from the management center. Is not interfered in data neck of a bottle actual condition and the data communication will be possible and the cluster monitor network will grow and uses establishes the emergency light monitoring system. Will not be interfered in location of emergency light and not to be will be able to establish the system. And the monitoring network there is by a destroyer and the communication relay system is born breakdown but the dead zone without condition of emergency light proposes the emergency light management system where the monitoring and management are possible.

  • PDF

Selection and Analysis of Operating Parameters for Condition Monitoring of Emergency Diesel Generator at Nuclear Power Plant (원자력발전소 비상디젤발전기 상태감시를 위한 운전인자 선정에 관한 연구)

  • Park, J.H.;Choi, K.H.;Lee, S.G.;Park, J.E.
    • Journal of Power System Engineering
    • /
    • v.11 no.3
    • /
    • pp.3-8
    • /
    • 2007
  • The emergency AC power supply system of the nuclear power plant is designed to supply the power to the nuclear reactor at the emergency operating condition. The safety function of the diesel generator at the nuclear power plant is to supply AC electric power to the plant safety system whenever the preferred AC power supply is unavailable. The reliable operation of onsite emergency diesel generator should be ensured by a conditioning monitoring system designed to maintain and monitor and forecast the reliability level of diesel generator. To do this kind of diesel generator condition monitoring we reviewed several operating factors and history of the wolsong unit 3 diesel generator and selected the proper conditioning monitoring operating factors.

  • PDF

The Implementation of Emergency Light Monitoring System by Intelligent Cluster Surveillance Network (지능형 클러스터 감시망 비상등관리시스템 개발)

  • Choi, Jae-Myeong;Kang, Heau-Jo
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.5
    • /
    • pp.906-912
    • /
    • 2011
  • In this paper, we structured the intelligent cluster surveillance network which can be managed scattered-the emergency light without communication line. Will not be interfered in location of emergency light and not to be will be able to establish the system. And the surveillance network there is by a destroyer and the communication relay system is born breakdown but the dead zone without condition of emergency light implemented the emergency light management system where the monitoring and management are possible. And we implemented the emergency light surveillance equipment and the emergency light monitoring system. Some experiments were conducted to verify so as to proposed system, and the system processes such as the surveillance network, the status information measurement and initialization were well performed.

A Study on the Transmission of Bio-Signal by TRS (TRS에 의한 생체신호의 전도에 대한 연구)

  • 곽준혁;최조천
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.05a
    • /
    • pp.366-372
    • /
    • 2002
  • Tele-medicine and emergency medical system are necessary for moving from an accidental point or far distance to a hospital and emergency treatment or home treatment before a hospital. Emergency treatment is extremely important in the case of death before arriving a hospital and deformed or disabled by medical treatment delay. A necessary element for this medical system is the emergency communication system. This system is on preparing for an ability of furnishing patient status to a corresponding health service by monitoring the patient at an ambulance of the accident place. This is the transportation of basic biological information of a patient to a medical center by wireless communication system and the corresponding hospital or medical center examine the patient by monitoring, then they can send emergency medical order to the patient for emergency treatment. The TRS is most efficient way of emergency medical communication system, which is currently used with popularity. In this paper studied simultaneously a way of detecting and transporting bio-logical signals, and monitoring of transporting data with communication of voice in the accident place or ambulance.

  • PDF

Application Study of Condition Monitoring Technology for Emergency Diesel Generator at Nuclear Power Plant (원자력발전소 비상디젤발전기 상태감시 기술 적용 연구)

  • Choi, K.H.;Park, J.H.;Park, J.E.;Lee, S.G.
    • Journal of Power System Engineering
    • /
    • v.13 no.1
    • /
    • pp.53-58
    • /
    • 2009
  • The emergency diesel generator(EDG) of the nuclear power plant is designed to supply the power to the nuclear reactor on Station Black Out(SBO) condition. The operation reliability of onsite emergency diesel generator should be ensured by a conditioning monitoring system designed to monitor and analysis the condition of diesel generator. For this purpose, we have developing the technologies of condition monitoring for the wolsong unit 3&4 standby diesel generator including diesel engine performance. In this paper, technologies of condition monitoring for the wolsong standby diesel generator are described about three step. First is for selection of operating parameter for monitoring. Second is for technologies of online condition monitoring, Third is for monitoring of engine performance.

  • PDF

Emergency Monitoring System Based on a Newly-Developed Fall Detection Algorithm

  • Yi, Yun Jae;Yu, Yun Seop
    • Journal of information and communication convergence engineering
    • /
    • v.11 no.3
    • /
    • pp.199-206
    • /
    • 2013
  • An emergency monitoring system for the elderly, which uses acceleration data measured with an accelerometer, angular velocity data measured with a gyroscope, and heart rate measured with an electrocardiogram, is proposed. The proposed fall detection algorithm uses multiple parameter combinations in which all parameters, calculated using tri-axial accelerations and bi-axial angular velocities, are above a certain threshold within a time period. Further, we propose an emergency detection algorithm that monitors the movements of the fallen elderly person, after a fall is detected. The results show that the proposed algorithms can distinguish various types of falls from activities of daily living with 100% sensitivity and 98.75% specificity. In addition, when falls are detected, the emergency detection rate is 100%. This suggests that the presented fall and emergency detection method provides an effective automatic fall detection and emergency alarm system. The proposed algorithms are simple enough to be implemented into an embedded system such as 8051-based microcontroller with 128 kbyte ROM.

Remote Monitoring of Patients and Emergency Notification System for U-Healthcare

  • Lee, Jun;Jang, Hyun-Se;Yang, Tae-Kyu;Seo, Yong-Ho
    • International journal of advanced smart convergence
    • /
    • v.2 no.1
    • /
    • pp.1-5
    • /
    • 2013
  • This study proposes a remote monitoring of patients and emergency notification system with a camera and pulse wave sensor for U-Healthcare. The proposed system is a server client model based U-Healthcare system which consists of wireless clients that have micro-controller, embedded-board for patient status monitoring and a remote management server. The remote management server observes the change of pulse wave data individually in real-time sent from the clients that is to be remote-monitored based on the pulse wave data stored by users and divides them into caution section and emergency section. When the pulse wave data of a user enters an emergency situation, the administrator can make a decision based on the real-time image information and pulse rate variability. When the status of the monitored patient enters the emergency section, the proposed U-healthcare system notifies the administrator and relevant institutions. An experiment was conducted to demonstrate the pulse wave recognition of the proposed system.

Development of an Integrated Control and Monitoring System for Emergency Power Generators (비상발전기 통합제어 및 감시시스템 개발)

  • 진강규;류길수;윤지근;유성호;김재환
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.192-196
    • /
    • 2001
  • These days, most of electric power facilities need high stability. Therefore integrated system has been required to monitor and control electronic power distribution system in fields at all times when the interruption of electric power has occurred. To construct this system, unit that convert and process the input signal from fields needed. And for control and monitoring from remote place MMI software is required. Lastly network equipments are required for real-time communications. So, in this paper, units for control and monitoring of emergency power generator and for electric power monitoring in normal electric power and interruption of electric power are developed. Also integrated remote system for monitoring in remote is developed.

  • PDF