• Title/Summary/Keyword: Emergency Monitoring

Search Result 471, Processing Time 0.03 seconds

Remote digital monitoring during the retention phase of orthodontic treatment: A prospective feasibility study

  • Sangalli, Linda;Savoldi, Fabio;Dalessandri, Domenico;Visconti, Luca;Massetti, Francesca;Bonetti, Stefano
    • The korean journal of orthodontics
    • /
    • v.52 no.2
    • /
    • pp.123-130
    • /
    • 2022
  • Objective: To evaluate if a remote digital monitoring system added at the end of orthodontic treatment could positively influence the retention phase by reducing the occurrence of misfit of removable appliances, number of emergency appointments (EA), and orthodontic relapse. Methods: Twenty-seven patients who completed active orthodontic treatment were divided into the study and control groups. In addition to the standard chairside follow-up appointments at month 1 (T1), month 3 (T2), month 6 (T3), the study group patients were monitored using Dental Monitoring® with monthly intra-oral scans. Occurrence of misfit of removable retainers, number of EAs, and intercanine width change were recorded for both groups. Differences in EAs and retainer fit were assessed using the chi-square test. Intra-group and inter-group differences in the intercanine width were assessed with Friedman test and Mann-Whitney U test, respectively (α = 0.05). Results: The study group showed a significantly lower occurrence of misfit of removable retainers (p = 0.027) compared to the control group. No significant inter- and intra-group difference was found in the EAs and intercanine width change at each time-point. Conclusions: Integrating remote monitoring systems, such as Dental Monitoring®, to the retention phase of the orthodontic treatment may lower the occurrence of misfit of removable retainers. However, a small sample size and a short observation period limit the strength of this evidence. These preliminary results tentatively suggest that remote monitoring technologies may be beneficial, especially during the COVID-19 pandemic, when the regularity of in-office visits might be disrupted.

Radiographic Status of the Visited Patients at University Hospital Emergency Room (한 대학병원 응급실 내원환자의 방사선촬영 실태)

  • Ahn, Byeoung-Ju
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.81-92
    • /
    • 2011
  • This study was carried out to improve service efficiency and to cope with a emergency situation in emergency radiography, through analysis of the radiographic distriution and literature cited about emergency care. Data collection of radiographic distribution was surveyed for 1270 emergency outpatients who visit during JAN, 2009at ER of the general hospital in Gwang city. The results is as follows : Emergency radiography rate of simple radiography was 56.6%, special radiography 2. 5%, CT 34.2%, and ultrasonography 6.7%, In simple radiography rate. a high rate was distributed on male(63.6%), thoracicsurgery part(90.0%), admission patient(77.9%), and long stayed patient at ER. In special raiography rate, a high rate was obsurved in urologic part(28.6%), and in CT rate, observed neurosurgerty part(49.2%) and neurologic part(36.7%). Ultrasonography rate was high for female(8.8%) and internal medicine part(15.9%). There are distributed regional radiography rate in radio-graphic type that chest(55.3%) is high in the simple radiography, urinary system(1.2%) in the special study, and brain(40.0%) in the CT. Regional radiography rate according to diagnostic department also was showed highly for head(64.6%) in neuro surgery, chest(90.0%) in thoracic surgery, abdomen(58.0%) in general surgery, spine(40.0%) in neuro surgery, and pelvis(15.9%), upper extrimity(20.5%), and lower extrimity(31.8%) in orthopedic surgery each. Mean radiographic case number per patient of simple radiography was sinificant on sex, age, transfer relation in both total and radiopraphic patients(p<0.05). Mean radiographic case number was highly distributed on male(2.2 case number) in sex, on thirties(2.7) in age, transferred patient(2.7) in patient type, and on nurosurgery(3.4) in diagnostic charged part. Total radiographic case number in regional party was highly distributed on chest(998 case number.) Considering the above results, emergency radiographer should take care of the elder patient in emergency radiography and get hold of injury mechanism to decrease possible secondary injury during radiography. Because of high radiography rate of urinary system in special study, related instrument. All radiographer who take charge emergency patient should cope with a emergency situation during radiography. Because head trauma patients is very important in patient care, especilly in CT at night, charged doctor should be always sitted with CT room and monitoring patient. Radiography was reqested by many diagnostic department in ER. Considering that rate of simple radiography is high, special room for emergency radiopraphy should be established in ER area, and the radioprapher of this room should be stationed radiologic technician who is career and can implement emergency patient care and The disposition of men which is appropriate with emergency patient increase is necessary.

The Establishment Plan of Strong-Motion Instrumentation of Dams for Monitoring of Seismic Behavior and Taking An Urgent Countermeasure (댐의 지진관측 및 내진대책 수립을 위한 지진계측시스템 구축 방안에 관한 연구)

  • Oh, Byung-Hyun;Lee, Jong-Wook
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.1588-1595
    • /
    • 2005
  • In this study, the installation location of accelerometer and accelerograph for dam are investigated in the field to establish of emergency action against dam failure when earthquake occur and to guarantee the results of seismic stability of dams which are analysed with dynamic analysis method during 1999 to 2003 by KOWACO. By a comparative study concerning of domestic and foreign guidelines of seismic strong motion instrumentation for dams, "Guidelines of Seismic Strong-Motion Instrumentation Installation, Operation and Maintenance for Dams" is established to set up the standard of seismic strong-motion instrumentation for dam, are supervised by KOWACO There is some problems in taking a measure of stability of dams when earthquake event occur because the existing seismic strong motion instruments are operated independently. This make difficult to confirm the occurrence of seismic event. For that reason, in this study the plan of unified operation and maintenance system for strong-motion instrument for dams is designed. It will make possible real-time seismic monitoring, data transmission and receiving, giving warning for earthquake, and exchanging data with national seismic network.

  • PDF

Function Analysis for the active surveillance system of urban transit (도시철도의 능동적 감시체계를 위한 기능 분석)

  • An, Tae-Ki;Shin, Jeong-Ryul;Lee, Woo-Dong;Han, Seok-Yoon;Kim, Moon-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1027-1028
    • /
    • 2008
  • Most of the urban transit operation company in Korea have a passive surveillance system to monitor the status of the passengers and facilities in the urban transit service area. The surveillance system is based on CCTV, closed circuit television, and several sensors, such as a fire sensor. However, this system has some limitations to prevent and cope with the emergency quickly. So the urban transit operation companies have plans to be change their surveillance system to be active. The active surveillance system has an intelligent function to detect the event predefined by managers automatically. To construct the active surveillance system, there are a standard concept design and a function analysis. In this paper, we propose the classification of the functions of the active surveillance system for urban transit. We divide the functions into five parts, ordinary monitoring, safety monitoring, environment monitoring, administration support, and record management. And we describe the systems related to the every functions to clarify the classified functions.

  • PDF

The Development of an Automatic Aquaculture System -1. Using a model tank- (양어장 자동화 시스템의 개발 -1. 모형 수조를 중심으로-)

  • KANG Ho-Won;LEE Seong-Ho;KIM Je-Yoon;JEONG Seok-Kwon;KIM Sang-Bong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.3
    • /
    • pp.294-300
    • /
    • 1995
  • In aquaculture industrial field, an automatic management and control system is needed to cope with the difficulties such as expensive wage, ripe age of management worker and risk according to the unexpected change of environmental conditions in the aquarium. This paper introduces an automatic aquarium monitoring and control system. The system is developed using PC single board computer. A PC can be connected to multi-single hoard computers, and the communication between PC and single board computers is based on RS-422/485 interfacing method. The physical data of pH, DO, temperature and water level etc. are real-timely treated in the single board computer though individual transducers, transfered to the main monitoring PC through RS-422/485 communication, and those data are graphically shown on the PC monitor. Furthermore, the environmental circumstance can be monitored through the image processing system, and the emergency system can be operated under the condition of environmental incident such as electric power stoppage, DO deficiency, pump shut down and low level water etc.

  • PDF

Design of Automatic Monitoring Network for the Water Quality Management of River Basin (하천 및 호소수 수질관리를 위한 자동측정망의 설계)

  • Choi, Ji-Yong;Park, Won-Kqyu;Lee, Sang-Il
    • Water for future
    • /
    • v.29 no.2
    • /
    • pp.167-178
    • /
    • 1996
  • In designing automatic water quality monitoring networks for a river basin, determination of measurement locations and items is critical to the effectiveness of the total system. In this paper we studied how to decide these two design factors when a monitoring network is designed for the purposse of water quality surveillance and emergency alarm. For measurement locations, candidate sites are chosen based on the intake amount for water supply and the point sources of contamination. Then, detailed locations are decided according to the contaminant flow distance. As for measurement items, characteristics and the accident history of water pollution in the basin must be taken into account. Considering economic aspects, we proposed a two-stage measurement plan: basic components for all locations and selective ones variable for different locations. Proposed methodology is demonstrated through a case study for Nak-dong River Basin.

  • PDF

Implementation of Infant Monitoring System using AHRS Algorithm (AHRS 알고리즘을 이용한 영유아 모니터링 시스템 개발)

  • Kim, Eun;Kim, Seokhoon;Kim, Dae-Young
    • Journal of Platform Technology
    • /
    • v.6 no.4
    • /
    • pp.41-48
    • /
    • 2018
  • Accidents involving infants and toddlers are occurring frequently, and if elementary measures are not smooth, they can lead to even greater accidents. Rapid elementary measures require an appropriate monitoring system, and it is necessary to build a system that can accurately monitor the child's living condition and notify the emergency situation immediately. Recently, with the development of IoT technology, various types of sensors are being developed in a very small size, and development of wearable devices connected with smart phones is accelerating with the development of smart phones. By using these wearable devices, it is possible to reduce the risk of infant accidents and to respond promptly in case of an accident. In this paper, we propose a wearable system that can monitor the infant condition and present a service to prevent infant accidents.

Development of Vehicle Longitudinal Controller Fault Detection Algorithm based on Driving Data for Autonomous Vehicle (자율주행 자동차를 위한 주행 데이터 기반 종방향 제어기 고장 감지 알고리즘 개발)

  • Yoon, Youngmin;Jeong, Yonghwan;Lee, Jongmin;Yi, Kyongsu
    • Journal of Auto-vehicle Safety Association
    • /
    • v.11 no.2
    • /
    • pp.11-16
    • /
    • 2019
  • This paper suggests an algorithm for detecting fault of longitudinal controller in autonomous vehicles. Guaranteeing safety in fault situation is essential because electronic devices in vehicle are dependent each other. Several methods like alarm to driver, ceding control to driver, and emergency stop are considered to cope with fault. This research investigates the fault monitoring process in fail-safe system, for controller which is responsible for accelerating and decelerating control in vehicle. Residual is computed using desired acceleration control command and actual acceleration, and detection of its abnormal increase leads to the decision that system has fault. Before computing residual for controller, health monitoring process of acceleration signal is performed using hardware and analytic redundancy. In fault monitoring process for controller, a process model which is fitted using driving data is considered to improve the performance. This algorithm is simulated via MATLAB tool to verify performance.

Development of Safety Monitoring Program for Psychiatric Emergency Using Google Teachable Machine (구글 티처블머신을 활용한 정신과적 응급 대상자의 병실 안전 모니터링 프로그램 개발)

  • Eun-Min Lee;Tae-Hun Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.1
    • /
    • pp.613-618
    • /
    • 2023
  • In this paper, a monitoring program that can automatically determine whether a patient admitted to an isolation room acts out of a stable state through a screen photographed in real time is described. The motion recognition model of this program was built by learning through transfer learning. 900 images were used for the three movements, and this program was developed for the web to support all environments. The model was determined with high accuracy to determine the state of the subject hospitalized in the isolation room, and can be applied by applying it to the existing isolation room monitoring system.

Estimation on Drought Indicator Using Various Time Series (다양한 시계열을 이용한 가뭄지표 산정)

  • Im, Gyeong-Jin;Sim, Myeong-Pil;Seong, Gi-Won;Lee, Hyeon-Jae
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.6
    • /
    • pp.673-685
    • /
    • 2001
  • In this study, the drought indicator is calculate from the rainfall, daily highest temperature, streamflow and Palmer Drought Severity Index(PDSI) for water plan and drought management in a relatively wide region. Three levels of drought severity, called drought watch, drought warning, and drought emergency, are established for these series which determine exceedance levels. The 25% nonexceedance level is used for drought watch, 10% for drought warning, and 5% for drought emergency to figure how well the drought indicators represent the past-drought and that those can be used for drought monitoring. As a result, 9-month and 12-month precipitation, and PDSI series shows the best consistency and high correlation indicate droughts. Because the results are based on the gauged data and simply calculated, the suggested indices can be used for basic data for drought monitoring system of a basin.

  • PDF