Development of Rule-based Checking Modules for the Evacuation Regulations of Super-tall Buildings in Open BIM Environments (개방형BIM환경에서의 룰기반 초고층건축물 피난법규 검토모듈 개발)

  • Kim, Inhan;Choi, Jungsik;Cho, Geunha
    • Korean Journal of Computational Design and Engineering
    • /
    • v.18 no.2
    • /
    • pp.83-92
    • /
    • 2013
  • IFC based open BIM has internationally developed as a solution for interoperability problem among different software applications. Despite much interest and effort, the open BIM technologies are rarely introduced to the construction industry and need more technical development for a practical application as well. This research aims to develop automated code checking modules for quality assurance process of BIM data. The research have analyzed domestic regulations focusing on super-tall buildings and developed open BIM-based code checking modules for the evacuation regulations. The modules are able to validate evacuation regulations such as installation of emergency elevator and fire safety zone. The authors expect to improve the process of BIM quality assurance and enhance the quality of BIM data by this research on automated checking system.

A Study on the Evacuation Performance Analysis Model Considering Clustering Types at the Fire Event in Geriatric Hospital (노인 요양병원에서 화재 시 군집유형에 따른 피난 성능 분석 모델에 관한 연구)

  • Kim, Mijung;Kweon, Jihoon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.28 no.1
    • /
    • pp.63-74
    • /
    • 2022
  • Purpose: The purpose of this study is to present an evacuation performance analysis model that can derive vulnerable evacuation spaces with considering the movement behavior as per the elderly groups in the event of a fire in a geriatric hospital. Methods: The evacuation characteristics of geriatric hospital users were investigated through the review of precedent studies. First, the occupant conditions and the evacuation scenario were set to analyze a study target hospital. Then, the evacuation simulation was carried out considering the group types and the density of each group. Finally, an evacuation performance analysis model according to the group type was presented based on the simulation results. Results: The results of this study are as follows: (1) The evacuation performance according to the group type is to be clarified through the suggested study model. (2) It is necessary to secure a ramp or an emergency elevator to distribute the evacuation personnel at the design stage because congestion occurs due to collisions between evacuees on the stairs and delays the evacuation time. (3) It is necessary to consider the evacuation stairs and openings of sufficient size by analyzing the frequency of congestion occurrence and the escape routes of occupants in advance to identify the space where the evacuation flow overlaps. Implications: It is expected that the study result is to be used as primary data for studies that consider the elderly and clustering evacuation behavior in the event of a fire in a geriatric hospital.

Smoke Control Performance of a Serial Structure Using "CONTAM" (CONTAM을 이용한 직렬형태 구조의 제연성능 구현에 관한 연구)

  • Kim, Mi-Seon;Seo, Dong-Gil;Gu, Seon-Hwan;Yoo, Young-Min;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.53-62
    • /
    • 2019
  • A recent trend shows that more buildings are being constructed as mixed-use (residential and commercial) properties for efficient land use. This has led to an increased frequency in the occurrence of fires and the associated potential risks. In particular, in case of high-rise apartments, at least one of the elevators in each building is installed for evacuation purposes separately from the emergency elevator; therefore, for a combined ancillary room and emergency elevator platform situation, the structure is inevitably in series with the evacuation elevator platform. Thus, a proposal for a new type of ventilation zone based on existing national fire safety codes is required to achieve smoke control performance. To this end, the air egress velocity and differential pressure of each ventilation zone are checked using the "CONTAM" software; further, an alternative is proposed to secure smoke control performance for series structures.

A study on the Comparison of High-rise building Egress Safety Rule in Countries for improvement of High-rise evacuation safety design criteria (초고층 피난안전설계 기준 개선을 위한 국내외 피난관계법령 비교에 관한 연구)

  • Hwang, EunKyung;Park, SuRoh
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.429-438
    • /
    • 2013
  • In this study, compare and analyze for high-rise evacuation safety design criteria improvement about internal high-rise building egress safety rule. To the result, high-rise evacuation safety design criteria improvement data can be summarized as follows. First, should compute the evacuation capacity about the number of persons and when more than 2 exits are requested, over 50% of evacuation capacity must be satisfied even approaching to 1 exit is unable. Second, 2 ways of evacuation can be made smoothly by the stair or exit separation-distance standard regulation. Third, regulate the length limitation of dead-end corridor or passageway and it should give grades in limitation of whether the spring-cooler has been installed. Fourth, must secure the evacuation way and do the evacuee guidance when it's safety area and elevator or stair. Also needs to provide extra safety area to secure horizontal direction Escape Safety except fire escaping floor.

A Study on Design Improvement for Smoke-Control System Using the Pressurization of the Elevator Shaft (승강로 가압 제연설비의 설계개선에 관한 연구)

  • Kim, Il-Young;Kim, Kyung-Jin;Hong, Ji-Hwan;Kwon, Chang-Hee;Yoo, Chul-Kwon
    • Fire Science and Engineering
    • /
    • v.33 no.3
    • /
    • pp.74-83
    • /
    • 2019
  • In the U.S., the pressurization of elevator shaft was developed in 1972 to allow vulnerable people, such as the elderly and weak who could not use escape stairs in case of fire, to evacuate. It is an advantage in terms of space saving by not using vertical ducts. This study drew the problem of the pressurization of elevator shaft based on the existing domestic patents and proposed improvements. The smoke control volume calculation method is proposed by using vertical modeling. Leakage gaps in elevator doors need to be reviewed through experimental data or actual data. The evacuation floor was divided, the openings in the elevator machine room were automatically closed to the fire signal and the relief damper was installed to improve the performance. The improved method functions as the smoke control damper supplying the air flow rather than maintaining the differential pressure. To increase reliability of the research results, the procedure was performed to verify by using Contam.

A Study on the Research Trends of Smoke Movement in Fire (화재 시 연기거동 관련 연구 동향에 관한 조사)

  • Kim, Hyung-Jin;Shin, Yi-Chul;Hwang, Eun-Kyung;Hwang, Keum-Suk;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.317-320
    • /
    • 2008
  • Smoke is recognized as the major killer in fire situation. smoke often migrate to building locations remote the fire space, threatening life and elevator shafts frequently become smoke-logged, there by blocking evacuation and inhibiting rescue and fire fighting. It is the aim of this study to investigate and analyze the research trends of smoke movement in Fire.

  • PDF

Basic Experimental Study on the Characteristics of Way Selection for the Development of Evacuation Simulation Model on board a Ship (선내 피난모델 개발을 위한 피난경로 선택특성에 관한 기초실험 연구)

  • Hwang, Kwang-Il;Sim, Young-Hoon
    • Journal of Navigation and Port Research
    • /
    • v.39 no.1
    • /
    • pp.29-35
    • /
    • 2015
  • As the numbers of users of domestic passenger ships increased up to 14.5 millions at 2012, the numbers of ships accidents also increased as 2 times than ever. It will be very important to develop technologies related with safety design for onboard passengers and disclose the potential problems. This study performed consciousness survey on ordinary peoples' way finding who have not got any regular anti-disaster training, to develop evacuation models for evacuation feasibility studies. Followings are the results answered by 83 participants for 33 way finding questions. Respondents selected right ways more than 6~18% for 2 ways like T type, U type, Y type passages. But when there are some walkers and/or runners, respondents preferred to select the way where walkers or runners are. And more over the ratio of the ways that runners are on is comparatively higher than walkers. On 'ㅏ'type, 'ㅓ'type and 3 way type passages, even though the walkers and/or runners are affected to answerers, straight way were most preferred. And it is clear that peoples like bright passages. On the other hands, peoples responded as they like right, downward and near stairs more than left, upward and far stairs, respectively. and very few selected escalator and elevator for as evacuation stairs.

A Study on the Research Trends of Evacuation Elevator in High-rise buildings (초고층건축물 피난엘리베이터관련 연구동향)

  • Seo, Dong-Goo;Lee, Jae-Won;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.484-487
    • /
    • 2012
  • 최근에는 피난안전측면에서 피난용 엘리베이터를 활용하기 위한 연구가 증대되고, 국가R&D사업이 추진되는 등 많은 관련연구가 진행되고 있다. 본 연구에서는 이러한 배경에 입각하여, 국내외의 연구동향을 살펴보고 국내의 법제화에 발맞추어 문제점 해결을 위한 연구필요성 도출을 목적으로 하였다. 연구동향 분석결과 국외의 경우 미국 NIST 및 일본건축학회 등 화재를 연구하는 기관을 중심으로 대응방안을 구축하고 있으며, 국내는 현재 거주자 피난행동과 연기제어 측면에서의 연구가 이루어지고 있었다. 하지만 엘리베이터 설비적인 측면에서의 기술향상도모는 미흡한 실정이다.

  • PDF