• Title/Summary/Keyword: Electrostatic loss

Search Result 57, Processing Time 0.024 seconds

Characteristics of Charging and Collection of 10-nm-Class Ultrafine Nanoparticles in an Electrostatic Precipitator (전기집진기의 10 nm 급 초미세 나노입자의 하전 및 집진 특성)

  • Han, Bang-Woo;Kim, Hak-Joon;Kim, Yong-Jin;Song, Dong-Keun;Hong, Won-Seok;Shin, Wan-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.10
    • /
    • pp.1013-1018
    • /
    • 2011
  • The charging of 10-nm-class nanoparticles in an electrostatic precipitator (ESP) according to particle charging ratio has been investigated and compared to the diffusion effect of the nanoparticles. The competition between the charging probability and the diffusion loss effect determines the collection efficiency of nanoparticles in the ESP. The collection efficiency of nanoparticles decreased continuously with decreasing particle diameter. This indicates that the partial charging effect of 10-nm-class nanoparticles is more dominant than their diffusion loss effect in the ESP for nanoparticles in the particle size range of less than 10 nm. The charging ratios based on unipolar diffusion charging calculations were in good agreement with the experimental collection efficiencies for nanoparticles less than 10 nm in diameter.

Development of Simple Bimodal Model for Charged Particle Coagulation (Bimodal 방법을 이용한 하전입자 응집 모델링)

  • Kim, Sang Bok;Song, Dong Keun;Hong, Won Seok;Shin, Wanho
    • Particle and aerosol research
    • /
    • v.10 no.1
    • /
    • pp.27-31
    • /
    • 2014
  • A simple bimodal model has been developed to analyze charged particle coagulation by modifying previously suggested bimdal model for evolution of particle generation and growth. In the present model, two monodisperse modes are used and 40 charge nodes are assigned to each mode to account both change of the particle size and charge distribution. In addition, we also implemented the effect of electrostatic dispersion loss in the present model. Based on the developed model, we analyzed coagulation of asymmetric bipolar charged particles by computing evolutions of particle number concentration, geometric mean diameter of particles, charge asymmetric ratio and geometric standard deviation of particle size distribution for various initial charge asymmetric ratios. The number concentration of asymmetric bipolar charged particles decreases faster than that of neutral particles but that does not give faster growth of particles since the electrostatic dispersion loss overwhelms particle growth by coagulation.

A Study on the Electrostatic Precipitation of Auto-Bias Type by Corona Discharge (코로나방전에 의한 AUTO-BIAS형태의 전기집진에 관한 연구)

  • 이주상;김신도;김광영
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.2
    • /
    • pp.79-88
    • /
    • 1995
  • The electrostatic precipitation of Auto- Bias has the advantages of a little of power consumption by the voltage to apply only at ionizer and the prevention of fire danger by current flow over. As this ionizer wire was used WXN- Pt material of diameter 90$\mu $m, that improved ion efficiency and safety, simplified a existing source of electric power by induced Auto- Bias voltage. Also, the new type collector used electric conductivity- film wag superior a electric safety and dust collection efficiency and was possible to wash it by water. As a experiment result of this Auto- Bias electrostatic collector, the induced Auto- Bias voltage by appling D.C 4.0∼6.0kV at ionizer was 1.3∼2.3kV and then the power consumption by applied voltage was 8- l8W. The pressure loss of collector by the amount of flowing was 6.1 OmmH$_{2}$O in 300m$^{3}$/hr and showed a safe state of the dust collection. The collection efficiency by particle size was 65.1-95.8% in 0.5∼5.0$\mu $m. After corona discharge of ionizer, the remains ozone concentration was found much lower than that of ACGIH or air pollution criteria in Korea.

  • PDF

Approach to Characterization of a Diode Type Corona Charger for Aerosol Size Measurement

  • Intra Panich;Tippayawong Nakorn
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.5
    • /
    • pp.196-203
    • /
    • 2005
  • A semi-empirical method to determine the electrostatic characteristics of a diode type corona aerosol charger based on ion current measurement and electrostatic charging theory was presented. Results from mathematical model were in agreement with those from experimental investigation of the charger. Current-voltage characteristics, $N_{i}t$ product and charge distribution against aerosol size were obtained. It was shown that the space charge was significant and must be taken into account at high ion number concentration and low flow rate. Additionally, significant particle loss was evident for particles smaller than 20 nm in diameter where their electrical mobility was high. Increase in charging efficiency may be achieved by introducing surrounding sheath flow and applying AC high voltage. Overall, the approach was found to be useful in characterizing the aerosol charger.

Penetration Efficiency of Charged Particles in a Cylindrical Tube Connection with Electrical Voltage Difference

  • Song, Dong-Keun;Kim, Tae-Oh
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.E1
    • /
    • pp.29-38
    • /
    • 2007
  • A cylindrical tube connection that has a voltage difference and is separated electrically by an insulator was modelled. The penetration efficiencies of charged particles passing through the connector tube were investigated. Typically, as the particle size decreases and the applied voltage difference increases, the penetration efficiency decreases. To assess the effect of the electrode geometry, various lengths of electric insulator and aerosol flow rate with a fixed tube length and tube diameter were used when calculating penetration efficiencies. The comparison of penetration efficiencies for various electrode geometry setups suggests that the penetration efficiency can be described as a function of the product of applied voltage and electrical mobility of charged particles. The diffusion loss from this and previous studies are compared. Further, an explicit form for penetration efficiency is provided as a function of a new non-dimensional parameter, $Es(=Z_pV/U_{avg}W);\;P_{es}=0.2{\cdot}{\exp}(-Es/0.6342)+0.8{\cdot}{\exp}(-Es/4.7914)$.

3D-QSAR Analysis on Antidepressant Activity of Tricyclic Isoxazole Analogues against Medetomidine-induced Loss of Righting (Medetomidine에 유발된 정좌반사소실에 대한 Tricyclic Isoxazole 유도체들의 항우울성에 관한 3D-QSAR 분석)

  • Choi, Min-Sung;Sung, Nack-Do;Myung, Pyung-Keun
    • YAKHAK HOEJI
    • /
    • v.55 no.2
    • /
    • pp.98-105
    • /
    • 2011
  • To search the minimum structural requirement of tricyclic isoxazole analogues (1~30) as new class potent antidepressant, thee-dimensional quanti- tative-structure relationship (3D-QSAR) models between substituents ($R_1{\sim}R_5$) of tricyclic isoxazoles and their antidepressant activity against medetomidine-induced loss of righting were performed and discussed quantitatively using comparative molecular field analysis (CoMFA) and comparative molecular similarity indies analysis (CoMSIA) methods. The correlativity and predictability ($r^2$=0.484 and $q^2$=0.947) of CoMSIA-2 model were higher than those of the rest models. The inhibitory activity against medetomidine-induced loss of righting was dependent on electrostatic field (43.4%), hydrophobic field (35.3%), and steric field (21.2%) of tricyclic isoxazoles. From the CoMSIA-2 contour maps, it is predicted that the antidepressant activity of potent antidepressants against medetomidine-induced loss of righting will be able to increase by the substituents ($R_1{\sim}R_5$) which were in accord with CoMSIA field.

Effects of Salts on Rheological Behaviour of Salvia Hydrogels

  • Yudianti, Rike;Karina, Myrtha;Sakamoto, Masahiro;Azuma, Jun-ichi
    • Macromolecular Research
    • /
    • v.17 no.5
    • /
    • pp.332-338
    • /
    • 2009
  • Rheological behavior of natural hydrogel produced from seeds of three Salvia spp. (S. miltiorrhiza (SM), S. sclarea (SS), S. viridis (SV)) was investigated by using a Rheometer equipped with a cone and plate geometry measuring system under never-dried condition. Different chemical contents of such hydrogels give significant effects on their rheological properties. Because of incomplete penetration of water inside the hydrogels after drying before-dried hydrogels were used for rheological analysis. To know molecular interactions which predominated in the gel formation, some constituents were externally added to the 1.0% (w/w) hydrogel. Addition of urea to disrupt hydrogen bonds reduced 3.4-67% viscosity of the untreated hydrogels and changed viscoelastic properties from gel to liquid-like behavior. Neutral salts added to the hydrogel solution at 0.1 M also lowered the viscosity in a manner related with increase in size of cations and temperature. Changing from gel state to liquid-like state was also easily confirmed by oscillation measurement (storage, G', and loss, G", modulii) typically observed in the cases of potassium sulfate and potassium thiocyanate. Influence of pH variation on the viscosity explained that weak alkaline condition (pH 8-9) creates a higher resistance to flow due to increasingly electrostatic repulsions between negative charges ($COO^-$) Importance of calcium bridges was also demonstrated by recovery of viscosity of the hydrogels by addition of calcium after acidification. The summarized results indicate that electrostatic repulsion is a major contributor for production of hydrogel structure.

Review on Effective Skills to Inhibit Dendrite Growth for Stable Lithium Metal Electrode (리튬금속전극의 덴드라이트 성장 억제 방안의 연구 동향)

  • Kim, Yerang;Park, Jihye;Hwang, Yujin;Jung, Cheolsoo
    • Journal of the Korean Electrochemical Society
    • /
    • v.25 no.2
    • /
    • pp.51-68
    • /
    • 2022
  • Although lithium metal batteries have a high energy density, experimental skills capable of solving lots of problems induced by dendrite such as short circuit, low coulomb efficiency, capacity loss, and cycle performance are still only in academic research stage. In this paper, research cases for dendrite growth inhibition on lithium metal electrode were classified into four types: flexible SEI (solid electrolyte interface) layer responding to volume expansion of lithium metal electrode, SEI supporting layer to inhibit dendrite growth physically, SHES (self-healing electrostatic shield) mechanism to adjust lithium growth by leading uniform diffusion of Li+ ions, and finally micro-patterning to induce uniform deposition of lithium. We hope to advance the practical use of lithium metal electrode by analyzing pros and cons of this classification.

Efficient Hybrid Carrier Based Space Vector Modulation for a Cascaded Multilevel Inverter

  • Govindaraju, C.;Baskaran, K.
    • Journal of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.277-284
    • /
    • 2010
  • This paper presents a novel hybrid carrier based space vector modulation for cascaded multilevel inverters. The proposed technique inherits the properties of carrier based space vector modulation and the fundamental frequency modulation strategy. The main characteristic of this modulation are the reduction of power loss, and improved harmonic performance. The carrier based space vector modulation algorithm is implemented with a TMS320F2407 digital signal processor. A Xilinx Complex Programmable Logic Device is used to develop the hybrid PWM control algorithm and it is integrated with a digital signal processor for hybrid carrier based space vector PWM generation. The inverter offers less weighted total harmonic distortion and it operates with equal electrostatic and electromagnetic stress among the power devices. The feasibility of the proposed technique is verified by spectral analysis, simulation, and experimental results.

FMEA of Electrostatic Precipitator for Preventive Maintenance (전기집진기 예지보전 단계에서의 고장모드영향분석)

  • Han, Seung-Hun;Lee, Jeong-Uk;Lee, Sun-Youp;Hwang, Jong-Deok;Kang, Dae-Kon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.6
    • /
    • pp.706-714
    • /
    • 2020
  • Currently, 90 % of the world's population breathes air with a fine dust content exceeding the World Health Organization's annual average exposure limit (10 ㎍/㎥). Global efforts have been devoted toward reducing secondary pollutants and ultra-fine dust through regulations on nitrogen oxides released over land and sea. Domestic efforts have also aimed at creating clean marine environments by reducing sulfur emissions, which are the primary cause of dust accumulation in ships, through developing and distributing environment-friendly ships. Among the technologies for reducing harmful emissions from diesel engines, electrostatic precipitator offer several advantages such as a low pressure loss, high dust collection efficiency, and NOx removal and maintenance. This study aims to increase the durability of a ship by improving equipment quality through failure mode effects analysis for the preventive maintenance of an electrostatic precipitator that was developed for reducing fine dust particles emitted from the 2,427 kW marine diesel engines in ships with a gross tonnage of 999 tons. With regard to risk priority, failure mode 241 (poor dust capture efficiency) was the highest, with an RPN of 180. It was necessary to determine the high-risk failure mode in the collecting electrode and manage it intensively. This was caused by clearance defects, owing to vibrations and consequent pin loosening. Given that pin loosening is mainly caused by vibrations generated in the hull or equipment, it is necessary to manage the position of pin loosening.