• Title/Summary/Keyword: Electron irradiation

Search Result 1,018, Processing Time 0.023 seconds

Shielding for Critical Organs and Radiation Exposure Dose Distribution in Patients with High Energy Radiotherapy (고 에너지 방사선치료에서 환자의 피폭선량 분포와 생식선의 차폐)

  • Chu, Sung-Sil;Suh, Chang-Ok;Kim, Gwi-Eon
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • High energy photon beams from medical linear accelerators produce large scattered radiation by various components of the treatment head, collimator and walls or objects in the treatment room including the patient. These scattered radiation do not provide therapeutic dose and are considered a hazard from the radiation safety perspective. Scattered dose of therapeutic high energy radiation beams are contributed significant unwanted dose to the patient. ICRP take the position that a dose of 500mGy may cause abortion at any stage of pregnancy and that radiation detriment to the fetus includes risk of mental retardation with a possible threshold in the dose response relationship around 100 mGy for the gestational period. The ICRP principle of as low as reasonably achievable (ALARA) was recommended for protection of occupation upon the linear no-threshold dose response hypothesis for cancer induction. We suggest this ALARA principle be applied to the fetus and testicle in therapeutic treatment. Radiation dose outside a photon treatment filed is mostly due to scattered photons. This scattered dose is a function of the distance from the beam edge, treatment geometry, primary photon energy, and depth in the patient. The need for effective shielding of the fetus and testicle is reinforced when young patients ate treated with external beam radiation therapy and then shielding designed to reduce the scattered photon dose to normal organs have to considered. Irradiation was performed in phantom using high energy photon beams produced by a Varian 2100C/D medical linear accelerator (Varian Oncology Systems, Palo Alto, CA) located at the Yonsei Cancer Center. The composite phantom used was comprised of a commercially available anthropomorphic Rando phantom (Phantom Laboratory Inc., Salem, YN) and a rectangular solid polystyrene phantom of dimensions $30cm{\times}30cm{\times}20cm$. the anthropomorphic Rando phantom represents an average man made from tissue equivalent materials that is transected into transverse 36 slices of 2.5cm thickness. Photon dose was measured using a Capintec PR-06C ionization chamber with Capintec 192 electrometer (Capintec Inc., Ramsey, NJ), TLD( VICTOREEN 5000. LiF) and film dosimetry V-Omat, Kodak). In case of fetus, the dosimeter was placed at a depth of loom in this phantom at 100cm source to axis distance and located centrally 15cm from the inferior edge of the $30cm{\times}30cm^2$ x-ray beam irradiating the Rando phantom chest wall. A acryl bridge of size $40cm{\times}40cm^2$ and a clear space of about 20 cm was fabricated and placed on top of the rectangular polystyrene phantom representing the abdomen of the patient. The leaf pot for testicle shielding was made as various shape, sizes, thickness and supporting stand. The scattered photon with and without shielding were measured at the representative position of the fetus and testicle. Measurement of radiation scattered dose outside fields and critical organs, like fetus position and testicle region, from chest or pelvic irradiation by large fie]d of high energy radiation beam was performed using an ionization chamber and film dosimetry. The scattered doses outside field were measured 5 - 10% of maximum doses in fields and exponentially decrease from field margins. The scattered photon dose received the fetus and testicle from thorax field irradiation was measured about 1 mGy/Gy of photon treatment dose. Shielding construction to reduce this scattered dose was investigated using lead sheet and blocks. Lead pot shield for testicle reduced the scatter dose under 10 mGy when photon beam of 60 Gy was irradiated in abdomen region. The scattered photon dose is reduced when the lead shield was used while the no significant reduction of scattered photon dose was observed and 2-3 mm lead sheets refuted the skin dose under 80% and almost electron contamination. The results indicate that it was possible to improve shielding to reduce scattered photon for fetus and testicle when a young patients were treated with a high energy photon beam.

Study on the Physical Properties of the Gamma Beam-Irradiated Teflon-FEP and PET Film (Teflon-FEP 와 PET Film 의 감마선 조사에 따른 물리적 특성에 관한 연구)

  • 김성훈;김영진;이명자;전하정;이병용
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.11-21
    • /
    • 1998
  • Circular metal electrodes were vacuum-deposited with chromium on the both sides of Teflon-FEP and PET film characteristic of electret and the physical properties of the two polymers were observed during an irradiation by gamma-ray from $\^$60/Co. With the onset of irradiation of output 25.0 cGy/min the induced current increased rapidly for 2 sec, reached a maximum, and subsequently decreased. A steady-state induced current was reached about in 60 second. The dielectric constant and conductivity of Teflon-FEP were changed from 2.15 to 18.0 and from l${\times}$l0$\^$-17/ to 1.57${\times}$10$\^$-13/ $\Omega$-$\^$-1/cm$\^$-1/, respectively. For PET the dielectric constant was changed from 3 to 18.3 and the conductivity from 10$\^$-17/ to 1.65${\times}$10$\^$-13/ $\Omega$-$\^$-1/cm$\^$-1/. The increase of the radiation-induced steady state current I$\^$c/, permittivity $\varepsilon$ and conductivity $\sigma$ with output(4.0 cGy/min, 8.5 cGy/min, 15.6 cGy/min, 19.3 cGy/min) was observed. A series of independent measurements were also performed to evaluate reproducibility and revealed less than 1% deviation in a day and 3% deviation in a long term. Charge and current showed the dependence on the interval between measurements, the smaller the interval was, the bigger the difference between initial reading and next reading was. At least in 20 minutes of next reading reached an initial value. It may indicate that the polymers were exhibiting an electret state for a while. These results can be explained by the internal polarization associated with the production of electron-hole pairs by secondary electrons, the change of conductivity and the equilibrium due to recombination etc. Heating to the sample made the reading value increase in a short time, it may be interpreted that the internal polarization was released due to heating and it contributed the number of charge carriers to increase when the samples was again irradiated. The linearity and reproducibility of the samples with the applied voltage and absorbed dose and a large amount of charge measured per unit volume compared with the other chambers give the feasibility of a radiation detector and make it possible to reduce the volume of a detector.

  • PDF

Detection Characteristics of Gamma-Irradiated Korean Medicinal Herbs by Using PSL, TL, and ESR (PSL, TL 및 ESR 분석에 의한 감마선 조사 한약재의 검지 특성)

  • Yang, Hee-Sun;Park, Yong-Dae;Jin, Chang-Hyun;Choi, Dae-Seong;Chung, Hyung-Wook;Byun, Myung-Woo;Jeong, Il-Yun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.11
    • /
    • pp.1529-1533
    • /
    • 2008
  • The detection characteristics of gamma-irradiated ($0{\sim}10.0\;kGy$) medicinal herbs (Platycodon grandiflorum, Acanthopanax chiisanensis) were investigated by photostimulated luminescence (PSL), thermoluminescence (TL), and electron spin resonance (ESR). The results of the PSL, a first screening method in comparison with the TL, showed photon counts greater than 5,000 counts/60 s (positive) in the irradiated samples, while the non-irradiated samples yielded photon counts less than 700 counts/60 s (negative). The TL was also applied for the detection method of irradiated medicinal herbs and showed that the non-irradiated sample revealed a glow curve with a low intensity, while the irradiated samples showed a higher intensity. These results were normalized by re-irradiating the mineral grains with a irradiation dose of 1.0 kGy, and a second glow curve was recorded. The ratio of the intensity of the first glow curve ($TL_1$) to that after the normalization dose ($TL_2$) was determined and compared with the recommended threshold values. TL ratio ($TL_1/TL_2$) was below 0.007 for the non-irradiated sample and higher than 0.1 for all irradiated samples (above 1.0 kGy). ESR spectroscopy revealed specific signals (6.065 mT) derived from free radicals in cellulose containing irradiated medicinal herbs. The P. grandiflorum showed clearer signals than A. chiisanensis. From the results of our studies, the PSL, TL, and ESR determinations were found to be suitable for the detection of irradiated medicinal herbs such as P. grandiflorum and A. chiisanensis.

Histomorphologic Change of Radiation Pneumonitis in Rat Lungs : Captopril Reduces Rat Lung Injury Induced by Irradiation (X-선 조사로 생긴 흰쥐 폐장 상해의 형태학적 변화: Captopril에 의한 폐장 상해의 경감 효과)

  • Kim, Jin-Hee
    • Radiation Oncology Journal
    • /
    • v.17 no.3
    • /
    • pp.238-248
    • /
    • 1999
  • Purpose : To assess the histomorphologic changes in the rat lung injury induced by radiation, to determine whether captopril reduces the rat lung injury and to evaluate change in TNF-${\alpha}$ and TGF-${\beta}$ in rat lung damage by radiation and captopril Methods and material : Right lungs in male Sprague-Dawley rats were divided irradiation alone (10, 20, 30 Gy) or radiation (same dose with radiation alone group) with captopril (500 mg/L). Radiation alone group were sacrificed at twelve hours and eleven weeks after radiation and radiation with captopril group (captopril group) were sacrificed at eleven weeks after radiation with captopril. We examined the light microscope and electron microscopic features in the groups. Results : In radiation alone group, there were patch parenchymal collapse and consolidation at twelve hours after radiation. The increase of radiation dose shows more prominent the severity and broader the affected areas. Eleven weeks after radiation, the severity and areas of fibrosis had increased in proportion to radiation dose given in the radiation alone group. There was notable decrease of lung fibrosis in captopril group than in radiation alone group. The number of mast cells rapidly increased with increase of radiation dose in radiation alone group and the degree of increase of mast cell number and severity of collagen accumulation more decreased in captopril group than in radiation alone group. In radiation alone group, expression of TNF-${\alpha}$ and TGF-${\beta}$ increased according to increase of radiation dose at twelve hours after radiation in both group. At eleven weeks after radiation, expression of TGF-${\beta}$ increased according to increase of radiation dose in radiation group but somewhat decreased in captopril group. In the captopril group the collagen deposition increased but less dense than those of radiation alone group. The severity of perivascular thickening, capillary change, the number and degranulation of mast cells more decreased in the captopril group than in the radiation alone group. Conclusion : It is concluded that the effect of captopril in the rat lungs after radiation was considered to be due to its effect on inhibition of mast cells and reduction of collagen deposition, and captopril may be protect in lung damage after radiation. We observed expression of TNF-${\alpha}$ and TGF-${\beta}$ increased at the early phase after radiation and expression of TGF-${\beta}$ increased in proportion to increase of radiation dose at the chronic phase after radiation. This results will contribute to future investigation in reduction mechanism of captopril in lung damage after radiation.

  • PDF

Mineralogical Studies of the Tourmaline for Medicinal Applications by Production Localities (본초 광물로서의 활용을 위한 산지별 전기석의 광물학적 연구)

  • Jie, Yan;Kim, Seon-ok;Park, Hee Yul;Park, Maeng-Eon
    • Economic and Environmental Geology
    • /
    • v.51 no.4
    • /
    • pp.345-358
    • /
    • 2018
  • In this study, we have performed electron probe micro analyzer (EPMA), X-ray differaction (XRD), inductively coupled plasma spectroscopy (ICP), Fourier transform Raman spectroscopy (FT-Raman), far-infrared (FIR), nuclear magnetic resonance (NMR), and pH-DO Analyses for characterizing medicinal mineralogy aspect of the black tourmaline (Shantung, china), black and pink tourmaline (Minas Geraris, Brazil), black touemaline (Daeyu mine, Korea). In addition, heating effects of the tourmaline sauna as well as the effects of tourmaline powder-added soap on skin troubles have been investigated. It has been revealed that chemical composition of the tourmaline is either high in Fe-, Al-, B-rich types. Ratio of the K-Ca, Na-K, and Fe-B reflects the component change property of solid solution. $CaO/CaO+Na_2O$ and MgO/FeO+MgO ratio show high positive correlation. When tourmaline reacts with distilled water, extended reaction time DO values approximately decrease and it stabilizes at DO = 10. Otherwise, pH values increase until 6 hours and it stabilizes at pH = 8 after 24 hours. Distilled water changes to alkaline when it reacts with tourmaline powder and particles. Tourmaline showed lower absorption spectrum strength and transmittance at short wave, where absorption spectrum wavelength and strength were determined by the content of the composition elements and characteristics of crystallography. Increase of the Fe content has been confirmed to be the cause for the reduction of irradiation. For the chemical composition and spectral property of the tourmaline particle samples, it has been found that Si and Fe contents show positive correlation with Far-Infrared irradiation, while Al and Mg contents show negative correlation. For tourmaline powder, it has been confirmed that $^{17}O-NMR$ FWHM (full width at half maximum) decreases when reacts with distilled water. Tourmaline sauna (approximately $100^{\circ}C$) was found to increase $0.5-1.5^{\circ}C$ of body temperature, average of 12 heartbeat, and 10mg Hg of blood pressure. Tourmaline soap had very good aesthetic effect to skin and was confirmed to have above the average improvements to skin troubles (e.g., allergy or atopy).

Conservative Surgery and Primary Radiotherapy for Early Bresst Cancer: Yonsei Cancer Center Experience (조기 유방암에서 보존적 수술후 방사선치료: 연세암센터 경험)

  • Suh Chang Ok;Lee Hy De;Lee Kyung Sik;Jung Woo Hee;Oh Ki Keun;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.12 no.3
    • /
    • pp.337-347
    • /
    • 1994
  • Breast conserving surgery and irradiation is now accepted as preferable treatment method for the patients with stage I and II breast cancer. Our institution activated team approach for breast conservation in 1991 and treated one hundred and fourty patients during the next three years. Purpose : To present our early experience with eligibility criteria, treatment techniques, and the morbidities of primary radiotherapy. Materials and Methods: Sixty four patients with early stage breast cancer who received breast conserving treatment between January 1991 and December 1992 were evaluated. All patients received partial mastectomy(wide excision to quadrantectomy) and axillary node dissection followed by radiotherapy. Total dose of 4500-5040 cGy in 5-5 1/2 weeks was given to entire involved breast and boost dose of 1000-2000 cGy in 1-2 weeks was given to the primary tumor site. Linac 4 MV X-ray was used for breast irradiation and electron beam was used for boost. Thirty five Patients received chemotherapy before or after radiotherapy. Patients characteristics, treatment techniques, and treatment related morbidities were analyzed. Results : Age distribution was ranged from 23 to 59 year old with median age of 40. Twenty-seven patients had T1 lesions and 34 patients had T2 lesions. In three patients, pathologic diagnosis was ductal carcinoma in situ. Thirty-seven Patients were N0 and 27 patients were Nl. There were three recurrences, one in the breast and two distant metastases during follow-up period(6-30 months, median 14 months). Only one breast recurrence occured at undetected separate lesion with microcalcifications on initial mammogram. There was no serious side reaction which interrupted treatment courses or severe late complication. Only one symptomatic radiation pneumonitis and one asymptomatic radiation pneumonitis were noted. Conclusions: Conservative surgery and primary radiotherapy for early breast cancer is Proven to be safe and comfortable treatment method without any major complication. Long-term follow up is needed to evaluate our treatment results in terms of loco-regional control rate, survival rate, and cosmetic effect.

  • PDF

EFFECT OF STEP CURING ON THE CONTRACTION STRESS AND MARGINAL ADAPTATION OF RESIN RESTORATION (단계별 광중합 방식이 복합레진 수복물의 수축 응력과 변연 접합도에 미치는 영향)

  • Park, Jong-Whi;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.2
    • /
    • pp.221-232
    • /
    • 2006
  • The purpose of this study was to investigate the effect of step-curing mode on polymerization shrinkage and contraction of composite resin restoration. Class I cavities were prepared on the extracted human premolars. The cavities were ailed with Filtek $Z-250^{TM}$ (hybrid resin, 3M ESPE, USA) and Filtek $flow^{TM}$ (flowable resin, 3M ESPE, USA) and cured with one of the following irradiation modes; Halogen 40sec with continuous curing, LED 10sec with continuous curing, and LED 13sec with step-curing. Contraction stress was measured with strain gauge which was connected to TML $Datalogger^{TM}$ (TDS-102, SOKKI, Japan) and resin-dentin interfaces were observed by scanning electron microscope. The results of present study can be summarized as follows : 1. Composite resin restoration showed transient expansion just after irradiation of curing light. Contraction stress was increased rapidly at the early phase of polymerization and reduced slowly as time elapsed (P<0.05) 2. $Filtek\;flow^{TM}$ showed lower contraction stress than Filtek $Z-250^{TM}$ regardless of curing modes. 3. LED step-curing mode showed lowest contraction stress in Filtek $Z-250^{TM}$ compared with other curing modes(P<0.05). 4. LED step-curing mode showed lowest contraction stress in $Filtek\;flow^{TM}$ compared with other curing modes(P<0.05), but difference in contraction stress was not so greate as in $Filtek\;Z-250^{TM}$. 5. Polymerization of composite resin by LED light with step-curing mode and halogen light with continuous ode resulted in better marginal sealing than LED light with continuous mode.

  • PDF

Studies on the Applications of PSL, TL and ESR Methods for the Detection of Dried Fruits and Mushrooms (PSL, TL 및 ESR 분석에 의한 건조과일류 및 버섯류에 대한 검지 특성 연구)

  • Kim, Kyu-Heon;Son, Jin-Hyok;Kang, Yoon-Jung;Park, Hye-Young;Hwang, Cho-Rong;Kim, Jae-I;Lee, Kang-Bong;Jo, Tae-Yong;Eom, Mi-Ok;Park, Sue-Nie;Seong, Rack Seon;Jang, Young-Mi;Lee, Jae-Hwang;Park, Yong-Chjun;Lee, Hwa-Jung;Lee, Sang-Jae;Han, Sang-Bae
    • Journal of Radiation Industry
    • /
    • v.7 no.1
    • /
    • pp.7-14
    • /
    • 2013
  • In this study, we investigated the applicability of the photostimulated luminescence (PSL), thermoluminescence (TL) and electron spin resonance (ESR) methods for various foods. The analysed samples consist of 11 items including dried fruits (6 items) and mushrooms (5 items). To compare between non-irradiated and irradiated food, all samples were irradiated with $^{60}Co$ gamma-ray source. In PSL study, the photon counts of all the unirradiated sample were identified negative (lower than 700). The photon counts irradiated (1, 5, 10 kGy) dried date-palm, dried jujube and mushrooms (Auricularia auricula, Phellinus linteus and Sarcodon aspratus) showed positive (higher than 5,000) and the results for the other samples were negative or intermediate (>700 and >5,000). In TL analysis most of items can be applicable to detect irradiated foods because of showing TL ratio above 0.1. The glow curves by TL method were estimated in the range of $150{\sim}250^{\circ}C$ in irradiated samples. In ESR measurements, the intensity of ESR signal (single-line) increased as the dose of irradiation increased. In particular, the specific ESR signals of irradiation-induced radical were detected in dried papaya, dried date-palm, dried banana, dried pineapple and S. aspratus. According to the results, PSL, TL and ESR methods were successfully applied to detect the irradiated foods. It is concluded that PSL, TL and ESR methods are suitable for detection of irradiated samples and a combined method is recommendable for enhancing the reliability of detection results.

Studies on the Applications of TL and ESR Methods for the Detection of Spices, Berry Fruits and Pollen Extract Product (TL과 ESR 분석을 통한 일부 향신료, 장과류 및 화분가공추출물 검지 특성 연구)

  • Kim, Kyu-Heon;Son, Jin-Hyok;Kang, Yoon-Jung;Park, Hye-Young;Kwak, Ji-Young;Lee, Jae-Hwang;Park, Yong-Chjun;Jo, Tae-Yong;Lee, Hwa-Jung;Lee, Sang-Jae;Han, Sang-Bae
    • Journal of Radiation Industry
    • /
    • v.7 no.1
    • /
    • pp.69-74
    • /
    • 2013
  • This study examined radiation detection characteristics of spices (cumin, caper and turmeric), other small fruits (hut-gae berry and boxthorn), and pollen extract product. Each samples were irradiated at dose of 1, 5, and 10 kGy and analyzed by the thermoluminescence (TL) and electron spin resonance (ESR) methods. To compare between non-irradiated and irradiated food, all samples were irradiated with $^{60}Co$ gamma-ray source. In TL analysis, most of samples could be applied to detect irradiated foods because of showing TL ratio above 0.1. The glow curves examined by TL method were estimated in the range of $150{\sim}250^{\circ}C$ in irradiated samples. In ESR measurements, the intensity of ESR signal (single-line) increased as the increase of irradiation dose. In particular, the specific ESR signals of irradiation-induced radical were detected in hut-gae berry and pollen extract product. As a results, it is considered that TL and ESR methods can be used to detect both hut-gae berry and pollen extract product. But cumin, caper, turmeric and boxthorn irradiated with gamma ray could be detected only by TL method. It is concluded that TL and ESR methods are suitable for detection of irradiated samples and a combined method is recommendable for enhancing the reliability of detection results.

Triptolide Mimics the Effect of Dietary Restriction on Lifespan and Retards Age-related Diseases in Caenorhabditis elegans (트립톨라이드가 식이제한에 의한 수명연장과 노화관련 질환에 미치는 영향)

  • Beak, Sun-Mi;Park, Sang-Kyu
    • Journal of Life Science
    • /
    • v.28 no.8
    • /
    • pp.931-937
    • /
    • 2018
  • Triptolide is a compound found in Tripterygium wilfordii and reported to have an anti-inflammatory and anti-oxidant activities. A previous study shows that the dietary supplementation with triptolide increases resistance to environmental stressors, including oxidative stress, heat shock, and ultraviolet irradiation, and extends lifespan in C. elegans. Here, we investigated the underlying mechanisms involved in the lifespan-extending effect of triptolide. The effect of triptolide on age-related diseases, such as diabetes mellitus and Alzheimer's disease, was also examined using animal disease models. The longevity phenotype conferred by triptolide was not observed in the eat-2 mutant, a well-known genetic model of dietary restriction, while there was an additional lifespan extension with triptolide in age-1 and clk-1 mutants. The long lifespan of age-1 mutant is resulted from a reduced insulin/IGF-1-like signaling and the clk-1 mutant lives longer than wild-type due to dysfunction of mitochondrial electron transport chain reaction. The effect of dietary restriction using bacterial dilution on lifespan also overlapped with that of triptolide. The toxicity of high glucose diet or transgenic human amyloid beta gene was significantly suppressed by the supplementation with triptolide. These findings suggest that triptolide can mimic the effect of dietary restriction on lifespan and onset of age-related diseases. We conclude that triptolide can be a strong candidate for the development of dietary restriction mimetics.