• 제목/요약/키워드: Electromagnetic vibration

검색결과 405건 처리시간 0.026초

MR유체를 이용한 다방향 제진형 마운트의 응답특성 (Response Property of Multi-directional Mount Using Magneto-Rheological Fluid)

  • 안영공;신동춘;양보석;이일영;김동조
    • 한국소음진동공학회논문집
    • /
    • 제13권7호
    • /
    • pp.517-523
    • /
    • 2003
  • This paper presents response property of the squeeze mode type mount using Magneto-Rheological fluid (MR fluid) . The MR mount for the isolation of multi-directional vibrations was constructed in this study. Both the mechanism and shape of the mount are the same as squeeze film dampers for a rotor system. In the present work, the performance of the mount was experimentally Investigated according to the magnetic field strength. The experimental results present that the MR mount can effectively reduce the vibration in a wide range of frequency by controlling the applied electromagnetic filed strength. Viscous damping and stiffness coefficients of the MR mount tend to be changed according to the variation of the applied currents In this study.

에어컨 홴 BLDC 전동기의 음향공진에 관한 연구 (Study on Acoustic Resonance of Air-conditioner Fan BLDC Motor)

  • 이홍주;권중학;이창민;황건용;황상문
    • 한국소음진동공학회논문집
    • /
    • 제19권9호
    • /
    • pp.863-869
    • /
    • 2009
  • Acoustic noises generated during motor operation in mechanical system are from electromagnetic, mechanical, aerodynamic and electrical sources. For identification of mechanical noise origins, misalignment, unbalance, fan shape, resonance, and vibration modes have been extensively considered to describe noise behavior. An experiment-based approach as well as a mathematical approach needs to be adopted for a realistic study into noise and vibration of the motor, because motor noise characteristics differ from type to type due to various noise sources. This paper analyzes noise characteristics of a brushless DC motor for air-conditioner fan, and proves that the test motor noise originates from acoustic modes of airspace in the motor. The motor noise sensitivity analysis by design of experiments reveals that the noise characteristics are closely related to switching frequency and frame thickness.

자기장 및 열하중을 받는 복합재료 판의 자유진동응답 (Free Vibration Responses of Composite Plates Subjected to Transverse Magnetic and Thermal Fields)

  • 김성균;최종운;김영준;박상윤;송오섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.136-142
    • /
    • 2011
  • The equations of motion for composite plates incorporating magneto-thermo-elastic effects have been derived via Hamilton's principle. In order to get the insight into the implications of a number of geometrical and physical features of the system, the vibrational responses of finite composite rectangular plates immersed in a transversal magnetic field are investigated by applying the extended Galerkin method. The vibration response characteristics of a composite plate are exploited in connection with the magnetic field intensity, thermal load, and electric conductivity of fibrous composite materials. Some pertinent conclusions, which highlight the various effects induced by the magneto-thermo-elastic couplings, are outlined.

  • PDF

MR유체를 이용한 스퀴즈모드형 마운트의 동특성 (Dynamic Properties of Squeeze Type Mount Using MR Fluid)

  • 하종용;안영공;양보석;정석권;김동조
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.374-378
    • /
    • 2003
  • This paper presents investigation of damping characteristics of squeeze mode type MR (Magneto-Rheological) mount experimentally. Since damping property of the MR fluid is changed by variation of the applied magnetic field strength, squeeze mode type MR mount proposed in the study has variable damping characteristics according to the applied magnetic field s strength. In the present work, the performance of the mount was experimentally investigated according to the magnetic field strength and exciting frequencies. The experimental results present that the MR mount can effectively reduce the vibration in a wide range of frequency by controlling the applied electromagnetic filed strength. Viscous damping and stiffness coefficients of the MR mount tend to be changed according to the variation of the applied currents in this study and MR effect is reduced by increasing exciting frequency.

  • PDF

진동신호 분석을 위한 On-Line 시스템 개발 (Developement of On-Line System for Vibration Signal Analysis)

  • 김언석;임성정;김영식;이영길;김재철;정찬수;정상진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.616-619
    • /
    • 1995
  • This paper describes developement of on-line system for vibration signal analysis. In the power system, the main reason of transformer fault is due to a large amount of current by a short-circuit and a ground-fault. The electromagnetic force caused by fault-current deforms transformer windings and results in vibration pattern change. Therefore if the continuous on-line vibration monitoring on transformer is performed, an incipient failure can be detected. The developed system is composed of data acquisition devices, user interface program, signal processing program, diagnosis and trend analysis program, self diagnosis program and communication program.

  • PDF

선형 펄스 모터의 진동 감소를 위한 전류 파형의 설계 (Design of Current Waves for the Vibration Decrease of Linear Pulse Motor)

  • 조윤현;서진호;이권순
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권4호
    • /
    • pp.174-180
    • /
    • 2005
  • Linear pulse motor (LPM) has the vibration during the operation because of magnetic characteristic which is caused by the mechanical configuration and the electromagnetic property. This paper proposes the calculation of thrust on the base of magnetic equivalent circuit for the purpose of the vibration minimization of LPM. The permeance of LPM is calculated and simulated from the construction tooth. The thrust is compared with the analytical method, the 3D finite element method (FEM) and the experimental values. The vibration of LPM is measured and estimated to select the input current wave for an optimal operation condition.

MR 유체를 이용한 스퀴즈모드형 마운트의 동특성 (Dynamic Properties of Squeeze Type Mount Using MR Fluid)

  • 안영공
    • 한국소음진동공학회논문집
    • /
    • 제13권6호
    • /
    • pp.490-495
    • /
    • 2003
  • This paper presents investigation of damping characteristics of squeeze mode type MR (magneto-rheological) mount experimentally. Since damping property of the MR fluid is changed by variation of the applied magnetic field strength, squeeze mode type MR mount proposed in the study has variable damping characteristics according to the applied magnetic field strength. In the present work, the performance of the mount was experimentally Investigated according to the magnetic field strength and exciting frequencies. The experimental results present that the MR mount can effectively reduce the vibration in a wide range of frequency by controlling the applied electromagnetic field strength. Viscous damping and stiffness coefficients of the MR mount tend to be changed according to the variation of the applied currents in this study and MR effect is reduced by increasing exciting frequency.

발전소 입형펌프 전동기의 전류/진동신호 특성 분석 (Analysis of Current/Vibration Characteristics for Vertical Pump Induction Motors in Power Plant)

  • 김연환;이두영;구재량;배용채;이현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.400-405
    • /
    • 2005
  • The diagnosis of mechanical load and of power transmission system failures is usually carried out through mechanical signals such as vibration signals, acoustic emissions, motor speed envelope. If the mechanical load comes from an electrical machine the mechanical failures could be detected previously. Mechanical rotor imbalances and rotor eccentricities are reflected in electric, electromagnetic and mechanical quantities. Therefore, many surveillance schemes apply to the Fourier spectrum of a line current in order to monitor the motor condition. Due to the interaction of the currents and voltages, both these current harmonics are also reflected by a single harmonic component in the frequency spectrum of the electric power. Motor Current Signature Analysis is the usuful technique to assess machine electrical condition.

  • PDF

Noise Lowering for a Large Variable Speed Range Use Permanent Magnet Motor by Frequence Shift and Structural Response Evaluation of Electromagnetic Forces

  • Arata, Masanori;Takahashi, Norio;Fujita, Masafumi;Mochizuki, Motoyasu;Araki, Takashi;Hanai, Takashi
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.67-74
    • /
    • 2012
  • According to electrical output up rating of a permanent magnet motor and request to operate for a large variable speed range, resonance between structural natural vibration and electromagnetic force inside the motor can take place and make noise. This paper describes the mechanism of a resonance between them and noise lowering procedure by frequency shift when they are applied to the reluctance torque largely employed new motor named Permanent magnet Reluctance Motor (PRM).

회전기계의 전자기 축전류에 대한 이론 및 실험 (Theory and Experiment for Electromagnetic Shaft Current in Rotation Machinery)

  • 김재실
    • 한국정밀공학회지
    • /
    • 제16권12호
    • /
    • pp.40-45
    • /
    • 1999
  • Electrical damages to critical parts in rotation machinery have caused may machinery failures and hours of costly downtime. The problem of shaft currents generated in non-electrical machines have puzzled both users and manufacturers of these machines. The main solution for preventing electro- magnetic type damage is to demagnetize all of the machinery parts, however this is costly and time consuming. Therefore a thorough investigation into the causes and physical characteristics of electro- magnetic shaft currents is needed. In this paper, the self excitation theory was developed for a simple model, and axial flux Faraday disk machine surrounded by a long solenoid. Experimental tests were conducted to investigate the physical characteristics on an electromagnetic self excitation rig. The theory showed that the directions of both the shaft rotation and the coil turns should e identical if self excitation is to occur. From the tests, the electromagnetic type shaft current had both AC and DC components occurred at all vibration frequencies. This could point to the way to detect small instabilities or natural frequency locations by monitoring shaft currents.

  • PDF