• 제목/요약/키워드: Electromagnetic Transients

검색결과 59건 처리시간 0.023초

New Modeling of Switching Devices Considering Power Loss in Electromagnetic Transients Program Simulation

  • Kim, Seung-Tak;Park, Jung-Wook;Baek, Seung-Mook
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.592-601
    • /
    • 2016
  • This paper presents the modeling of insulated-gate bipolar transistor (IGBT) in electromagnetic transients program (EMTP) simulation for the reliable calculation of switching and conduction losses. The conventional approach considering the physical property of switching devices requires many attribute parameters and large computation efforts. In contrast, the proposed method uses the curve fitting and interpolation techniques based on typical switching waveforms and a user-defined component with variable resistances to capture the dynamic characteristics of IGBTs. Therefore, the simulation time can be efficiently reduced without losing the accuracy while avoiding the extremely small time step, which is required in simulation by the conventional method. The EMTP based simulation includes turn-on and turn-off transients of IGBT, saturation state, forward voltage of free-wheeling diode, and reverse recovery characteristics, etc. The effectiveness of proposed modeling for the EMTP simulation is verified by the comparison with experimental results obtained from practical implementation in hardware.

과도현상 해석을 위한 시간 영역에서의 등가축약법 :프로니 해석기법을 이용한 등가 구동점 임피던스 모델의 구성 (Time domain Reduction Method for Electromagnetic Transients Study: Equivalent Driving-Point Impedance Model using Prony Analysis)

  • 홍준희;박종근
    • 대한전기학회논문지
    • /
    • 제43권4호
    • /
    • pp.687-690
    • /
    • 1994
  • This paper presents a method of obtaining transmission network equivalents from the network's response to the pulse excitation signal. Proposed method is base on Prony signal analysis and jtransfer function identification technique. As a result Thevenin-type of discrete-time filter model can be generated. It can reproduce the driving point impedance characteristic of the network.

  • PDF

자기압축회로의 EMTP 시뮬레이션 (Simulation of the Magnetic Pulse Compression Modulator using Electromagnetic Transients Program)

  • 최영욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2182-2183
    • /
    • 2005
  • A pulse generator of one stage magnetic pulse compression modulator was simulated by electromagnetic transients program (EMTP). The pulse generator was expected to generate ${\sim}80kV$ peak voltage, ${\sim}140ns$ pulse width and about $70{\sim}75%$ energy delivery efficiency from initial charge capacitor $(0.2{\mu}F)$ to dummy load $(25{\Omega})$. From this simulation, the scheme of pulse circuit could be estimated as a practically reasonable design.

  • PDF

전기설비 사고의 열적 특성 분석 (Analysis of Heat Characteristics for Fault Power Utility)

  • 김기화
    • 한국화재소방학회논문지
    • /
    • 제11권4호
    • /
    • pp.25-31
    • /
    • 1997
  • In this study, EMTP(Electromagnetic Transients Program) which is one of the most well-known computer simulation methods is used to collect the data for a power plant fault. EMTP is the program for an interpretation of the phenomena of electric transients, and is designed to manifest the data of the electric current and voltage etc. at the time of a power plant fault. By EMTP, I analyze the properties of the heat energy which are transferred from the electrics when a power plant fault brings out. In terms of the results of this study, it is able to measure the heat energy at a power plant fault (power transformer) and to be acquired of the related data. And moreover, these data are expected to be used as a standard for the protection of the fire owing to a high voltage power transformer fault.

  • PDF

전력유도 현상과 차폐계수 (Phenomenon of Power Interference and Screening Factor)

  • 황종선;김영민;이경욱;김재준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.621-624
    • /
    • 2001
  • A metal sheath provides a cable with electrostatic screening and a degree of magnetic screening. The presence of a screen on a cable also reduces the induction arising from the high-frequency components of transients caused by power-line switching and also induced transients from lightning strokes; such transient induced voltages are of increasing importance with the increasing use of miniaturized telecommunication equipment with very small thermal capacity. This paper describes electrostatic induction and electromagnetic induction caused by power interference. Also screening factors are proposed.

  • PDF

Improved Circuit Model for Simulating IGBT Switching Transients in VSCs

  • Haleem, Naushath Mohamed;Rajapakse, Athula D.;Gole, Aniruddha M.
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1901-1911
    • /
    • 2018
  • This study presents a circuit model for simulating the switching transients of insulated-gate bipolar transistors (IGBTs) with inductive load switching. The modeling approach used in this study considers the behavior of IGBTs and freewheeling diodes during the transient process and ignores the complex semiconductor physics-based relationships and parameters. The proposed circuit model can accurately simulate the switching behavior due to the detailed consideration of device-circuit interactions and the nonlinear nature of model parameters, such as internal capacitances. The developed model is incorporated in an IGBT loss calculation module of an electromagnetic transient simulation program to enable the estimation of switching losses in voltage source converters embedded in large power systems.

전자기 과도 현상 해석을 위한 등가 시스템 (Equivalent System for Electromagnetic Transients Study)

  • 박종근;홍준희;박동욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.843-847
    • /
    • 1988
  • In electromagnetic transient analysis studies, complex transmission system should be modelled in detail. But in large system, modelling of complete system is a big burden in many sides such as computation time, modelling efforts. It is needed to model only a concerned part of the system in detail. The remaining parts of the system have to be reduced to equivalents. This study suggests a method of generating a simple network equivalents which has equivalent frequency charastics in wide frequency range.

  • PDF

Electromagnetic Field Analysis on Surge Response of 500 kV EHV Single Circuit Transmission Tower in Lightning Protection System using Neural Networks

  • Jaipradidtham, Chamni
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1637-1640
    • /
    • 2005
  • This paper presents a technique for electromagnetic field analysis on surge response due to Mid-span back-flashovers effects in lightning protection system of 500 kV EHV single circuit transmission tower by the neural networks method. These analyses are based on modeling lightning return stroke as well as on coupling the electromagnetic fields of the stroke channel to the line. The ground conductivity influences both the electric field as well as the coupling mechanism and hence the magnitude and wave shape of the induced voltage. The technique can be used to analyzed the corona voltage effect, the effective of stroke to the span tower, the surge impedance of transmission lines. The maximum voltage from flashovers effects in the lines. The model is compatible with general electromagnetic transients programs such as the ATP-EMTP. The simulation results show that this study analyses for time-domain with those produced by a cascade multi-section model, the surge impedance of a full-sized tower hit directly by a lightning stroke is discussed.

  • PDF

배전시스템에서의 파라미터에 따른 과도현상 분석 (Transients Analysis for Parameters on Electrical Distribution System)

  • 김재철;오정환;임성정
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권3호
    • /
    • pp.88-96
    • /
    • 1997
  • 본 논문은 배전시스템에서의 파라미터에 따른 과도현상을 분석하였다. 재투입에 의한 순간전압강하와 개폐서지를 분석하였으며, 이를 위해서 22.9[kV] 배전시스템의 실 데이터를 이용하여 다중접지된 모델 시스템을 구성하였다. EMTP 시뮬레이션을 통하여 주상변압기 2차측 수용가에서의 재투입 영향을 분석하였으며, 사고선로와 인근선로에서의 과도현상을 나타냈었다. 또한 사고위치, 부하크기, 부하역률, 캐패시터뱅크의 크기, 재투입 위상각에 대한 파라미터 분석을 하였고, 이들 요소와 재투입에 의한 과도 현상과의 관계를 나타내었다.

  • PDF

전력유도 현상과 차폐계수 (Phenomenon of Power Interference and Screening Factor)

  • 황종선;김영민;이경욱;김재준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.621-624
    • /
    • 2001
  • A metal sheath provides a cable with electrostatic screening and a degree of magnetic screening. The presence of a screen on a cable also reduces the induction arising from the high-frequency components of transients caused by power-line switching and also induced transients from lightning strokes; such transient induced voltages are of increasing importance with the increasing use of miniaturized telecommunication equipment with very small thermal capacity. This paper describes electrostatic induction and electromagnetic induction caused by power interference. Also screening factors are proposed.

  • PDF