• Title/Summary/Keyword: Electrode Tip

Search Result 171, Processing Time 0.026 seconds

Evaluation of the Induction and Ionized Field Charging Methods for Electrostatic Nozzles of Orchard Sprayer

  • Laryea, G.N.;No, S.Y.;Lee, D.H.
    • Agricultural and Biosystems Engineering
    • /
    • v.3 no.1
    • /
    • pp.29-34
    • /
    • 2002
  • Two charging methods of electrostatic nozzle, i.e. induction and ionized field corona charging, were designed and evaluated for orchard sprayer application. An artificial (metallic) target was constructed and used in this experiment. The charge-to-mass ratio for the induction electrode was measured by using the Faraday cage. Two conventional pressure-swirl nozzles have been employed with different orifice diameters under the same experimental operating conditions. A commercial pressure-swirl nozzle with orifice diameter of 1.0 was used for the conventional spray. The diameter of the electrostatic was 0.59 mm. The experiment was carried out for individual nozzle sprays at $0^{\circ}$, $20^{\circ}$ and $50^{\circ}$ oriented angles and three nozzles, sprayed simultaneously at a distance of 1.0 and 2.0 m from the nozzle tip to the target. The nozzles were mounted on a carriage with constant speed of 1.26 km/h with a blower attached. The weighing method was employed to evaluate for the spray deposition, ground loss and estimated drift. The results show more promising for the induction charging method, especially at $20^{\circ}$oriented angle at a distance of 1.0 m from the target for a single nozzle and when all three nozzles were operated simultaneously for spray deposition. The results of the induction charging method show promising with the developed electrostatic technique.

  • PDF

Analysis of Piezoelectric Ceramic Multi-layer Actuators Based on the Electro-mechanical Coupled Meshless Method (전기-기계 결합 하중을 받는 압전 세라믹 다층 작동기의 무요소 해석)

  • Kim, Hyun-Chul;Guo, Xianghua;Kim, Won-Seok;Fang, Daining;Lee, Jung-Ju
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.2
    • /
    • pp.101-108
    • /
    • 2007
  • This paper presents an efficient meshless method for analyzing cracked piezoelectric structures subjected to mechanical and electrical loading. The method employs an element free Galerkin (EFG) formulation and an enriched basic function as well as special shape functions that contain discontinuous derivatives. Based on the moving least squares (MLS) interpolation approach, The EFG method is one of the promising methods for dealing with problems involving progressive crack growth. Since the method is meshless and no element connectivity data are needed, the burdensome remeshing procedure required in the conventional finite element method (FEM) is avoided. The numerical results show that the proposed method yields an accurate near-tip stress field in an infinite piezoelectric plate containing an interior hole. Another example is to study a ceramic multilayer actuator. The proposed model was found to be accurate in the simulation of stress and electric field concentrations due to the abrupt end of an internal electrode.

A compact and low-power consumable device for continuous monitoring of biosignal (소형화 및 저전력소모를 구현한 실시간 생체신호 측정기 개발)

  • Cho, Jung-Hyun;Yoon, Gil-Won
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.334-340
    • /
    • 2006
  • A compact biosignal monitoring device was developed. Electrodes for electrocardiogram (ECG) and a LED and silicon detector for photoplethysmogram (PPG) were used. A lead II type was arranged for ECG measurement and reflected light was measured at the finger tip for PPG. A single chip microprocessor (model ADuC812, Analog Device) controlled a measurement protocol and processed measured signals. PPG and ECG had a sampling rate of 300 Hz with 8-bit resolution. The maximum power consumption was 100 mW. The microprocessor computed pulse transit time (PTT) between the R-wave of ECG and the peak of PPG. To increase the resolution of PTT, analog peak detectors obtained the peaks of ECG and PPG whose interval was calculated using an internal clock cycle of 921.6 kHz. The device was designed to be operated by 3-volt battery. Biosignals can be measured for $2{\sim}3$ days continuously without the external interruptions and data is stored to an on-board memory. Our system was successfully tested with human subjects.

Preventing Method against the Occurrence of a Corona between a Dead End clamp and a Porcelain Insulator Used in 154kV Substation

  • Han, Woon-Ki;Choi, Jong-Soo;Lee, Jun;Kim, Jae-Chul
    • International Journal of Safety
    • /
    • v.6 no.2
    • /
    • pp.22-26
    • /
    • 2007
  • An episode of corona is a heterogeneity-caused electric discharge that occurs when electric fields are formed layer on layer and concentrated on an electrode. Electric wires built at the tip of 154kV private facilities use dead end clamp spawns corona from homogeneity caused by field concentration. Corona induces power loss, noise, insulator failure and more. In this research, we've studied the characteristics of coronas that take place in porcelain insulators and terminal electric wires of supporting hard wares (dead end clamp) that are set up as spares in the 154kV private facilities use hydroelectricity installations to support electric wires. Corona, which cannot be identified by regular methods, was measured utilizing UV image camera. As the result of measuring corona via UV image camera, we've confirmed that the depletion of insulators was accelerated following the wire end treatment method and validated the stress intensity of insulators at various lengths of bare wires caused by electric fields via FEMLAB. We have also proposed a new model for relieving homogeneity-caused field concentration, and after analyzing the proposed model via FEMLAB, we've confirmed that the concentration of field distribution was indeed reduced. Such results are exploited in installation of private facilities use equipments, maintenance of insulators and hard wares as well as safety enhancement, and are anticipated to be effectively utilized in corona prevention measures.

Electrical Treeing Deterioration and Dielectric Breakdown Phenomena in Polymeric Insulator (고분자 절연재료에서 전기트리 열화 및 절연파괴 현상)

  • Cho, Yeong-Sin;Kim, Sang-Uk
    • Korean Journal of Materials Research
    • /
    • v.9 no.4
    • /
    • pp.398-403
    • /
    • 1999
  • Studies on the electrical treeing deterioration and dielectric breakdown phenomena in the polymeric insulator of polyethylene and epoxy resin were carried out. Block type samples with needle-plane electrode geometry were electrically stressed and the tree pattern from the needle tip was observed. In LDPE the density of electrical tree was very high and its pattern was bush type. For the case of XLPE, branched tree was observed. As temperature and SN content increased, the dielectric breakdown voltage decreased and the treeing phenomena became more complicated. Fan type cracks were observed around the conducting tree path in the brittle DGEBA/MDA system.

  • PDF

Development and Strength Evaluation of Ring Projection Welding Process of the Microminiature Tube and Tubesheet (초소형 튜브와 튜브판의 링 프로젝션 용접 공정개발 및 강도 평가)

  • Yun, Young-Hyun;Kim, Hyun-Joon;Kim, Chang-Soo;Cho, Sang-Myung
    • Journal of Welding and Joining
    • /
    • v.27 no.2
    • /
    • pp.63-68
    • /
    • 2009
  • Microminiature heat exchanger has been applied to the gas turbine in order to increase energy efficiency. During the production of microminiature heat exchanger, however, it is very difficult to weld tube to tubesheet. In this study, therefore, welding process of resistance ring projection was used, and weld tensile tests were performed. Sound weld joint was obtained as a result of applying resistance ring projection welding to microminiature heat exchanger to tubesheet. Cold weld occurred at under 1600A. Even though tensile strength was increased with increasing current, splash occurred and tensile strength decreased at 2000A due to the excessive current. Therefore it was determine that the optimal current is 1900A. As result of tensile tests based on ASME code for tube to tubesheet weldment, rupture position was weldment due to Fs(Fractured section) of nugget, which was smaller than tube thickness (t), and it was proven as a partial strength welding because of the average joint efficiency fr = 0.90.

The Effects of Welding Parameters on Quality in Lap Joint Fillet Welds of Thin Plate by Plasma Welding (Plasma 용접에 의한 박판 겹치기 이음 필릿 용접부의 품질에 미치는 용접 변수의 영향)

  • Park, Kun-Gi;Yang, Jong-Soo;Cho, Sang-Myung;Yoon, Hun-Sung
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2006.09a
    • /
    • pp.122-127
    • /
    • 2006
  • In case of lap joint fillet welds of thin plate, the example which is applicable to Plasma Welding increases substituting for the exiting TIG Welding but the quality of Plasma arc welding has a special feature influenced sensitively by the condition of welding caused by controlling the various parts of welding torch. This research is purposed to improve lap joint fillet welds of thin plate in high quality and attain the high productivity and it is examined that how the change of electrode tip angle and Setback has an effect on the quality of welding and it is investigated how the change of Setback and Standoff has an effect on Melting efficiency using Response Surface Analysis.

  • PDF

Hydrodynamic Modeling for Discharge Analysis in a Dielectric Medium with the Finite Element Method under Lightning Impulse

  • Lee, Ho-Young;Lee, Se-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.3
    • /
    • pp.397-401
    • /
    • 2011
  • The response of lightning impulse voltage was explored in dielectric liquids employing hydrodynamic modeling with three charge carriers using the finite element method. To understand the physical behavior of discharge phenomena in dielectric liquids, the response of step voltage has been extensively studied recently using numerical techniques. That of lightning impulse voltage, however, has rarely been investigated in technical literature. Therefore, in this paper, we tested impulse response with a tip-sphere electrode which is explained in IEC standard #60897 in detail. Electric field-dependent molecular ionization is a common term for the breakdown process, so two ionization factors were tested and compared for selecting a suitable coefficient with the lightning impulse voltage. To stabilize our numerical setup, the artificial diffusion technique was adopted, and finer mesh segmentation was generated along with the axial axis. We found that the velocity from the numerical result agrees with that from the experimental result on lightning impulse breakdown testing in the literature.

Development of Laser-Rotating An Hybrid Welding Process (레이저-회전 아크 하이브리드 용접공정의 개발)

  • Kim, Cheol-Hee;Chae, Hyun-Byung;Lee, Chang-Woo;Kim, Jeong-Han;Rhee, Se-Hun
    • Journal of Welding and Joining
    • /
    • v.24 no.1
    • /
    • pp.88-92
    • /
    • 2006
  • Laser-rotating arc hybrid welding was introduced by combining $CO_2$ laser and rotating gas metal arc welding. While the arc rotation enhances the weld pool motion, it reduces the undercut formation which is one of most critical weld defects in the conventional laser-arc hybrid welding. This research investigated the bead characteristics according to the welding parameters such as frequency of rotation, welding voltage, shielding gas composition and interspacing distance between laser and we. The welding parameters were selected to reduce spatter generation and ensure sound weld beads fur bead welding and butt welding with various joint gaps. Gap bridging ability was improved, such that the sound weld beads were achieved for butt joint with up to 2mm joint sap, with no adjustment of CTWD(Contact tip-to-workpiece distance) and electrode diameter.

Repassivation Behavior of Ni Base Alloys in a Mild Alkaline Water at 300℃

  • Hwang, Seong Sik;Kim, Dong Jin;Kim, Joung Soo;Kim, Hong Pyo
    • Corrosion Science and Technology
    • /
    • v.5 no.3
    • /
    • pp.85-89
    • /
    • 2006
  • KAERI(Korea Atomic Energy Research Institute) has developed a repassivation rate test system which can be operated at $300^{\circ}C$. It consists of an autoclave, three electrodes for an electrochemical test and a diamond scratch tip. All the electrodes are electrically insulated from the autoclave by using high temperature fittings. Reproducible repassivation curves of alloy 600 at 300 C were obtained. Repassivation rate of alloy 600 at pH 13 was slower than that of pH 10. Stress corrosion cracking test was carried as a function of the pH at a high temperature. At pH 10, alloy 600 showed a severe stress corrosion cracking(SCC), whereas it did not show a SCC at pH 7. From the viewpoint of a relationship between the current density and the charge density, a big difference was observed in the two solutions; the slope of pH 13 was steeper than that of pH 10. So the stress corrosion susceptibility at pH 13 seems to be higher than that of pH 10. The system would be a good tool to evaluate the SCC susceptibility of alloy 600 at a high temperature.