• Title/Summary/Keyword: Electrode Tip

Search Result 171, Processing Time 0.024 seconds

A Non-contact Detection Method for Smelting in Submerged Arc Furnace based on Magnetic Field Radiation

  • Liu, WeiLing;Chang, XiaoMing
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.204-208
    • /
    • 2016
  • This paper demonstrates the key parameter detection for smelting of submerged arc furnace (SAF) based on magnetic field radiation. A magnetic field radiation model for the inner structure of SAF is established based on relative theory of electromagnetic field. A simple equipment of 3D magnetic field detection system is developed by theoretical derivation and simulation. The experiments are carried out under the environment of industrial field and AC magnetic field generated by electrode currents and molten currents in the furnace is reflected outside of the furnace. The experimental results show that the key parameters of smelting including the position of electrode tip, the length of electric arc, and the liquid level of molten bath can be achieved. The computed tomography for SAF can be realized by the detection for smelting.

Effects of Curing Agent Content and Post-curing Conditions on Dielectric Deterioration Characteristics of DGEBA/MDA/SN System (경화제 함량과 후기경화조건에 따른 DGEBA/MDA/SN계의 절연열화 특성)

  • 조영신;박수길;임기조;심미자;김상욱
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.313-316
    • /
    • 1997
  • The effects of aromatic curing agent of MDA contents and post curing conditions on dielectric deterioration characteristics of DGEBA/MDA/SN system were investigated. The dielectric properties were measured by using needle-plane electrode geometry under the commercial AC high electric field application. As the curing agent content increased, the dielectric breakdown strength increased and then decreased slightly. All the trees initiated from the tip of needle electrode and the shape of the tree in this system was a dendrite type.

  • PDF

생물공정 모니터링을 위한 Fiber Optic 생물센서 개발

  • Son, Ok-Jae;Lee, Jong-Il
    • 한국생물공학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.819-822
    • /
    • 2001
  • In this study a fiber optic biosensor has been developed to on-line monitor the concentrations of oxygen and glucose. The oxygen concentrations in solution and gas phase monitored by the fiber optic sensor has been compared with those by a dissolved oxygen electrode and an IR-type $O_2$ analyzer. The fiber optic glucose sensor has been made by immobilizing glucose oxidase on the tip of the optic fiber and used to on-line monitor the concentration of glucose in a fermentation process.

  • PDF

A study on the weldability of galvannealed steel in spot welding process (Galvannealed Steel의 点溶接의 溶接性에 관한 硏究)

  • 류병길;강춘식
    • Journal of Welding and Joining
    • /
    • v.5 no.1
    • /
    • pp.64-72
    • /
    • 1987
  • The Weldability of gavannealed steel using spot welder has been studied. The Results obtained are a follows; 1) Welds size and strength were increased depending on the welding time and welding current. But, the increasing rate has been decreased. 2) Deposited zinc has affected on the wear of welding tips and growth of welds but has not affected the weld's structures. 3) On shear testing of the specimen, button fracture has been observed and the value was approximately 540Kg (welds dia. approximately .phi.4mm)

  • PDF

Effects of Volatile Impurities on Dielectric Breakdown Characteristics of XLPE (XLPE의 절연파괴특성에 미치는 휘발성 불순물의 영향)

  • 조영신;심미자;김상욱
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.301-304
    • /
    • 1997
  • Effects of volatile impurities on deterioration characteristics of XLPE were investigated. Block type plate with needle-plane electrode and artificial void filled with $N_2$gas or humidity was subjected under high electric field. The dyed region by oxidation reaction around the artificial void filled with humidity was detected before tee initiation. Electrical tree was started from the tip of void filled with $N_2$gas earlier than humidity.

  • PDF

Interfacial Breakdown characteristics in XLPE/EPDM Laminate (XLPE/EPDM laminate의 절연파괴특성)

  • 남진호;서광석
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.495-497
    • /
    • 1999
  • In order to determine what influences the interfacial breakdown in EPDM/XLPE laminates, We made the breakdown test ceil and this was pressure controllable breakdown test cell. We make the needle electrode (tip radius: about 10 micrometer) using electrochemical method. We studied the interfacial silicone oil was higher than that with silicone grease. As a function of heat treatment time in a vacuum, interfacial breakdown strength increased much in XLPE/EPDM laminates pasted with silicone grease but increased a little in that with silicone oil.

  • PDF

Applications of Scanning Electrochemical Microscopy (SECM) Coupled to Atomic Force Microscopy with Sub-Micrometer Spatial Resolution to the Development and Discovery of Electrocatalysts

  • Park, Hyun S.;Jang, Jong Hyun
    • Journal of Electrochemical Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.316-326
    • /
    • 2016
  • Development and discovery of efficient, cost-effective, and robust electrocatalysts are imperative for practical and widespread implementation of water electrolysis and fuel cell techniques in the anticipated hydrogen economy. The electrochemical reactions involved in water electrolysis, i.e., hydrogen and oxygen evolution reactions, are complex inner-sphere reactions with slow multi-electron transfer kinetics. To develop active electrocatalysts for water electrolysis, the physicochemical properties of the electrode surfaces in electrolyte solutions should be investigated and understood in detail. When electrocatalysis is conducted using nanoparticles with large surface areas and active surface states, analytical techniques with sub-nanometer resolution are required, along with material development. Scanning electrochemical microscopy (SECM) is an electrochemical technique for studying the surface reactions and properties of various types of electrodes using a very small tip electrode. Recently, the morphological and chemical characteristics of single nanoparticles and bio-enzymes for catalytic reactions were studied with nanometer resolution by combining SECM with atomic force microscopy (AFM). Herein, SECM techniques are briefly reviewed, including the AFM-SECM technique, to facilitate further development and discovery of highly active, cost-effective, and robust electrode materials for efficient electrolysis and photolysis.

The Analysis of Water Tree Degradations in Underground Distribution Cables Using Image Measurement (가교폴리에틸렌 지중케이블에서 화상계측을 이용한 수트리 열화현상 분석)

  • Kim, Duck-keun;Lim, Jang-Seob;Lee, Jin;Lee, Joon-Ung;Kim, Tae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.19-23
    • /
    • 1998
  • Water tree degradations have been considered as one of the most important causes of failure in underground distribution cables with polymeric insulation. Water tree growth is a preliminary step in the sequence of electrical tree initiation and electrical breakdown of the insulation. In this paper, needle electrode is made use of the etching methods and the pellet type specimen is made to observe the water tree in succession. In previous methods are able to observe the tree degradations without cutting and dyeing. The water tree image is recorded on VTR with CCD camera. The tree length of X, Y axis direction and aging area(treeing area) are calculated with image measurement. As a result of this study, water tree is observed by non-destructive method. Electrical tree is initiated from needle electrode tip only but water tree is initiated from total area of water electrode. Electrical tree owing to water treeing is initiated at low electric field and grown with discontinuously. Namely, water tree is shown up a different characteristics of tree growth.

  • PDF

Influence of Flash-over Voltage on Conductive Particle-Initiated and Solid Dielectric Barrier (고체유전체의 장벽과 도전성 파티클이 섬락전압에 미치는 영향)

  • 이용길;김동의;이세헌;김재호;김정달
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.8 no.3
    • /
    • pp.54-63
    • /
    • 1994
  • In this paper, we fixed to the needle electrode on the plate spacer fabricated the plate electrode of the gap interval 40[mm]and divided into the interval lO[mm]in the gap. When set up the particle and barrier on the material as well as spacer in the each intervaL We investigated that FOV and discharge path to AC, OC positive polarity. The results are as follow. 1) When the barrier is settled on the high potential side and the particle is hidden on the back of barrier, FaV has been increased. 2) When the particle is located on the tip of needle electrode, FaV has been decreased considembly. 3) When the particle is between electrodes. FaV has been decreased because discharge path through the particle.

  • PDF

Improvement of Plasma Reactor Performance for Hydrogen Generation

  • Pavel, Kostyuk;Park, J.Y.;Kim, J.S.;Park, S.H.;Kim, Y.C.;Jeong, M.G.;Lee, H.W.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.519-520
    • /
    • 2006
  • Research was performed to increase the efficiency of a plasma reactor for $H_2$ yield. In the preceding studies $H_2$ was increased by adding Ni as a transitional metal catalyst and $TiO_2$ as a photocatalyst. In these experiments, it was found that distilled water, discharge frequency, and electrode configuration had a significant impact on $H_2$ generation. A substantial amount of hydrogen yield was observed at 2 kHz of discharge frequency and 12 kV of applied voltage. Within this favorable discharge conditions, the weight rate of $TiO_2$ and Ni powders was investigated. Plasma phenomenon was measured by electrical, optical and acoustical devices. It was found that emitted light, electric current and acoustical signals acquired from the discharge demonstrated systematical correlation. Changing the electrode's configuration allowed discharge distribution along the perimeter of the electrode's tip, which increased the density of streamers and plasma energy loadings, as the value of inception voltage for the discharge propagation decreased.

  • PDF