Theory of a Current-Type Electromagnetic Flowmeter for Two-Phase Flow and Numerical Computation of the 3D Virtual Potential Distributions for Annular Flow (2상류용 전류형식 전자기유량계 이론 및 환상류에서의 3차원 가상포텐셜 분포의 수치적 계산)

  • Oh, Byung-Do;Kim, Moo-Hwan;Ahn, Yeh-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.6
    • /
    • pp.714-725
    • /
    • 2003
  • The theory of the current-type electromagnetic flowmeter for a high temporal resolution was developed for two-phase flow measurements. To predict the output of the current-type flowmeter, the three-dimensional virtual potential distribution C and the newly introduced flow pattern coefficient f were derived and computed. The output of flowmeter depends on the liquid conductivity (sensitive to temperature) and flow configurations of the two-phase flow with the sinusoidal excitation over 100 Hz. The flow pattern coefficient was specially devised to separate the dependency on the flow configuration of the two-phase flow from that on the liquid conductivity which can be expressed with the calibration of single-phase flow. Using the finite difference method, the three-dimensional virtual potential distributions were computed for the electrode of finite size. By taking derivative of the virtual potential, the weight functions were evaluated and compared with existing analytic series solution for the point-electrode. There was a reasonable correspondence between the present and existing results. In addition, the flow pattern coefficients were evaluated for annular flows with various film thicknesses, and compared with the experimental results by the impedance spectroscopy. The numerical results agreed well with the experimental data.

Changes in Distribution of Electrical Field in tDCS with Ring Electrode Due to Tissue Anisotropy: a 3D High Resolution Finite Element Head Model Study (경두개직류자극 전기장의 분포 특성에 비등방성 전기 전도율이 미치는 영향 분석 :3차원 고해상도 유한요소 두뇌 모델을 통한 연구)

  • Kim, Sang-Hyuk;Suh, Hyun-Sang;Cho, Young-Sun;Lee, Won-Hee;Kim, Tae-Seong
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.4
    • /
    • pp.305-311
    • /
    • 2011
  • For effective stimulation with tDCS, spatial focality of induced electrical field(EF) and current density(CD) is one of the important factors to be considered. Recently, there have been some studies to improve the spatial focality via different types of electrodes and their new configurations: some improvements using ring electrodes were reported over the conventional pad electrodes. However, most of these studies assumed isotropic conductivities in the head. In this work, we have investigated the effect of tissue anisotropy on the spatial focality of tDCS with the 4 + 1 ring electrode configuration via a 3-D high-resolution finite element(FE) head model with anisotropic conductivities in the skull and white matter. By examining the profiles of the induced EF from the head models with isotropic and anisotropic conductivities respectively, we found that the spatial focality of the induced EF significantly drops and get diffused due to tissue anisotropy. Our analysis suggests that it is critical to incorporate tissue anisotropy in the effective stimulation of the brain via tDCS.

Measurement of Electrical Conductivity of Glass Melter at High Temperature (유리 용융물의 고온에서 전기 전도도 측정)

  • Kim, Taesam;Kil, Daesup;Jung, Hunsaeng;Kang, Eunhee;Yoon, Soksung
    • Analytical Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.775-780
    • /
    • 2000
  • The electrical conductivity of glass melter at high temperature has been measured. The conductivity is an important physical property for the research and the manufacturing process of glass. Because high temperature is an inconvenient situation to measure the conductivity of glass melter, we have made a platinum crucible and electrode and have measured the conductivity at high temperature. KCl solution, of which concentration is adjusted to the conductivity of glass melter, is used to get parameters of the conductivity cell. A measuring circuit is composed with an AC 1 kHz sine wave generator and an operational amplifier. The cell constants are determined from the measured voltages and the equivalent conductances of KCl solution. Various cells are tested to find a suitable shape for high temperature experiment. The results are compared by cell size, electrode depth, and cell configuration. The conductivity of the borosilicate melter is $0.053{\Omega}^{-1}cm^{-1}$ at $1,450^{\circ}C$.

  • PDF

Fabrication of Potentiometric Sodium-ion Sensor Based on Carbon and Silver Inks and its Electrochemical Characteristics (탄소 및 은 잉크 기반의 전위차 나트륨 이온 센서 제조 및 이의 전기화학적 특성)

  • Kim, Seo Jin;Son, Seon Gyu;Yoon, Jo Hee;Choi, Bong Gill
    • Applied Chemistry for Engineering
    • /
    • v.32 no.4
    • /
    • pp.456-460
    • /
    • 2021
  • A potentiometric sodium-ion (Na+) sensor was prepared using a screen-printing process with carbon and silver inks. The two-electrode configuration of the sensor resulted in potential differences in Na+ solutions according to Nernstian equation. The obtained Na+-sensor exhibited an ideal Nernstian sensitivity, fast response time, and low limit of detection. The Nernstian response was stable when the sensor was tested for repeatability and long-term durability. The Na+-selective membrane coated onto the carbon electrode selectively passed sodium ions against interfering ions, indicating an excellent selectivity. The portable Na+-sensor was finally fabricated using a printed circuit system, demonstrating the successful measurements of Na+ concentrations in various real samples.

Desalination of Brackish Water by Capacitive Deionization System Combined with Ion-exchange Membrane (이온교환막을 결합한 축전식 탈염 시스템을 이용한 염수의 탈염)

  • Kim, Yu-Jin;Choi, Jae-Hwan
    • Applied Chemistry for Engineering
    • /
    • v.21 no.1
    • /
    • pp.87-92
    • /
    • 2010
  • Desalination experiments were carried out with two types of cell configuration; a CDI cell constructed with carbon electrodes only and a membrane capacitive deionization (MCDI) cell having a cation-exchange membrane on the cathode surface. The salt removal rate and desalination efficiencies increased linearly with increasing the cell potential. Although the same carbon electrodes were used in the desalination experiments, the MCDI cell showed higher salt removal efficiency than that of the CDI cell. The amount of salt removal for the MCDI cell was enhanced by 33.1~135% compared to the CDI cell, depending on the applied cell potential in the range of 0.8~1.2 V. In addition, the current efficiency for the MCDI cell was about 80%, whereas the efficiency was under 40% for the CDI cell. The higher salt removal efficiency in the MCDI cell was attributed to the fact that ions were selectively transported between the electric double layer and the bulk solution in the MCDI cell configuration.

In-situ spectroscopic studies of SOFC cathode materials

  • Ju, Jong-Hun
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2012.05a
    • /
    • pp.70.1-70.1
    • /
    • 2012
  • In-situ X-ray photoelectron spectroscopy (XPS) and infrared (IR) spectroscopy studies of SOFC cathode materials will be discussed in this presentation. The mixed conducting perovskites (ABO3) containing rare and alkaline earth metals on the A-site and a transition metal on the B-site are commonly used as cathodes for solid oxide fuel cells (SOFC). However, the details of the oxygen reduction reaction are still not clearly understood. The information about the type of adsorbed oxygen species and their concentration is important for a mechanistic understanding of the oxygen incorporation into these cathode materials. XPS has been widely used for the analysis of adsorbed species and surface structure. However, the conventional XPS experiments have the severe drawback to operate at room temperature and with the sample under ultrahigh vacuum (UHV) conditions, which is far from the relevant conditions of SOFC operation. The disadvantages of conventional XPS can be overcome to a large extent with a "high pressure" XPS setup installed at the BESSY II synchrotron. It allows sample depth profiling over 2 nm without sputtering by variation of the excitation energy, and most importantly measurements under a residual gas pressure in the mbar range. It is also well known that the catalytic activity for the oxygen reduction is very sensitive to their electrical conductivity and oxygen nonstoichiometry. Although the electrical conductivity of perovskite oxides has been intensively studied as a function of temperature or oxygen partial pressure (Po2), in-situ measurements of the conductivity of these materials in contact with the electrolyte as a SOFC configuration have little been reported. In order to measure the in-plane conductivity of an electrode film on the electrolyte, a substrate with high resistance is required for excluding the leakage current of the substrate. It is also hardly possible to measure the conductivity of cracked thin film by electrical methods. In this study, we report the electrical conductivity of perovskite $La_{0.6}Sr_{0.4}CoO_{3-{\delta}}$ (LSC) thin films on yttria-stabilized zirconia (YSZ) electrolyte quantitatively obtained by in-situ IR spectroscopy. This method enables a reliable measurement of the electronic conductivity of the electrodes as part of the SOFC configuration regardless of leakage current to the substrate and cracks in the film.

  • PDF

Performance Analysis of Ammonia-Fed Solid Oxide Fuel Cell Using Alternating Flow (교류 흐름 방식을 적용한 암모니아 공급 고체산화물 연료전지의 성능 분석)

  • QUACH, THAI-QUYEN;GIAP, VAN-TIEN;LEE, DONG KEUN;LEE, SUNYOUP;BAE, YONGGYUN;AHN, KOOK YOUNG;KIM, YOUNG SANG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.33 no.5
    • /
    • pp.557-565
    • /
    • 2022
  • The effect of flow configuration in ammonia-fed solid oxide fuel cell are investigated by using a three-dimensional numerical model. Typical flow configurations including co-flow and counter-flow are considered. The ammonia is directly fed into the stack without any external reforming process, resulting in an internal decomposition of NH3 in the anode electrode of the stack. The result showed that temperature profile in the case of counter-flow is more uniform than the co-flow configuration. The counter-flow cell, the temperature is highest at the middle of the channel while in the case of co-flow, the temperature is continuously increased and reached maximum value at the outlet area. This leads to a higher averaged current density in counter-flow compared to that of co-flow, about 5%.

Flexible, Tunable, and High Capacity Ultracapacitor using Nitron-Doped Graphene (질소가 도핑된 그라핀을 이용한 고용량의 조절이 가능한 플렉서블 울트라커페시터)

  • Jeong, Hyung Mo;Shin, Weon Ho;Choi, Yoon Jeong;Kang, Jeung Ku;Choi, Jang Wook
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.163.2-163.2
    • /
    • 2010
  • We developed a simple method to synthesis a nitrogen doped graphene, nitrogen plasma treated graphene (NPG) sheets thought nitrogen plasma etching of graphene oxide (GO). X-ray photo electron spectroscopy (XPS) study of NPG sheets treated at various plasma conditions reveal that N-doping is classified to 3 kinds of binding configurations. The nitrogen doping concentration is at least 1.5 at % and up to 3 at% with changing of ratio of nitrogen configuration in NPG. Our group demonstrate ultracapacitor with high capacity and extremely durable using a NPG sheets that are comparable to pristine graphene supercapacitor, and pseudocapacitor using polymer and metal oxide with redox reaction, capacitance that are three-times higher, and a cycle life that are extremely stable. We also realized flexible capacitor by using the paper electrode that are coated by NPG sheets. NPG paper capacitor presented almost same performance compare with NPG on a metal substrate, and durability is much more enhanced than that. To additionally explain that how different kind of atoms in graphene layers can act as the ion absorption sites, we simulated the binding energy between nitrogen in graphene layer and ions in electrolyte. Increasing the energy density and long cycle life of ultracapacitor will enable them to compete with batteries and conventional capacitors in number of applications.

  • PDF

Influence of Modeling Errors in the Boundary Element Analysis of EEG Forward Problems upon the Solution Accuracy

  • Kim, Do-Won;Jung, Young-Jin;Im, Chang-Hwan
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.1
    • /
    • pp.10-17
    • /
    • 2009
  • Accurate electroencephalography (EEG) forward calculation is of importance for the accurate estimation of neuronal electrical sources. Conventional studies concerning the EEG forward problems have investigated various factors influencing the forward solution accuracy, e.g. tissue conductivity values in head compartments, anisotropic conductivity distribution of a head model, tessellation patterns of boundary element models, the number of elements used for boundary/finite element method (BEM/FEM), and so on. In the present paper, we investigated the influence of modeling errors in the boundary element volume conductor models upon the accuracy of the EEG forward solutions. From our simulation results, we could confirm that accurate construction of boundary element models is one of the key factors in obtaining accurate EEG forward solutions from BEM. Among three boundaries (scalp, outer skull, and inner skull boundary), the solution errors originated from the modeling error in the scalp boundary were most significant. We found that the nonuniform error distribution on the scalp surface is closely related to the electrode configuration and the error distributions on the outer and inner skull boundaries have statistically meaningful similarity to the curvature distributions of the boundary surfaces. Our simulation results also demonstrated that the accumulation of small modeling errors could lead to considerable errors in the EEG source localization. It is expected that our finding can be a useful reference in generating boundary element head models.

A Study on NOx Removal Efficiency Depending on Electrode Configurations of Silent Discharges (무성방전 플라즈마 전극구조에 대한 질소산화물 제거효율 연구)

  • Hyung-Taek Kim;Young-Sik Chung;Myung-Whan Whang;Elena. A. Filimonova
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.3
    • /
    • pp.112-117
    • /
    • 2002
  • A comparative investigation of an experimental and a simulation of chemical kinetics for NOx removal from silent(dielectric-barrier) discharges is presented. Several types of dielectric-barrier discharges were implemented depending upon the configuration of electrodes. The simulation was based on an approximate mathematical model for plasma cleaning of waste gas. The influence of non-uniform distributions of species due to the production of primary active particles in the streamer channel was taken into account. A comparison of observed experimental to the calculated removal efficiency of NOx showed acceptable agreement.