• Title/Summary/Keyword: Electro Magnetic Interference

Search Result 93, Processing Time 0.021 seconds

A Study on Adapted Algorithm for Local Wireless Multimedia Communication and Effective Service (근거리 무선 멀티미디어 통신망 로밍 및 효율적인 서비스에 적합한 알고리즘 연구)

  • Kang Jung yong;Lee Seon keun;Kim Hwan yong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.12A
    • /
    • pp.1349-1355
    • /
    • 2004
  • In tile wireless communication networks although the modulation and demodulation structure with proposed BOWLIS algorithm is a little confusing but we certified that it is fit structure in fast operation processing and high speed wireless LAM system that is more strong on frequence and electro magnetic interference because it process the inputted data within 2.8Us that is faster 0.4Us than 3.2Us in standard form. Also we certified that in the sigtlt of consuming power it is better than pipe-lined structure because of reducing the processing step to 4.

Analysis of the lightning characteristics by the Lightning DB in KOREA (낙뢰위치표정시스템의 낙뢰 DB를 이용한 한반도 뇌격 특이특성 분석)

  • Woo, J.W.;Kwak, J.S.;Shim, E.B.;Lee, G.W.;Kim, K.W.;Kim, B.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1658-1660
    • /
    • 2001
  • Because the overhead transmission lines are exposed to the outdoor weather, the faults of the transmission lines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the statistical distribution of lightning current parameters and the IKL map.

  • PDF

KSR-III 1단 롤 자세제어 시스템 인증시험

  • Jung, Ho-Lac;Jeon, Sang-Woon;Kim, Ji-Hun
    • Aerospace Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.124-132
    • /
    • 2003
  • The function and performance test of the developed sub-system should be conducted before integrating into the total system. For the successful achievement of the flight test, the integration tests of sub-systems must be performed to eliminate and prevent abnormal conditions, which may happen due to ground problems, Electro-Magnetic Interference noises, and so on. This paper describes the certification test procedure and results for the roll axis attitude control system of Korea Sounding Rocket-III.

  • PDF

EMI Mesh Development for the PDP using Electroforming (Electroforming을 이용한 PDP용 EMI 메시 개발)

  • Kwon, H.H.;Beom, M.W.;Lim, S.Y.;Hwang, C.S.;Park, D.S.;Lee, T.W.
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.1
    • /
    • pp.108-113
    • /
    • 2011
  • There are a lot of PDP TV for a plasma discharge pulse voltage generated by the use of electromagnetic waves. EMI mesh film is near Infrared ray caused by malfunction of the remote control intended to prevent this phenomenon. In this study, the formation of fine pattern by making the mold is imprinted on the film sheet. EMI mesh film has been granted by filling in the conductive material region imprinted with electroforming in the manufacture of resistance. The fine patterns fabricated with electroforming facility thickness of homogenization process technology were established to optimize the working conditions.

A Study on the Harmonic Reduction of the Single Phase PWM Converter for High Speed Rail (고속 전철용 단상 PWM 컨버터의 고조파 저감에 관한 연구)

  • 박정배;임훈규;이광운;여형기;유지윤
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.5-9
    • /
    • 1998
  • In the high speed rail system, the distortion of the voltage and the current waveform of the input power line increases the power loss and make a several electro-magnetic problems such as EMI or the interference of the communication line. In this paper, the control scheme of the PWM converter to make a good power factor and to regulated the output voltage as well as to reduce the harmonic component of the input current is proposed. Also a control schem of the PWM converter in the parallel operation to reduce the harmonics of the input current is proposed

  • PDF

Analysis of LPATS-III Error Level and the lightning characteristics in KOREA (LPATS-III의 오차검토 및 한반도 낙뢰발생빈도 분석결과)

  • Woo, J.W.;Shim, E.B.;Kwon, D.J.;Choi, Y.M.;Lee, S.J.;Kim, K.W.;Lee, B.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1772-1774
    • /
    • 2002
  • Because the overhead transmission lines are exposed to the outdoor weather, the faults of the transmission lines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. To study the basic research of the lightning parameters for power system operation, LPATS-III (Lightning Positioning and Tracking System) has been introduced since 1995 in Korea. This paper describes the inspection result about location information error and the statistical distribution of lightning current.

  • PDF

The EMI characteristics research of electrodeless fluorescent lamp ballast (전원회로(무전극 철광등용 안정기)의 전자파장해 특성연구)

  • Lee, Se-Hyun;Kim, Hyun-Sook;Shin, Sang-Wuk;Hwang, Myung-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.211-214
    • /
    • 2002
  • In this paper, We have investigated the EMI (electro magnetic interference) characteristics of electrodeless fluorescent lamp ballast as a ground connection and have measured various waveforms, which can be expressed the disturbance voltages and radiated electromagnetic disturbances. induced the measuring instrument and found that effect of ground connection is the one of the important elements on EMI reduction.

  • PDF

Simulation &Analysis of Conducted EMI in Switched Mode Power Supplies (스위치 모드 파워 서플라이에서의 전도 전자파 장애의 시뮬레이션과 분석)

  • Lee, Dong-Young;Lee, Jae-Ho;Min, Seung-Hyeon;Cho, Bo-Hyung
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.3
    • /
    • pp.122-129
    • /
    • 2001
  • Exact simulation of conducted EMI in switched mode power supplies is proposed. In order to achieve exact simulation, PSPICE active component ABM model and modified transformer model are proposed. Each model parameter is extracted from measurements and data-books. PSPICE simulation results with high frequency PCB pattern model are accordant with EMI measurements for a 50[W] isolated flyback converter. EMI relations of each component and EMI patterns are analyzed.

  • PDF

Consideration on data acquisition and analysis system for using short-circuit tests (디지털 측정 및 분석장치의 적용에 관한 연구)

  • Kim, M.H.;Suh, Y.T.;Kim, D.W.;Kang, Y.S.;Koh, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.38-40
    • /
    • 2001
  • Measuring technology based on the computer and software is used worldwideiy by the aids of remarkably improved digital technology and measuring devices, and the electro- magnetic interference due to high currents and high voltages is being solved by the helps of applied optic instrumentation technology. The automatic acquisition, analysis and storage system of test data is available for utilizing the numerical computation technology. The measuring accuracy and testing efficiency are thus much higher because of the developed technologies. In this paper, the construction of data acquisition system in KERI including measuring devices and its application to the short circuit test are described, and additionally the algorithm of the analyzing program for the automatic process of test data and the results of analyses are described.

  • PDF

Development of Real Time Analysis System about Lightning Information (낙뢰정보 실신간 통계분석시스템 개발)

  • Kwak, J.S.;Woo, J.W.;Shim, E.B.;Kim, K.W.;Kim, Y.S.;Lee, S.J.;Lee, G.W.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.169-171
    • /
    • 2003
  • Because the overhead transmission lines are exposed to the outdoor weather, the faults of the transmission tines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the development of real time analysis system about lightning information.

  • PDF