• Title/Summary/Keyword: Electrical tree

Search Result 589, Processing Time 0.028 seconds

AC Electrical Breakdown Characteristics of an Epoxy/Mica Composite

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.4
    • /
    • pp.200-203
    • /
    • 2012
  • Epoxy/mica composite was synthesized, in order to use it as an impregnation resin in a vacuum pressure impregnation (VPI) process, for manufacturing a high voltage rotary machine. The average particle size of the mica was 5~7 ${\mu}m$ and its content was 0, 20, 30 and 40 wt%. A plasticizer or a low molecular aliphatic epoxy was also used, to decrease the viscosity of the composite. The AC electrical breakdown strength was estimated in sphere-to-sphere electrodes, and the electrical breakdown data were estimated by Weibull statistical analysis. The electrical breakdown strength became higher with the addition of mica; and that of the system with 20 wt% mica was highest. The electrical breakdown strength of the system with an aliphatic epoxy was higher than that of the system with a, plasticizer.

Electrical Degradation Pattern Analysis according to XLPE Cable (XLPE 케이블의 전기적 열화 패턴 분석)

  • Min, Chi-Hyun;Gwak, Dong-Sun;Chun, Hyun-Kwon;Choi, Jin-Wook;Kim, Young-Suk;Kim, Sun-Gu;Kim, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.114-120
    • /
    • 2008
  • XLPE cable is using insulator for Cross Linked Polyethylene(XLPE), because insulation Performance is superior and easy comparatively. Need systematization of accident transaction for electrical equipment accident, It is no disposal standard for defect of manufacture and second to accidents. in this paper deals with the change of XLPE cable insulation. To understand the electrical properties of XLPE insulation. Made of XLPE block sample, Penetration fracture Sample and flashover sample. Ogura needles having tip radius of $10[{\mu}m]$ were inserted into each sample. AC voltage of 1[kV/sec] increased at 60[Hz] were apple to breakdown sample and flashover sample. AC voltages of 12[kV], 17[kV] at 60[Hz] were a lied to XLPE block sample. The electrical properties of specimens were measured were measured from initiation of tree and breakdown to their characteristics were analyzed.

Electrical Characteristic of Blend with LLDPE and EVA Due to Mixing Ratio (혼합비에 따른 선형저밀도 폴리에틸렌과 에틸렌비닐아세테이트 블랜드의 전기적 특성)

  • 신종열;이충호;홍진웅
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.6
    • /
    • pp.525-532
    • /
    • 2001
  • In this paper, physical properties and electrical characteristics of linear low density polyethylene(LLDPE) films blended with ethylene vinyl acetate(EVA), containing polar groups within it, were investigated to improve defects of polyethylene(PE) such like space charge accumulation and tree growth. Blending method changes super-structure of LLDPE, having a great influence on electrical characteristics. For analysis of physical properties, FTIR, XRD and DSC methods were executed, and for electrical characteristics, volume resistivity and dielectric strength were measured with the varying temperature. From the results, it is confirmed that bled specimens tend to be safe to varying temperature, and specially of 70:30 and 50:50 have a good performance.

  • PDF

A Study on the Implementation and the Performance Evaluation of the Train Communication Network (전동차용 통신 네트워크 프로토콜 구현 및 성능평가에 관한 연구)

  • Lee, Sang-Chul;Park, Jae-Hyun;Chang, Nae-Hyuck
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.12
    • /
    • pp.1580-1588
    • /
    • 1999
  • This paper evaluates the real-time performance of the Train Communication Network (TCN) that consists of WTB and MVB. A run-time scheduling algorithm for the hard-real time communication was proposed and its performance was evaluated. Also, a new addressing method and the adaptive tree algorithm were suggested to enhance performance. The overall performance was evaluated by computer simulation using Arena.

  • PDF

An Expert System for Security Assessment in Distribution System (배전계토에서의 안전도 평가를 위한 전문가 시스)

  • Park, Byoung-youn;Kim, Se-Ho;Moon, Young-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.2
    • /
    • pp.179-188
    • /
    • 1994
  • This paper deals with implementation of an expert system to obtain an optimal plan of load transfer for fault restoration with the capability of security monitoring and assessment in distribution systems. Based on the technique of load transfer tree analysis, the proposed expert system can afford to assist system operators in proposing an optimal plan of load transfer for fault restoration, In paticular, an application of the proposed ES to practical distribution systems yields an optimal load transfer plan which ensures system security by considering security assessment for contingency of feeders and main transformers in the knowledge based sense.

Temperature Dependence of AC Treeing Deterioration in DGEBA/MDA/GN System (DGEBA/MDA/GN 계에서 AC 트링열화의 온도의존성)

  • 안현수;심미자;박수길;김상욱
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.425-428
    • /
    • 1996
  • Treeing deterioration which is one of the main cause of breakdown in insulating materials is affected by temperature, applied voltage and frequency. In this study, GN was introduced to improve impact strength of DGEBA/MDA system and the temperature dependence of AC treeing deterioration in this system was investigated. Dielectric breakdown strength decreased with the increment of temperature. As temperature increased, the growth rate of tree Increased.

  • PDF

n Expert System for Voltage Control (전압 제어를 위한 전문가 시스템)

  • 백영식;사공일
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.9
    • /
    • pp.684-692
    • /
    • 1989
  • An expert system which is a part of artificial intelligence is developed for controlling violated voltages. Control equipments such as shunt capacitors, inductors, transformer tap changers and generator voltages are utilized. A breadth-first search method is used. A sensitivity tree is suggested to minimize the number of control devices. If the voltage condition program should be utilized to efficiently solve the problem. The expert system uses PROLOG and for the sub-program C language is used. This expert system, when applied to an 8 bus power system, shows satisfactory results.

  • PDF

A Study on the Image Processing for Effective Insulation Material Degradation Testing (효과적인 절연재료 열화검사를 위한 영상처리에 관한 연구)

  • 정기봉;오무송;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.230-233
    • /
    • 1999
  • Because Insulation material is play an important part for normal work of electricity equipment, the study is advanced, but as the voltage of electricity system is raising, we required that new lnsulation material. They have excellent specific against high stress, namely the study of insulation increase and prevention diagnosis of insulation degradation of Epoxy or XLPE and so on. In this thesis. I utilize image processing technique for effective inspection of insulation material degradation.

  • PDF

BF Gray Quadtree : Efficient Image Representation Method (Breadth First Gray Quadtree:화상의 효율적 표현법)

  • Lee, Geuk;Lee, Min-Gyu;Hwang, Hee-Yeung;Lee, Jung-Won
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.5
    • /
    • pp.494-499
    • /
    • 1990
  • A new compact hierarchical representation method image is proposed. This method represents a binary image with the set of decimal numbers. Each decimal number represents the pattern of nonterminal node(gray node) in the quadtree. This pattern implies the combination of its four child nodes. The total number of gray nodes is one third of that terminal nodes. We show that gray tree method is efficient comparing with others which have been studied.

  • PDF

Heuristic Search in Overcurrent Protection Coordination of Power Distribution Systems (경험적 탐색에 의한 배전계통 보호기기 정정협조)

  • 이승재;박영문;이정원
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.2
    • /
    • pp.135-143
    • /
    • 1991
  • The setting problem of protective devices in power distribution systems is a combinatorial search problem involving a lot of trial & errors to search for a proper solution which has a great impact for the system reliability. This paper discusses the nature of the problem and proposes a scheme to prune the decision tree achieving the efficient search for a setting solution by applying heuristic rules which utilize pattern informations of backup and primary devices. Its effectiveness is demonstrated through many tests on real systems.

  • PDF