• Title/Summary/Keyword: Electrical tree

Search Result 588, Processing Time 0.032 seconds

The Analysis on the Chaos/Fractal of Electrical Tree Generated at Power Cable (전력케이블에서 발생하는 전기트리의 Chaos/Fractal 해석)

  • Lim, Jang-Seob;Kim, Jin-Gook;Kim, Hyun-Jong;Lee, Jin
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11b
    • /
    • pp.19-22
    • /
    • 2004
  • Growth of Electrical Tree Under 50Hz~60Hz high electric stress has been studied on the Occurrence of a Pattern, to the Progression Speed at Y axis of electrical Tree. CCD Images of evolving tree structures could be obtained in both systems. Electrical Treeing was found to occur reproducibly, but in a markedly different manner in the two morphologimlly different but chemically identical materials. For the measurement of Electrical Tree, a visual measurement with an optical microscope has been used to explain breakdown mechanism in High-voltage systems.

  • PDF

Properties of PD Pulses Accompanying with Bush-type Tree in LDPE (저밀도 폴리에틸렌에서 부시형 전기트리에 수반되는 부분방전 펄스의 특성)

  • 강성화;박영국;정수현;이광우;임기조
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.12
    • /
    • pp.1055-1059
    • /
    • 1998
  • The correlation between the propagation of electrical tree and distributions of partial discharge(PD) pulses accompanying with electrical tree of bush type in low density polyethylene were discussed. We measured the growth of electrical tree by using optical microscope and PD data simultaneously. The PD data detected and analyzed were PD magnitude, repetition rate, average discharge power, average phase angle, and $\psi$-q-n distribution pattern. The average discharge power and repetition rate of PD had good linear relation with area of tree. Repetition rate and peak discharge magnitude and width of discharge phase angle increased with the tree.

  • PDF

The Influence of Surface Modified Nano Alumina for Electrical Treeing in Epoxy Insulation (에폭시 절연의 전기적 트리잉에 관한 표면 개질된 나노알루미나의 영향)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.7
    • /
    • pp.1218-1224
    • /
    • 2016
  • This paper presents the results of a study on the effect of surface modified alumina nanocomposites on electrical tree growth in epoxy insulation. Treeing experiments were conducted at a fixde AC voltage (500kV/mm, 10kV/60Hz)on unfilled epoxy sample as well as epoxy nanocomposites of 4 types with different loading and surface modified GDE gram. Time for tree growth as well as tree propagation length were studied. The results show that there is a significant improvement tree propagation time compare unfilled epoxy to epoxy nano alumina composites. Different tree propagation shapes as well as slower tree growth with 4 types nano alumina composites were observed.

Analysis on Pattern of Electrical Tree Using Fractal (프랙탈을 이용한 전기트리의 패턴분석)

  • Kim, Duck-Keun;Lim, Jang-Seob;Oh, Soo-Hong;Min, Youg-Ki;Lee, Jin;Kim, Tae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.712-715
    • /
    • 1999
  • Treeing has a profit to observe processing electrical breakdown because it gives degradation steps of insulation material by optical method. But, reappearance properly of treeing is not so good and precise quantization of tree growth is not so easy because tree Patterns are very complicate. The study on tree growth using image processing is predicted to precision of tree degradation and possible to quality measurement of tree pattern. In this paper, degradation steps are analyzed by image processing, therefore precision and realiability of tree growth are increased. Also, processing of tree degradation is quantized by fractal.

  • PDF

Fractal Analysis and Tree Characteristics in XLPE (XLPE에서의 트리특성 및 프랙탈 해석)

  • Lim, Jang-Seob;Kim, Tae-Sung;Lee, Joon-Ung
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.450-452
    • /
    • 1995
  • The Tree observation technique is being highlighted as a research area for deterioration of insulation because of high-voltage power system. For the measurement of tree, image processing is actively studied as a experimental technique of electrical tree, because the conventional directed visual method is impossible to analyze on tree degradation area and tree pattern. In this paper, we have developed the tree measuring system using image processing. By using an image processing technique, the treeing can be easily measured and effectively observed.

  • PDF

PD Characteristic of Electrical Tree Generated by Internal Defects (내부결함에서 나타나는 전기트리의 부분방전 특성)

  • Kim, Byong-Chul;Yoon, Jae-Hun;Park, Seong-Hee;Kang, Seong-Hwa;Lim, Kee-Jo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1387-1388
    • /
    • 2007
  • Solid insulation exposed to voltage is degraded by electrical tree process. And the degradation of the insulation is accelerated by voltage application. For this experiment, specimens of electrical tree models were made by three types of XLPE (cross-linked polyethylene). And distribution characteristics of degraded stages are studied too. As a method of detecting and data process, discharge data was acquired from PD detecting system (Biddle instrument). And microscope and digital camera were used to observe the morphologies of the electrical tree to divide stages of the tree. The system presents statistical distribution as phase resolved. Moreover the processing time of electrical tree is recorded to know the speed of degradation according to voltage.

  • PDF

Electrical Properties of XLPE/VLDPE B1ends (XLPE/VLDPE 블렌드의 전기적 성질)

  • 고정우;서광석;김종은;강형식;김덕주
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.215-218
    • /
    • 1998
  • XLPE/VLDPE (Crosslinked polyethylene/very low density polyethylene) blends were prepared by a twin screw extruder and their electrical properties such as water tree and breakdown characteristic were measured. it was found that both water tree and breakdown characteristics of XLPE were improved by the addition of VLDPE to polyethylene. It was also found that the extent of improvement of electrical properties by the addition of VLDPE to polyethylene depends on the type and concentration of VLDPE.

  • PDF

PD Characteristic of Electrical Tree Generated by Inside Void Defect (내부 보이드 결함에서 발생하는 전기트리의 부분방전 특성)

  • Park, Seong-Hee;Jung, Hae-Eun;Kang, Seong-Hwa;Lim, Kee-Jo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.334-335
    • /
    • 2006
  • Solid insulation exposed to voltage is degraded by electrical tree process. And the degradation of the insulation is accelerated by voltage application. For this experimental, specimen of electrical tree model is made by XLPE (cross-linked polyethylene). And the size of the specimen is 7*5*7 $mm^3$. Distance of needle and plane is 2 mm. Voltages applied for acceleration test are 12 kV to 15 kV. And distribution characteristic of degraded stage is studied too. As a PD detecting and data process, discharge data acquire from PD detecting system (Biddle instrument). The system presents statistical distribution as phase resolved. Moreover the processing time of electrical tree is recorded to know the speed of degradation according to voltage.

  • PDF

Properties of Partial Discharge accompanying with Electrical Tree in LDPE (저밀도 폴리에틸렌에서 전기트리에 수반되는 부분방전의 특성)

  • 이광우;박영국;강성화;장동욱;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.234-238
    • /
    • 1999
  • The correlation between shape of electrical trees and partial discharge(PD) pulses in low density polyethylene(LDPE) were discussed. We observed growth feature of electrical tree by using optical microscope. On the basis of experimental results of measurements of trees occurring in the needle-plane arrangement with needle shape void and without needle shape void , statistical quantities are derived, which are relevant to PD pulse amplitude and phase. The PD quantities detected by partial discharge detector. we were analyzed q-n distribution pattern and $\psi$ -q-n distribution pattern. In this experiment, electrical trees in the needle-plane arrangement with needle shape void propagated branch type tree and in the needle-plane arrangement without needle shape void propagated bush type tree

  • PDF

An Effect of the Salt Solution on the Water Tree Propagation in Polyethylene (폴리에틸렌 내에서 워터트리가 확산하는데 염용액이 미치는 영향)

  • Koo, Ja-Yoon
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.11
    • /
    • pp.436-439
    • /
    • 1985
  • An effect of the salt solution on the Water Tree Propagation was shown systematically from the actions of the salt concentration in deionized water. It may be able to suggest that the tree propagation is possibly to be connected with an intervention of the electrochemical or chemical actions of the salt solution on water tree propagation, which may likely depend on the growth level of the trees. We have pointed out that it is necessary to study the structure of water tree under the electrical stress.

  • PDF