• Title/Summary/Keyword: Electrical response

Search Result 3,697, Processing Time 0.042 seconds

Optimal Design of Permanent Magnet Linear Synchronous Motor(PMLSM) Considering Multiple Response by Response Surface Methodology(RSM) (영구자석 선형 동기전동기(PMLSM)의 반응표면법(RSM)을 이용한 다중 반응 최적설계)

  • Kim Sung-Il;Nam Hyuk;Kim Young-Kyoun;Hong Jung-Pyo;Cho Han-Ik
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1097-1099
    • /
    • 2004
  • This paper deals with the optimal design of a slotless type of permanent magnet linear synchronous motor (PMLSM). Response surface methodology, one of the optimization methods, is used to consider multiple response of the PMLSM. That is, it is applied to obtain more average thrust and less thrust ripple than prototype PMLSM. To analyze quickly, characteristic analysis of the PMLSM is performed by space harmonic method and final results of optimized PMLSM are compare with those of prototype PMLSM through finite element analysis.

  • PDF

A Survey on the Performance of Demand Response Programs in US Electricity Markets (미 전력시장의 수요응답(Demand Response) 성과(Performance) 조사)

  • Kim, Jin-Ho;Park, Jong-Bae;Won, Jong-Ryul;Park, Jun-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.269-271
    • /
    • 2004
  • 전력산업 구조의 변화와 전력수급의 안정성 확보를 위해, 다양한 전원개발에 대한 연구가 시도되고 있다. 본 연구에서는 현재 미국에서 시행하고 있는 수요응답자원(Demand Response Resource)에 대한 수요응답 프로그램(Demand Response Program)의 성과를 조사하고 이를 분석하였다. 미 연방에너지 규제위원회(FERC)의 시장표준안과 각 주의 공익규제위원회(PUC)에 규제에 의해 대부분의 미 전력시장에서는 이러한 수요응답 프로그램을 시행하고 있다. 본 논문에서는 미국 전력시장을 대표하는 New England ISO, PJM, 그리고 NYISO 세 곳의 수요응답 프로그램 효과를 조사하였다. 본 논문에서는 수요응답 프로그램의 참여자 수와 수용응답 이벤트 발생 건 수, 총 차단부하량, 평균 차단부하량, 그리고 지급액의 관점에서 수요웅담 프로그램의 효과를 조사하였다.

  • PDF

Survey for the Trend of Demand Response Program (Demand Response Program의 동향 분석)

  • Kim Hyeong Jung;Son Hag Sig;Kim In Soo;Im Sang Kug;Park Jong Bae;Shin Jopng Rin
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.671-673
    • /
    • 2004
  • Demand Response Programs (DRP) are critical to the operation of efficient and competitive energy markets. and provide critical market improvements to Independent System Operators (ISO). To all energy market Participants, they Provide savings and cost reductions when end users have the ability to respond to wholesale prices. Now, in the competitive electricity market, DRP is classified by Emergency and Economic DRP to reduce costs and maintain reliability. In this paper, we survey the trend of Demand Response Program over the world and compare the practical performance among the markets in US.

  • PDF

Capless Low Drop Out Regulator With Fast Transient Response Using Current Sensing Circuit (전류 감지 회로를 이용한 빠른 과도응답특성을 갖는 capless LDO 레귤레이터)

  • Jung, Jun-Mo
    • Journal of IKEEE
    • /
    • v.23 no.2
    • /
    • pp.552-556
    • /
    • 2019
  • This paper present a capless low drop out regulator (LDO) that improves the load transient response characteristics by using a current regulator. A voltage regulator circuit is placed between the error amplifier and the pass transistor inside the LDO regulator to improve the current characteristics of the voltage line, The proposed fast transient LDO structure was designed by a 0.18 um process with cadence's virtuoso simulation. according to test results, the proposed circuit has a improved transient characteristics compare with conventional LDO. the simulation results show that the transient of rising increases from 1.954 us to 1.378 us and the transient of falling decreases from 19.48 us to 13.33 us compared with conventional capless LDO. this Result has improved response rate of about 29%, 28%.

Multi-Object Optimization of the Switched Reluctance Motor

  • Choi, Jae-Hak;Kim, Sol;Kim, Yong-Su;Lee, Sang-Don;Lee, Ju
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.4
    • /
    • pp.184-189
    • /
    • 2004
  • In this paper, multi-object optimization based on a progressive quadratic response surface method (PQRSM) and a time stepping finite element method (FEM) is proposed. The new PQRSM and FEM are able to decide optimal geometric and electric variables of the switched reluctance motor (SRM) with two objective functions: torque ripple minimization and average torque maximization. The result of the optimum design for SRM demonstrates improved performance of the motor and enhanced relationship between torque ripple and average torque.

A study on the dynamic characteristic of voltage and current in a feeder system in case of cause contact loss on driving an electrical railway vehicle (전기차량 주행 중 이선상태에 따른 급전계통의 전압, 전류 동특성 연구)

  • Kim, Jae-Moon;Park, Young;Kim, Yang-Su;Lee, Jong-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2215-2216
    • /
    • 2011
  • In this study, the dynamic characteristic of a contact wire and pantograph suppling electrical power to electrical railway vehicle is investigated from an electrical response point of view. To analysis voltage and current waveforms by induced contact loss phenomenon on driving electrical railway vehicle, a hardware Simulator which considered contact loss between contact wire and the pantograph as well as contact wire deviation is developed. It is confirmed that a contact wire and pantograph model are necessary for studying the dynamic behavior of the pantograph system. Throughout prototype simulator and contact wire and catenary wire experiments, it is confirmed that current waveforms is distorted by contact loss phenomenon and in case of driving electrical railway vehicle.

  • PDF

Electrical Conduction Characteristics of Stearic Acid LB Films Using Distance of Electrode (전극 간격 변화에 대한 Stearic acid LB막의 전기 전도 특성)

  • Lee, Eul-Sik;Kim, Do-Kyun;Choi, Yong-Sung;Chang, Jeong-Soo;Kwon, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1506-1507
    • /
    • 1998
  • Stearic acid LB films was deposited by LB technique. The deposition status of LB films were verified by UV absorbance which was increased in proportion to the number of layers. And, I-V characteristics were measured to investigate the response properties between LB films and organic gases using the distance of electrodes. The current was increased with the applied voltage but decreased as increasing the distance of electrodes. The conductivity of stearic acid LB films using the distance of electrodes was $10^{-8}$[S/cm], which corresponds to that of the semiconductor.

  • PDF

Evaluation of Magnetic Field Components Produced by Electric Machine Operations (전기기기의 조작시 발생되는 자계성분 평가에 관한 연구)

  • Lee, Bok-Hee;Park, Hyung-Ki;Cheon, Duck-Kyu;Paek, Yong-Hyun;Cheong, Seung-Su
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1993.05a
    • /
    • pp.68-71
    • /
    • 1993
  • In this study, decay time and frquency response characteristics of Self-Integrating Magnetic Sensor were investigated, decay time is 4.4[ms], frequency band that could be measuring is from 40[Hz] to 1[kHz]. The magnetic field components produced by operation of electric machines is measured and analyzed.

  • PDF

Performance Enhancement of a Sensorless Drive for Brushless DC Motor Using Digital Filter (디지틀 필터를 이용한 브러시리스 직류 전동기용 센서리스 드라이브의 성능 향상에 관한 연구)

  • Yeo, H.G.;Lee, K.W.;Park, J.B.;Kim, T.H.;Lee, I.H.;Yoo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.490-492
    • /
    • 1997
  • This paper describes a digital sensorless drive of permanent magnet brushless DC (PM BLDC) motors. The sensorless drive adopts a digital filter - moving average finite impulse response filter for accurate estimation of commutation time. Experimental results show that the performance of the proposed sensorless drive is superior to that of the sensorless drive without filtering.

  • PDF

A New Assessment for the Total Harmonic Contributions at the Point of Common Coupling

  • Han, Jong-Hoon;Lee, Kyebyung;Song, Chong Suk;Jang, Gilsoo;Byeon, Gilsung;Park, Chang-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.6-14
    • /
    • 2014
  • A new method to determine the total harmonic contributions of several customers and the utility at the point of common coupling is presented. The proposed method can quantify the individual harmonic impact of each suspicious harmonic source at the point of common coupling. The individual harmonic impact index is then used to assess the total harmonic contribution of each harmonic source. This index can be calculated by the results processed from instantaneous harmonic voltage and current phasor values. The results demonstrate the performance of the proposed method in terms of steady-state accuracy and response to time-varying operating conditions. The proposed index can be used for billing purposes to control harmonic distortion levels in power systems.