• Title/Summary/Keyword: Electrical resistance change

Search Result 502, Processing Time 0.027 seconds

Broad and stage-based sensing function of HCFRP sensors

  • Wu, Z.S.;Yang, C.Q.
    • Smart Structures and Systems
    • /
    • v.3 no.2
    • /
    • pp.133-146
    • /
    • 2007
  • This paper addresses a new type of broad and stage-based hybrid carbon fiber reinforced polymer (HCFRP) sensor that is suitable for the sensing of infrastructures. The HCFRP sensors, a type of composite sensor, are fabricated with three types of carbon tows of different strength and moduli. For all of the specimens, the active materials are carbon tows by virtue of their electrical conductivity and piezoresistivity. The measurement principles are based on the micro- and macro-fractures of different types of carbon tows. A series of experiments are carried out to investigate the sensing performances of the HCFRP sensors. The main variables include the stack order and volume fractions of different types of carbon tows. It is shown that the change in electrical resistance is in direct proportion to the strain/load in low strain ranges. However, the fractional change in electrical resistance (${\Delta}R/R_0$) is smaller than 2% prior to the macrofractures of carbon tows. In order to improve the resistance changes, measures are taken that can enhance the values of ${\Delta}R/R_0$ by more than 2 times during low strain ranges. In high strain ranges, the electrical resistance changes markedly with strain/load in a step-wise manner due to the gradual ruptures of different types of carbon tows at different strain amplitudes. The values of ${\Delta}R/R_0$ due to the fracture of high modulus carbon tows are larger than 36%. Thus, it is demonstrated that the HCFRP sensors have a broad and stage-based sensing capability.

Series Resistance Change by Partial Shading in a-Si Thin Film Photovoltaic(PV) Module (부분 음영에 따른 a-Si Thin Film Photovoltaic(PV) Module의 직렬저항변화)

  • Shin, Jun-Oh;Jung, Tae-Hee;Kim, Tae-Bum;Woo, Sung-Chul;Yun, Na-Ri;Kang, Ki-Hwan;Han, Deuk-Young;Ahn, Hyung-Keun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.11
    • /
    • pp.901-905
    • /
    • 2010
  • PV module has many power loss factors, and series resistance is the most important elements of them. It is therefore easy to expect the partial shading decrease the lifetime of the semiconductor depletion layer in thin film PV module. Different shading losses could be related with the hot spot which is critical in expecting the reliability issue. In this paper we have modelled the series resistance of the PV module with both different direction of the cell line and shading area of the panel. From the results, thin film a-Si PV module has shown different properties by shading direction.

Abnormal behaviors in electrical conductions of SOI substrate by thermal annealing temperature (열처리에 따른 SOI 기판에서의 전기전도특성의 이상 거동)

  • Cho, Won-Ju
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.126-127
    • /
    • 2008
  • The effects annealing conditions on the electrical conductions of SOI substrate were studied. The reversible change of resistance and carrier concentration in accordance with the annealing temperature were observed for the first time in SOI substrate. The thermal donors due to interstitial oxygen atoms contribute the change of resistance and carrier concentration. Final1y, we show that the furnace annelaing at $500^{\circ}C$ at final heat treatment stage is effective for eliminate the thermal donor effects in SOI substrate.

  • PDF

Adaptive Vector Control for Induction Motor Using Parameter Estimation (매개변수 추정에 의한 유도전동기의 적응 벡터제어)

  • Lee, Y.J.;Kim, H.J.;Oh, W.S.;Kim, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.363-366
    • /
    • 1990
  • In the indirect vector control method, the rotor resistance variation caused by operating temperature change is an undesirable nature. A new adaptation algorithm to compensate for the rotor resistance change based on the on-line estimation of field vector which requires the measurements of stator voltage and rotor speed is presented in this paper. Also minimum variance controller is presented for the adaptive control performance. This algorithm has been tested by simulating the induction machine using a digital computer and the results are discussed.

  • PDF

The Aging Characteristics of Polymer Electrical Insulation Materials bv UV Radiation and Salt Water Spray (옥외용 고분자 전기절연재료의 염수 및 UV조사에 의한 열화 특성)

  • 최남호;한상일;한상옥;박강식;김종석;박양범
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.221-224
    • /
    • 1997
  • In this study we investigated the acting characteristics of Polymers for electrical insulation by UV radiation and salt water spray treatment. We used the Polymers such as EPDM, SR. PTFE. EVA. We measured contact angle and surface resistance to know the aging characteristic of Polymer surface. And we use SEM to observe the change of the surface shape. Dry flashover voltage test impulse voltage test were carried for the polymer insulator(EVA) . Through this experiment and the analysis we could know the polymers have a good resistance to weathering conditions like as salt spray UV irradiation and mix of them. And we can compare the aging characteristics between Polymers. As a result, we could know that the surface characteristics of PTFE is better than the other. And the degree, electrical characteristics is affected by change of surface shape is not big.

  • PDF

Study on the application of antenna method for the criterion test of insulator arc resistance (절연체의 내아크성 평가를 위한 안테나 기법의 적용에 관한 연구)

  • Lee, K.W.;Kim, M.Y.;Kang, S.H.;Lim, K.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.57-60
    • /
    • 2004
  • Electrical arc is the final stage of insulation breakdown and has high current density which cause heat and light in insulator. Insulator under electrical arc lost its insulating strength and eternal damages. Conventional criterion of electrical arc resistance in Standards have depended on the change of sound pressure and light color after damages on insulator by electrical arc. The recognition of these changes is done by human himself which was very subjective and resulted in some error to judge whether insulator has damages or not. This paper has shown that antenna method is the appropriate measure to judge electrical arc resistance for insulator. Antenna measures the electromagnetic waves radiated from tungsten electrodes with 6mm gap regulated by KSC2130. Applied voltage cross two tungsten electrodes have two different methods such as 1/8 10 and continuous 10mA. Signal amplitudes obtained by antenna has diminished after the damage of insulator, which will provide objective and good way to judge the electrical arc resistance.

  • PDF

Electrical Resistance Measurement in Characterizing the Internal Damage of Carbon Nanotube/Polypropylene Nanocomposites (전기저항 측정법을 이용한 탄소나노튜브/폴리프로필렌 나노복합재료의 내부 손상 예측)

  • Kim, Hak-Soo;Kwon, Dong-Jun;Wang, Zuo-Jia;Gu, Ga-Young;Kim, Dae-Sik;Lee, Chun-Soo;Park, Joung-Man
    • Composites Research
    • /
    • v.26 no.3
    • /
    • pp.201-206
    • /
    • 2013
  • The electrical resistance measurement was investigated as a damage monitoring method. In this study, 0.5 wt% Carbon nanotube reinforced polypropylene (CNT/PP) composites were evaluated under compressive fatigue loading. The shape of specimens was $20^{\circ}$ curved round type. Compression strength and electrical resistance were measured at different sections of specimen during compression. The microcracks of CNT/PP composites were detected based on the changing ratio of electrical resistance. Micro-damage during compressive fatigue test could be detected by electrical resistance measurements. The reason is that the contact points of CNTs in composites decreased under fatigue loading. During compressive fatigue test, larger change of electrical resistance was detected at the microcrack sections. It was proved that microcracks could be detected by electrical resistance measurement under compression test, whereas the real delamination parts were consistent with the predicted results by electrical resistance measurement.

Electrical Properties of Ag-coated Conductive Yarns Depending on Physical and Chemical Conditions (물리화학적 조건에 따른 은코팅 전도사의 전기적 특성)

  • Ryu, Jong-Woo;Jee, Young-Joo;Kim, Hong-Jae;Kwon, Seo-Yoon;Yoon, Nam-Sik
    • Textile Coloration and Finishing
    • /
    • v.23 no.1
    • /
    • pp.43-50
    • /
    • 2011
  • Electrically conductive yarn coated with silver particles are widely used to make smart wear but recent studies on smart fabrics are focused on measuring method of electrical characteristics and improving technologies of its electric properties. Also durability of conductive yarn with environmental change was also important work to make smart fabric. We compared resistance changes of silver coated conductive yarns under various physical and chemical conditions such as repeated strain, heat exposure and pH for basic informations on smart wear manufacturing process. And we deduct that repeated strain among the physical conditions was most effective factors on yarn resistance change and the low resistance change was observed with increasing the number of filaments in identical yarn fineness.

Characterization of Electrical Resistance for SABiT Technology-Applied PCB : Dependence of Bump Size and Fabrication Condition (SABiT 공법적용 인쇄회로기판의 은 페이스트 범프 크기 및 제작 조건에 따른 전기 저항 특성)

  • Song, Chul-Ho;Kim, Young-Hun;Lee, Sang-Min;Mok, Jee-Soo;Yang, Yong-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.4
    • /
    • pp.298-302
    • /
    • 2010
  • We investigated the resistance change behavior of SABiT (Samsung Advanced Bump interconnection Technology) technology-applied PCB (Printed Circuit Board) with the various bump sizes and fabrication conditions. Many testing samples with different bump size, prepreg thickness, number of print on the formation of Ag paste bump, were made. The resistance of Ag paste bump itself was calculated from the Ag paste resistivity and bump size, measured by using 4-point probe method and FE-SEM (Field Emission Scanning Electron Microscope), respectively. The contact resistance between Ag paste bump and conducting Cu line were obtained by subtracting the Cu line and bump resistances from the measured total resistance. It was found that the contact resistance drastically changed with the variation of Ag paste bump size and the contact resistance had the largest influence on total resistance. We found that the bump size and contact resistance obeyed the power law relationship. The resistance of a circuit in PCB can be estimated from this kind of relationship as the bump size and fabrication technique vary.

Analysis of Thermal Characteristics and Insulation Resistance based on Usage Environment and Current Value of Electrical Socket Outlet (전기콘센트의 사용환경과 전류값에 따른 열적특성 및 절연저항 분석)

  • Kim, Kyung Chun;Kim, Doo Hyun;Kim, Sung Chul
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.22-30
    • /
    • 2019
  • In 2018, overload, overcurrent, insulation aging, and a contact failure caused 659 electric fires. There is almost no failure of electrical socket outlets during their manufacturing or installation period. After several months or several years, overload or overcurrent of electrical socket outlets leads to a contact failure or short circuit which causes an electric fire. Therefore, this paper analyzed for thermal characteristics based on a current value and the change in insulation resistance along with a temperature rise caused by electrical socket outlets and the state of laboratory use in workplaces. As a results, regarding the thermal characteristics based on the current value of each installation year, a temperature increase was related to a current value, an installation year, and whether the contact unit is corroded. Insulation resistance began to decrease when a temperature increased to a certain level. With a lapse of installation year, the temperature at which insulation resistance began to decrease was lowered. This paper can be applicable for the survey data about electrical socket outlet induced fire accidents and management guidelines.