• 제목/요약/키워드: Electrical power monitoring

검색결과 903건 처리시간 0.03초

변전소 자동화 환경에서 웹 기반 전기품질 감시 시스템 (A web-based power quality monitoring system in the Substation Automation System)

  • 박동호;임성정;신재항;임성일;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.378-380
    • /
    • 2004
  • Along with the increase of the importance of power quality, many various systems are dedicated in the analysis of power quality nowadays. But there still exists the same problems for realizing such kind of analysis systems well. One is the customization of the power quality measure devices; The other is an economic problem. This paper presents the usefulness and the advantage of the ICD (Intelligent Electronic Device) as the measure device of power quality And this paper detailedly describes the development procedure of web-based power quality monitoring system through ActiveX controls. Now this power quality monitoring system is already applied to the substation automation system.

  • PDF

IoT 활용 이동착탈식 열화 진단 장치 개발 (Development of Moving and Attaching Diagnosis Device Using IoT)

  • 가출현;이동규;김진사
    • 한국전기전자재료학회논문지
    • /
    • 제30권9호
    • /
    • pp.596-601
    • /
    • 2017
  • The advancement and diversification of urban functions has caused an increasing need to improve the reliability of power supplies. The diversification of urban areas causes social disruptions by paralyzing urban functions during power outages. A large power outage occurs in the event of an accident, owing to the subduction of distribution lines. Therefore, in recent years, for the sake of the environment and safety, the safety diagnosis of electric power facilities has become an important issue. In this system, because thermal information changes rapidly during unattended monitoring owing to heat concentration phenomenon due to abnormal load or deterioration, studies have been conducted on the development of a device that can notify the manager at all times.

계통 연계형 태양광 발전 시스템의 부하 무효전력 보상이 적용된 단독운전 인지법 (The Anti-Islanding Method with Compensation of Load Reactive Power for Grid-connected Photovoltaic Generation System)

  • 정진범;신동현;김희준
    • 전기학회논문지
    • /
    • 제57권1호
    • /
    • pp.58-64
    • /
    • 2008
  • In this paper, we present an active anti-islanding method with a load monitoring system using reactive power control. The proposed method, which is based on reactive power control, has fewer harmonics components than those in conventional methods, and it can minimize the reactive power component of the grid because it compensates the reactive power component with the load monitoring. The proposed quick islanding detection method was confirmed from the experimental results with an inverter for a 3kW photovoltaic system.

승강기의 비상 통화장치용 비상 전원장치의 충·방전 제어회로 (Control Scheme of Emergency Power Supply for Elevator Emergency Call System)

  • 박노식;이동희
    • 조명전기설비학회논문지
    • /
    • 제29권8호
    • /
    • pp.40-48
    • /
    • 2015
  • In this paper, battery charging and discharging circuit with a single voltage power supply is proposed. The proposed circuit has the separated current path and charging-monitoring sequence control scheme. In the charging sequence, the proposed 2-level comparator combined with control signal of the micro-processor can control the constant charging current to protect the over current of the battery. Furthermore, the proposed circuit uses a periodic main power switch control to detect the discharging characteristics to estimate the approximated battery life-time. In the experiments, the proposed emergency power supply for emergency call system has 89% efficiency with 98% power factor. And the proposed sequence control scheme is well operated in the designed emergency power system.

화력 발전소의 기동 시퀀스 진행 모니터링을 위한 자료구조 개발 (Development of a Data Structure for Effective Monitoring of Power Plant Start-up Sequences)

  • 이승철;한승우;김승진
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.224-232
    • /
    • 2009
  • 화력발전소를 기동하기 위해서는 수많은 기기조작들이 수동 및 자동으로 또한 순차적 및 병렬로 정확하게 진행되어야 한다. 따라서 발전소의 기동 중 긴박하게 이루어지는 수많은 기기 조작들이 모두 제대로 진행되고 있는지의 여부를 실시간으로 감시하는 일은 매우 복잡하고 긴장을 요하는 임무(task)이다. 본 논문에서는 화력 발전소의 기동시퀀스의 정상 진행 여부를 효과적으로 감시하기 위하여 Event Sequence Monitoring Graph(ESMG)라는 자료구조(Data Structure)를 제안하고 그 구현 기법에 대하여 논하고자 한다. 제안하된 ESMG는 용량 500MW 급의 국내 전형적인 표준형 화력발전소의 주 급수펌프 시스템의 기동 시퀀스의 진행 감시에 적용하기 위한 예를 들었으며 향후 유용하게 활용될 수 있는 가능성을 보였다.

전계결합 무선전력전송의 수신부 감지 방법 (A Novel Receiver Sensing Scheme for Capacitive Power Transfer System)

  • 정채호;임휘열;최성진
    • 전력전자학회논문지
    • /
    • 제24권1호
    • /
    • pp.62-65
    • /
    • 2019
  • Wireless power transfer systems require an algorithm to determine the presence of the target object for mitigating standby power and safety issues. Although many schemes that sense various external objects have been actively proposed for inductive power transfer systems, not many studies on capacitive power transfer systems have been conducted compared with those on inductive power transfer systems. This study proposes a target object detection algorithm by monitoring the capacitance in transmitter-side electrodes without additional pressure sensors or distance sensors. The proposed algorithm determines the presence of a target object by monitoring the change in capacitance in transmitter-side electrodes using the step pulse of the microcontroller unit. The algorithm is verified by two step processes. First, the performance in capacitance measurement is compared with that of an LCR meter. Then, the verification is conducted in a 5-W capacitive power transfer hardware. Experimental result shows that the interelectrode capacitance increases by 6 times when the target object is fully aligned. Thus, the proposed scheme can successfully detect the presence of the target object.

A low cost miniature PZT amplifier for wireless active structural health monitoring

  • Olmi, Claudio;Song, Gangbing;Shieh, Leang-San;Mo, Yi-Lung
    • Smart Structures and Systems
    • /
    • 제7권5호
    • /
    • pp.365-378
    • /
    • 2011
  • Piezo-based active structural health monitoring (SHM) requires amplifiers specifically designed for capacitive loads. Moreover, with the increase in number of applications of wireless SHM systems, energy efficiency and cost reduction for this type of amplifiers is becoming a requirement. General lab grade amplifiers are big and costly, and not built for outdoor environments. Although some piezoceramic power amplifiers are available in the market, none of them are specifically targeting the wireless constraints and low power requirements. In this paper, a piezoceramic transducer amplifier for wireless active SHM systems has been designed. Power requirements are met by two digital On/Off switches that set the amplifier in a standby state when not in use. It provides a stable ${\pm}180$ Volts output with a bandwidth of 7k Hz using a single 12 V battery. Additionally, both voltage and current outputs are provided for feedback control, impedance check, or actuator damage verification. Vibration control tests of an aluminum beam were conducted in the University of Houston lab, while wireless active SHM tests of a wind turbine blade were performed in the Harbin Institute of Technology wind tunnel. The results showed that the developed amplifier provided equivalent results to commercial solutions in suppressing structural vibrations, and that it allows researchers to perform active wireless SHM on moving objects with no power wires from the grid.

FPGA application for wireless monitoring in power plant

  • Kumar, Adesh;Bansal, Kamal;Kumar, Deepak;Devrari, Aakanksha;Kumar, Roushan;Mani, Prashant
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1167-1175
    • /
    • 2021
  • The process of automation and monitoring in industrial control system involves the use of many types of sensors. A programmable logic controller plays an important role in the automation of the different processes in the power plant system. The major control units are boiler for temperature and pressure, turbine for speed of motor, generator for voltage, conveyer belt for fuel. The power plant units are controlled using microcontrollers and PLCs, but FPGA can be the feasible solution. The paper focused on the design and simulation of hardware chip to monitor boiler, turbine, generator and conveyer belt. The hardware chip of the plant is designed in Xilinx Vivado Simulator 17.4 software using VHDL programming. The methodology includes VHDL code design, simulation, verification and testing on Virtex-5 FPGA hardware. The system has four independent buzzers used to indicate the status of the boiler, generator, turbine motor and conveyer belt in on/off conditions respectively. The GSM is used to display corresponding message on the mobile to know the status of the device in on/off condition. The system is very much helpful for the industries working on plant automation with FPGA hardware integration.

Hybrid Communication Network Architectures for Monitoring Large-Scale Wind Turbine

  • Ahmed, Mohamed A.;Kim, Young-Chon
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1626-1636
    • /
    • 2013
  • Nowadays, a rapid development in wind power technologies is occurring compared with other renewable energies. This advance in technology has facilitated a new generation of wind turbines with larger capacity and higher efficiency. As the height of the turbines and the distance between turbines increases, the monitoring and control of this new generation wind turbines presents new challenges. This paper presents the architectural design, simulation, and evaluation of hybrid communication networks for a large-scale wind turbine (WT). The communication network of WT is designed based on logical node (LN) concepts of the IEC 61400-25 standard. The proposed hybrid network architectures are modeled and evaluated by OPNET. We also investigate network performance using three different technologies: Ethernet-based, WiFi-based, and ZigBee-based. Our network model is validated by analyzing the simulation results. This work contributes to the design of a reliable communication network for monitoring and controlling a wind power farms (WPF).

신교통 차량 추진용 리니어모터의 운전성능측정 및 모니터링시스템 구축 (The Monitoring system for the measurement of the operating performance of a LIM which can be drive a new vehicle)

  • 장석명;박영태;서진호;정상섭;이성호;함상용;박찬일;정락교;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 A
    • /
    • pp.74-76
    • /
    • 1997
  • This paper describes the implementation for electrical quanties and mechanical quanties monitoring system of the LIM driven by a inverter. The monitoring system can be display the characteristics of it's quanties, such as voltage, current, power, power factor, frequency, apparent power, thrust, speed, position, normal force, on the real time.

  • PDF