DOI QR코드

DOI QR Code

Development of Moving and Attaching Diagnosis Device Using IoT

IoT 활용 이동착탈식 열화 진단 장치 개발

  • Ka, Chool-Hyun (Department of Electrical Engineering, Shinsung University) ;
  • Lee, Dong-Gyu (Juam Electric & Communication Co. Ltd, Research Center) ;
  • Kim, Jin-Sa (Department of Mechatronics, Chosun College of Science & Technology)
  • 가출현 (신성대학교 전기공학과) ;
  • 이동규 ((주)주암전기통신 기술연구소) ;
  • 김진사 (조선이공대학교 메카트로닉스과)
  • Received : 2017.07.19
  • Accepted : 2017.07.27
  • Published : 2017.09.01

Abstract

The advancement and diversification of urban functions has caused an increasing need to improve the reliability of power supplies. The diversification of urban areas causes social disruptions by paralyzing urban functions during power outages. A large power outage occurs in the event of an accident, owing to the subduction of distribution lines. Therefore, in recent years, for the sake of the environment and safety, the safety diagnosis of electric power facilities has become an important issue. In this system, because thermal information changes rapidly during unattended monitoring owing to heat concentration phenomenon due to abnormal load or deterioration, studies have been conducted on the development of a device that can notify the manager at all times.

Keywords

References

  1. S. T. Heo, Master Thesis, A Study on the Urban Railway System Diagnostics using the Inernet of Things(IoT), p. 1, Seoul National University of Science and Technology, Seoul (2016).
  2. B. K. Seo, Doctorate Thesis, Study on Building of IoT Based Remote Monitoring for Improvement of Fire Protection System Management - Development of Remote Monitoring Model using Alarm Signal Standard Equipment -, p. 5, University of Seoul, Seoul (2017).
  3. J. Yoon, Master Thesis, A Study of Performance Analysis of Firefighting System using IOT Technology, p. 1, University of Seoul, Seoul (2016).
  4. H. N. Ryu, Master Thesis, (A) Study on Secure System for Preventing and Extinguishing Fires on Electric Instruments in House, p. 1, Seoul National University of Science and Technology, Seoul (2016).
  5. J. H. Kim, Master Thesis, Analysis on Aging Characteristics of Insulation used in Oil-filled Transformers and Correlation between the Results using Linear Regression Method, p. 2, Chungnam National University, Daejeon (2010).
  6. H. S. Song and S. D. Lee, J. Korean Inst. IIIum. Electr. Install. Eng., 17, 37 (2003). [DOI: https://doi.org/10.5207/JIEIE.2003.17.1.037]
  7. B. S. Park, J. S. Lim, S. Y. So, J. Lee, I. K. Song, and J. B. Lee, J. Korean Inst. Electr. Electron. Mater. Eng., 20, 183 (2007). [DOI: https://doi.org/10.4313/JKEM.2007.20.2.183]
  8. K. Dodtert, Sens. Actuators, 3, 159 (1983). [DOI: https://doi.org/10.1016/0250-6874(82)80017-6]
  9. J. E. Traister and T. Kennedy, Low Voltage Wiring: Security/Fire Alarm Systems (McGrow Hill, New York, United States, 2001). p. 199-212.
  10. Microelectronic Integrated System, MLX90620 Datasheet, p. 8 (2012).