• 제목/요약/키워드: Electrical and electronic equipments

검색결과 192건 처리시간 0.027초

A Study on the Electrical Strength of Insulating Materials for High-Tc Superconducting Devices

  • Bae, Duck Kweon;Kim, Chung-Hyeok;Pak, Min-Sun;Oh, Yong-Cheul;Kim, Jin-Sa;Shin, Cheol-Gee;Lee, Joon-Ung;Song, Min-Jong;Choi, Woon-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제6권6호
    • /
    • pp.294-300
    • /
    • 2005
  • According to the trend for electric power equipment of high capacity and reduction of its size, the needs for the new high performance electric equipments become more and more important. On of the possible solution is high temperature superconducting (HTS) power application. Following the successful development of practical HTS wires, there have been renewed activities in developing superconducting power equipment. HTS equipments have to be operated in a coolant such as liquid nitrogen ($LN_2$) or cooled by conduction-cooling method such as using Gifford-McMahon (G-M) cryocooler to maintain the temperature below critical level. In this paper, the dielectric strength of some insulating materials, such as unfilled epoxy, filled epoxy, and polyimide in $LN_2$ was analyzed. Epoxy is a good insulating material but fragile at cryogenic temperature. The filled epoxy composite not only compensates for this fragile property but enhances its dielectric strength.

개선된 EMI Filter 설계 및 제작 (Design of Improved EMI Filter)

  • 배대환;구동우;김동일;송재만
    • 한국정보통신학회논문지
    • /
    • 제5권4호
    • /
    • pp.798-806
    • /
    • 2001
  • 전자산업 및 전파통신기술의 급속한 발달에 따라 전기, 전자장치의 경량화, 소형화, 저전력화와 더불어 이들은 인위적인 제어가 어려운 자연 현상에 의한 미소한 전자파장해에도 민감하게 감응하여 오동작을 일으키는 사례가 늘고 있다. 본 논문에서는 이에 대한 개선책의 하나로 기존의 EMI 필터보다 150 kHz~30 GHz 대역에서 10 dB~20 dB 감쇠 효과를 더 가지는 개선된 EMI 필터를 설계 제작하여 전자파 노이즈가 내부 또는 외부로 유출.입 되는 것을 방지하고 부하 변동에 따라 특성의 변화가 없는 EMI 필터로 설계 제작하였다.

  • PDF

전기화재에 따른 진공차단기의 건전성 평가 (A Study on the Evaluation of Reliability of the Vacuum Circuit Breaker for the Electrical Fire)

  • 최홍규;박준열
    • 조명전기설비학회논문지
    • /
    • 제27권7호
    • /
    • pp.24-28
    • /
    • 2013
  • Fire-hited electrical equipment has possibility of deterioration. So its replacement is essential in terms of safety. However, the economic burden is increased. Therefore, the replacement or re-use of it is to be determined by tests. But the research of Integrity Assessment on Fire-hited electrical equipments is very rare. In this paper, we tested to determine the replacement or re-use of Fire-hited vacuum circuit breaker. And provided the data for the integrity assessment through the analysis of its deterioration.

Interfacial Effects in Filled and Reinforced Polymeric Composites

  • Xie, Hengkun
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제11권10호
    • /
    • pp.24-31
    • /
    • 1998
  • Interfacial effect in polymetric composites have been studied extensively. This report deals mainly with the effects of interfacial space charge and interface structure. A model for the dynamic process of interfacial space charge accumulation is proposed. The new model might interpret some interface phenomena which is difficult to be explained in terms of traditional Maxwell-Wagner theory. An interface structure is also presented, by which the importance of surface treatment of glass Fiber for improving the properties of FRP could be well understood.

  • PDF

제어 신호를 이용한 고속철도 전장품의 특성 및 고장 분석 (Characteristics and Fault Analysis of Electric Devices for High-Speed Railway using Control Signal)

  • 한영재
    • 한국전기전자재료학회논문지
    • /
    • 제19권12호
    • /
    • pp.1128-1133
    • /
    • 2006
  • The most important thing to secure safety and reliability of railway vehicles is to verify performance characteristics of equipments, and related companies or research institutes had many efforts to verify performances and functions of equipments synthetically and efficiently. KHST(Korean High Speed Train) has been developed by KRRI (Korea Railroad Research Institute). An electric railway system is composed of high-tech subsystems, among which main electric equipment such as transformers and converter are critical components determining the performance of rolling stock. We developed a measurement system for on-line test and evaluation of performances of KHST. The measurement system is composed of software part and hardware part. Perfect interface between multi-users is possible. A new method to measure temperature was applied to the ]measurement system. By using the system, fault diagnosis and performance evaluation of electric equipment in Korean High Speed Train was conducted during test running.

SMD Inductor Core의 전기적 특성 (The Characteristics of SMD Inductor Core)

  • 오용철;김진사;이동규;신철기;김기준;이철환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.85-88
    • /
    • 2005
  • In this study, it analysis electric field of SMD(Surface Mounted Device) Inductor Core and it get electric field only exist inside of SMD core. Therefore electric fields do not affect any device and equipments. These results are very important to design data acquisition system(several test equipments such as temperature, impedance, and current test), because data acquisition system can place under the SND Inductor core. So, it can be decrease their test error due to electric field.

  • PDF

적외선 열화상 카메라를 이용한 수전설비 온도분포해석 (The Analysis of Temperature Distribution Electric incoming Apparatus Using a Infrared Thermal Imaging System)

  • 정승천;임용배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1113-1116
    • /
    • 2004
  • This paper presents the method for analyzing surface temperature of Electric incoming Apparatus. For the experiment, the surface temperature of electric power apparatus was measured and analyzed by using a infrared thermal imaging system. Surface Discharges(SD) have very complex characteristics of discharge patterns, therefore it requires the development of precise analysis methods. recently, studies on infrared thermal imaging system are carried out to analyze temperature distribution of power equipments through condition diagnosis and to diagnose the degradation of power equipments. The changes in suface temperature was measured by using the infrared thermal imaging system under hot line condition. The system was set up based on the diagnostic method of the electric incoming apparatus.

  • PDF

A Web-based Virtual Laboratory System for Electronic and Digital Circuit Experiments Uing Multimedia

  • Kim, Dong-Sik;Lee, Sun-Heum;Choi, Kwan-Sun;Seo, Sam-Jun;Yoo, Ji-Yoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1178-1182
    • /
    • 2004
  • This paper presents web-based virtual laboratory system for electronic and digital circuit experiments. Through our virtual laboratory, the learners will be capable of learning the concepts and theories related to circuit experiments and how to operate virtual experimental equipments such as multimeters, function generators, digital oscilloscopes, DC power suppliers and bread board etc. The proposed virtual laboratory system is composed of important components: Principle Classroom to explain the concepts and theories of electronic and digital circuit operations, Simulation Classroom to provide a web-based simulator to the learners, Virtual Experiment Classroom to provide interactive multimedia contents about the syllabus of off-line laboratory class, Assessment Classroom, and Management System. With the aid of the management System every classroom is organically tied together collaboration to achieve maximum learning efficiency. We have obtained several affirmative effects such as high learning standard, reducing the total experimental hours and the damage rate for experimental equipments.

  • PDF

액체질소중에 있어서 아크방전 및 방사 전자파의 특성에 관한 연구 (A study on the characteristics of arc discharge and radiated electromagnetic wave in liquid nitrogen)

  • 신동화;박광서;주재현;최병주;김기채;이광식;이동인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1669-1671
    • /
    • 1997
  • Liquid nitrogen has many adventages. It is cheaper than other cooling medium. It is easy to obtain high purity. It's utilized with easy. In future, liquid nitrogen is able to be accepted cooling medium for the superconducting and cryogenic applicated equipments. Cryogenic liquid may be atmospheric pressure state because thermoinsulation is ineffective, airtight decreasing by long time using and bubble occured by flowing current. If it is to be atmospheric pressure state, the electrical insulation strength is dropped and processed partial discharge, finally breakdown. Processing of breakdown has anticipated by measuring radiated-electromagnetic wave which is happened in time of breakdown. There is a measurement of radiated electromagnetic wave as a method that proceeding breakdown is anticipated. In this paper, radiated electromagnetic wave was measured in arc discharge by above conditions as a basic experiment.

  • PDF

가옥내 침입 뇌서지 억제방안 검토 (Study on The Suppression Method for Lightning Surge invaded into House)

  • 이석우;황규현;서호준;이동희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.43-45
    • /
    • 2004
  • Damages of lightning surge for low voltage equipments in the house are increasing due to electronic equipments working in more and more low voltage and becoming smaller. And that is increasing due to increase communication networks in the information-oriented society. So, to achieve effective method of surge protection, there are needs for correlation between indoor wire and propagation aspect of lightning surge. Therefore this paper describes as a result of experiments for propagation aspect of lightning surge according to arrangement of indoor wire.

  • PDF