• Title/Summary/Keyword: Electrical Units

Search Result 712, Processing Time 0.031 seconds

The Review on the Integrated Control System for HWIL Simulation (HWIL 시뮬레이션을 위한 통합 제어 시스템 고찰)

  • Kim, Ki-Seung;Kim, Young-Ju;Hong, Jeong-Woon
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2659-2661
    • /
    • 2002
  • The development of guided missile requires complex guidance schemes and hardware units because of high maneuver, delicate and variable missions. In this point of view, simulation systems and facilities which test missile hardwares and softwares are needed. This paper introduces the hardware-in-the loop simulation system and facilities which include the real-time computation systems and 3 Axis FMS(Flight Motion Simulator).

  • PDF

Analysis of Desalinization Effects ofn Gypsum Treatments in Reclaimed Tidelands (석고처리에 의한 간척지토양의 제염효과 분석)

  • 구자웅;최진규;손재권;이기성
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1999.10c
    • /
    • pp.162-168
    • /
    • 1999
  • This study was performed to analyze dealinization effects on gypsum treatments in reclaimed tidelands and to obtain the basci data for developing prediction techniques f desalinization to be applicable in the begining of tideland reclamation. In this study , the reclamation experiments with 4 treatments were conducted through the leachig method, using the samples of silt soil and silt loam soil collected in 5 units of tideland reclamation projects. The electrical conductivity , exchangeable sodium percentage and hydraulic conductivity were analyzed in order to investigate the effects of desalinizatino for reclaiming the tidelands with high salt concentration.

  • PDF

A Development of VME type Plant Controller (VME형 대용량 플랜트 제어기의 개발)

  • Joo, Moon-Gab;Lee, Gi-Beom;Lee, Jin-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2324-2326
    • /
    • 1998
  • Plant controller using VME bus is developed. This controller is a PLC designed to control up to 768 I/O units of POSFA PLC which has been developed already by POSCON. In many programming aspects, it adopts IEC 1131, international standard of PLC programming to keep up with international trends. A system software and a controller architecture including CPU board, DSP board and bus extension board are developed to support the IEC 1131, and becomes a base of E.I. controller being developed now.

  • PDF

Binary Mask Estimation using Training-based SNR Estimation for Improving Speech Intelligibility (음성 명료도 향상을 위한 학습 기반의 신호 대 잡음 비 추정을 이용한 이산 마스크 추정 방법)

  • Kim, Gibak
    • Journal of Broadcast Engineering
    • /
    • v.17 no.6
    • /
    • pp.1061-1068
    • /
    • 2012
  • This paper deals with a noise reduction algorithm which uses the binary masking approach in the time-frequency domain to improve speech intelligibility. In the binary masking approach, the noise-corrupted speech is decomposed into time-frequency units. Noise-dominant time-frequency units are removed by setting the corresponding binary masks as "0"s and target-dominant units are retained untouched by assigning mask "1"s. We propose a binary mask estimation by comparing the local signal-to-noise ratio (SNR) to a threshold. The local SNR is estimated by a training-based approach. An optimal threshold is proposed, which is obtained from observing the distribution of the training database. The proposed method is evaluated by normal-hearing subjects and the intelligibility scores are computed by counting the number of words correctly recognized.

Characteristics of a Hybrid-type SFCL with Serial and Parallel Connection of Secondary Circuit (2차회로의 직.병렬연결에 따른 하이브리드형 초전도 한류기의 특성)

  • Cho, Yong-Sun;Park, Hyoung-Min;Nam, Goung-Hyun;Lee, Na-Young;Han, Tae-Hee;Choi, Choi-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.393-395
    • /
    • 2006
  • We investigated the operational characteristics of the hybrid-type superconducting fault current limiter (SFCL) according to the serial and parallel connections of secondary circuits. The hybrid-type SFCL consists of a transformer, which has a primary winding and several secondary windings with $YBa_2Cu_3O_7$ films connected in series and parallel. In order to increase the capacity of the SFCL, the serial connection between each current limiting unit is necessary. The hybrid-type SFCL with the serial connection in secondary circuits could show superior characteristics than those of the parallel connections in the current limiting and quench time. The resistances generated in the superconducting units were also lowered at the parallel connections. We confirmed that the parallel connection reduced the power burden of each superconducting unit under the same conditions because of the simultaneous quenching between superconducting units.

  • PDF

Development of a Digital System for Protection and Control of a Substation Part 1 - Development of hardware (변전소의 보호.제어를 위한 디지탈 시스템 개발 PART 1 - 하드웨어 개발)

  • Kwon, W.H.;Lee, Y.I.;Park, H.K.;Park, S.H.;Kim, M.J.;Moon, Y.S.;Yoon, M.C.;Kim, I.D.;Lee, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.359-361
    • /
    • 1992
  • This paper describes the development of an Integrated Digital Protection And Control System (IDPACS) for 345 KV substation. The developed IDPACS system containes digital protection units for transmission lines, delivery lines, transformers, bus, shunt reactors and Shunt capacitors. We deloped a Local Area Network (LAN) Which connects the digital protection units to the station computer for monitoring and control purposes.

  • PDF

Risk Factors for Nosocomial Urinary Tract Infection in the Intensive Care Unit with a Positive Urine Culture and Foley Catheterization (소변 미생물 균주 양성인 중환자실 유치도뇨관 환자의 병원성 요로감염 발생과 관련요인)

  • Yu, Seong-Mi;Park, Kyung-Yeon
    • Journal of Korean Academy of Nursing
    • /
    • v.37 no.7
    • /
    • pp.1149-1158
    • /
    • 2007
  • Purpose: The purpose of this study was to identify the risk factors for a nosocomial urinary tract infection in intensive care units with a foley catheterization which showed a positive urine culture. Method: Three-hundred eighty-seven patients were included in the study. A retrospective review of the electrical medical record system's databases and medical record sheets in hospitalized patients from January 2003 to December 2003 was used. The collected data was analyzed by descriptive statistics, t-test, chi-square test and logistic regression analysis. Result: The frequency of the participants' nosocomial urinary tract infection was 72.9%. Significant risk factors for a nosocomial urinary tract infection were 'age', 'place of catheter insertion', 'frequency of catheter change', and 'duration of catheterization'. These variables explained 18.4% of variance in the experience of nosocomial urinary tract infection in intensive care units with foley catheterization. Conclusion: Medical personnel can decrease the incidence of a nosocomial urinary tract infection by recognizing and paying attention to the duration of catheterization, frequency of catheter change, and place of catheter insertion. As a result, specific and scrupulous strategies should be developed to reflect these factors for decreasing nosocomial urinary tract infections.

Dynamic Simulation of Pump-Storage Power Plants with different variable speed configurations using the Simsen Tool

  • Kruger, Klaus;Koutnik, Jiri
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.4
    • /
    • pp.334-345
    • /
    • 2009
  • Pumped storage power plants are playing a significant role in the contribution to the stabilization of an electrical grid, above all by stable operation and fast reaction to sudden load respectively frequency changes. Optimized efficiency and smooth running characteristics both in pump and turbine operation, improved stability for synchronization in turbine mode, load control in pump mode operation and also short reaction times may be achieved using adjustable speed power units. Such variable speed power plants are applicable for high variations of head (e.g. important for low head pump-turbine projects). Due to the rapid development of power semiconductors and frequency converter technology, feasible solutions can be provided even for large hydro power units. Suitable control strategies as well as clear design criteria contribute significantly to the optimal usage of the pump turbine and motor-generators. The SIMSEN tool for dynamic simulations has been used for comparative investigations of different configurations regarding the power converter topology, types of semiconductors and types of motor-generators including the coupling to the hydraulic system. A brief overview of the advantages & disadvantages of the different solutions can also be found in this paper. Using this approach, a customized solution minimizing cost and exploiting the maximum usage of the pump-turbine unit can be developed in the planning stage of new and modernization pump storage projects.

Operation Characteristic and Harmonic Analysis of 200-MW Modulator (200-MW 모듈레이터의 동작 특성 및 고조파 해석)

  • Park, S.S.;Oh, J.S.;Cho, M.H.;NamKumg, W.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1577-1579
    • /
    • 1994
  • 200-MW pulse modulators(total 11units) for the PLS linac employ the SCR phase control circuit. It controls 3-phase AC line voltage for the high-voltage DC power supply (DCPS, maximum of 25kVDC, 4.2A) which charges the pulse forming network(PFN). The PFN delivers 400kV, 500A, ESW $7.5{\mu}s$ pulse power to the 80-MW klystron amplifier tube. The SCR regulates 3-phase AC power and feeds to the high voltage transformer. Two different types of the transformer configurations namely ${\Delta}-{\Delta}$ and ${\Delta}-Y$, are alternatively installed to 11 modulator units for the suppression of harmonic noises. RC filters and reactors are also installed. Currently, approximately 110-kW of average AC power per unit is consumed at the normal operation level of the modulator with 30pps. This paper presents the operational characteristics of the high power pulse modulator, especially the experimental results of the AC line harmonic components generated by the operation of the high power pulse modulator to suppress the switching noises from the SCR and rectifying diode arrays.

  • PDF

Quench Characteristics of Resistive SFCL Elements in series (직렬 연결된 초전도 한류기의 퀜치 및 한류 특성)

  • Hyun, Ok-Bae;Choi, Hyo-Sang;Kim, Hye-Rim;Lim, Hae-Ryong;Kim, In-Seon
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.663-665
    • /
    • 2000
  • We fabricated resistive superconducting fault current limiters (SFCL) based on YBCO thin films grown on 2-inch diameter saphire substrates Two SFCLs with nearly identical properties were connected in series to investigate the simultaneous quench. There was a slight difference in the rate of voltage increase between two SFCL units when they were operated independently. This difference. however, resulted in significantly unbalanced power dissipation between the units. This imbalance was removed by connecting a shunt resistor to an SFCL in parallel. The appropriate values of the shunt resistances were $80{\Omega}$ at $75 V_{rms}$. $100{\Omega}$ at $100 V_{rms}$ and $110{\Omega}$ at $120 V_{rms}$, respectively. Increased power input at high voltages also reduced the initial imbalance in power dissipation. but with increase in film temperature to higher than 200 K.

  • PDF