• Title/Summary/Keyword: Electrical Units

Search Result 712, Processing Time 0.03 seconds

Function Merger Algorithm for Economic Dispatch (병합연료비함수를 이용한 경제급전 알고리즘 개발)

  • Min, Kyung-Il;Ha, Sang-Hyeon;Lee, Su-Won;Moon, Young-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.115-117
    • /
    • 2007
  • This paper presents a new systematic approach to find a global solution to economic dispatch (ED) with multiple fuel units using a function merger (FM). Currently, no systematic approach has been developed to find a global solution to economic dispatch with multiple fuel units. Various heuristic methods have been proposed, however it is almost impossible to guarantee a global solution by those methods yet. The proposed method uses the FM and $\lambda$-P functions. A FM merges several fuel cost functions into one that satisfies the optimal conditions of an ED. The FM procedures are described in detail with illustrative examples.

  • PDF

A Study on Developement of Optimization Model for Single Action Tidal Power Station (단류식 창조발전의 조력발전소 최적화 운영 Model 개발에 관한 연구)

  • Kim, Hyun-Han;Kim, Man-Kie;Kim, June-Kyou;Ok, Yeon-Ho;Kim, Kwang-Ho;Jeong, Jong-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1144_1145
    • /
    • 2009
  • Tidal power station is using the difference of the ebb and flow and the single action tidal power is dependent on tide amplitude and basin volume. Therefore the inflow of basin in rainy season has also effect on the daily power. Also if operating units are changed then starting head too changed. Therefore the number of units are very important for the optimization model. According to our study the primary point when we make a determination of optimization is starting head and governorl control mode. On this study optimization model for tidal power station is considered all of this conditions.

  • PDF

A study on the Algorithm for the Economic Dispatch of Thermal Units Considering Dynamic Characteristics of Load (부하의 동특성을 고려한 화력발전기의 경제부하배분 앨고리즘에 관한 연구)

  • Song, Kil-Yeong;Park, Kyeng-Soo;Choi, Jae-Suck;Park, Hyun-Sin
    • Proceedings of the KIEE Conference
    • /
    • 1988.11a
    • /
    • pp.92-94
    • /
    • 1988
  • One of the recurring problems facing energy control center dispatchers each day is how to operate the system during the periods of high load pick up and fluctuation. This method reduces the problem to a forward - revised by backward - sequence of dispatch problem, with the generator Limits being carefully adjusted between each time interval in the total intervals to be optimized. It is applied to system of 31 units. It is observed that the method presented here achieves that generation fellows the load changes without any mismatch.

  • PDF

Optimal Placement of Synchronized Phasor Measurement Units for the Robust Calculation of Power System State Vectors (견실한 전력계통 상태벡터 계산을 위한 동기 페이저 측정기 최적배치)

  • Cho, Ki-Seon;Shin, Joong-Rin
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.75-79
    • /
    • 2000
  • This paper proposes the optimal placement with minimum set of Phasor Measurement Units (PMU's) using tabu search and makes an alternative plan to secure the robustness of the network with PMU's. The optimal PMU Placement (OPP) problem is generally expressed as a combinatorial optimization problem subjected to the observability constraints. Thus, it is necessary to make a use of an efficient method in solving the OPP problem. In this paper, a tabu search based approach to solve efficiently this OPP problem proposed. The observability of the network with PMU's is fragile at any single PMU contingency. To overcome the fragility, an alternative scheme that makes efficient use of the existing measurement system in power system state estimation proposed. The performance of the proposed approach and the alternative scheme is evaluated with IEEE sample systems.

  • PDF

Small Nuclear Units and Distributed Resource Prospects(1) (Small Nuclear Units에 의한 분산전원으로서의 전망(1))

  • Lee, Sang-Seung
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.223-225
    • /
    • 2005
  • This paper will be introduce a new paradigm and prospects for energy supply system in near future which produces electric and district heat cogeneration with dispersed power grid with small nuclear power units. Recently, in nuclear field, a lot of effort has been done in nuclear major countries to develop small and medium reactor for enhancement of nuclear peaceful use as like in district heating, electric power generation, seawater desalination or hydrogen generation. This paper presents a new way and prospects for power source in distribution system by using the distributed & remote cogeneration system using small reactor.

  • PDF

Development of Generator Maintenance Scheduling Program (발전기 예방정비계획 전산모형 개발)

  • Park, Jong-Bae;Jeong, Yun-Won;Joo, Haeng-Ro;Yi, Myoung-Hee;Shin, Jum-Gu
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.216-217
    • /
    • 2006
  • This paper presents development of program for generator maintenance scheduling. The maintenance scheduling of generating units is a dynamic discrete combinatorial optimization problem with constraints to determine the optimal maintenance periods of each generating units for a given planning periods. The developed program is designed so as to provide the maintenance schedule satisfying the operating reserve margin levelization and the procurement of proper reliability. In order to verify the effectiveness of the developed program, the numerical study has been performed with the practical data in 2005.

  • PDF

The construction of a PLC simulator for level control (유량 제어을 위한 PLC 시뮬레이터 구성)

  • Lee, Gi-Bum;Yoon, Woo-Sik;Jeong, Hee-Don;Lee, Jin-S.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2605-2607
    • /
    • 2000
  • This paper represents the construction of a PLC simulator for the level control of water and the speed control of the water cask. The level and speed processes are automatically operated by the PLC. The simulator system consists of PLC, program loader and control penal. The digital input and output units make the valves of the water cask the On or Off state. The analog input and output units control the level of water and the speed of the water cask. A LD program is used in the control language of PLC.

  • PDF

Power Generation Unit Modelling in Thermal Power Plant (서천화력 발전기 및 제어시스템 모델링)

  • Kim, Yong-Hak;Kim, Tae-Kyun;Choo, Jin-Bu;Joo, Joon-Young;Song, Seok-Ha
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.15-18
    • /
    • 2003
  • This paper provides the procedure to derive model parameters from the field tests. Since the accuracy of power system analysis depends on the accuracy of models used to represent the generation units, the reliability of power system analysis could be affected by parameters used in those models. The objective of this paper is to validate and update the models. So the field test had performed for thermal units and adjusting the variables to match with the measured values derived their model parameters. And the model parameters are verified by comparing the variables between models.

  • PDF

Implementation of IQ/IDCT in H.264/AVC Decoder Using GP-GPU (GP-GPU를 이용한 H.264/AVC 디코더의 IQ/IDCT구현)

  • Jeong, Jun-Mo;Lee, Kwang-Yeob
    • Journal of IKEEE
    • /
    • v.14 no.2
    • /
    • pp.76-81
    • /
    • 2010
  • The need for dedicated hardware continue to decrease as the mobile CPU's performance increases. But, there is a limit to a mobile CPU's performance. GP-GPU(General-Purpose computing on Graphics Processing Units) can improve performance without adding other dedicated hardware. This paper presents the implementation of Inverse Quantization, Inverse DCT and Color Space Conversion module in H.264/AVC decoder using GP-GPU for a mobile environments. The proposed architecture improves approximately 40% of performance when it use all the features.

The Functions and Characteristics of Distribution Automation System Components (국산 배전자동화시스템 구성설비의 보유기능 및 특성)

  • Ha, B.N.;Park, S.M.;Jang, J.T.;Choi, T.I.;Kim, H.Y.;Oh, S.G.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.899-901
    • /
    • 1996
  • KODAS is made up of the Central Control System(CCS) as four Vax workstations linked up with LAN networks, six Substation Communication Control Units(SCCU) installed in substation to transfer data, 125 Feeder Remote Units(FRU) located at the lower position of automated switch to provide the information of Fault Indicator(FI) and three kinds of automated switches to have remote control functions such as SF6 gas feeder automation switch, recloser and gas insulated pad mountes switchgear for under ground line. This paper explains the functions and characteristics in detail about each devices mentioned above.

  • PDF