• Title/Summary/Keyword: Electrical Units

Search Result 712, Processing Time 0.028 seconds

Economic Dispatch Problem Using Advanced Genetic Algorithms (개선된 유전 알고리즘을 이용한 경제급전 문제해석)

  • Park, Jong-Nam;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.1106-1108
    • /
    • 1997
  • This paper presents a new approach on genetic algorithms to economic dispatch problem for valve point discontinuities. Proposed approach in this paper on genetic algorithms improves the performance to solve economic dispatch problem for valve point discontinuities through combination in penalty function with death penalty, generation-apart elitism, atavism and heuristic crossover. Numerical results on an actual utility system consisted of 13 thermal units show that the proposed approach is faster and robuster than classical genetic algorithm.

  • PDF

Effects of an Angle Droop Controller on the Performance of Distributed Generation Units with Load Uncertainty and Nonlinearity

  • Niya, M.S. Koupaei;Kargar, Abbas;Derakhshandeh, S.Y.
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.551-560
    • /
    • 2017
  • The present study proposes an angle droop controller for converter interfaced (dispatchable) distributed generation (DG) resources in the islanded mode of operation. Due to the necessity of proper real and reactive power sharing between different types of resources in microgrids and the ability of systems to respond properly to abnormal conditions (sudden load changes, load uncertainty, load current disturbances, transient conditions, etc.), it is necessary to produce appropriate references for all of the mentioned above conditions. The proposed control strategy utilizes a current controller in addition to an angle droop controller in the discrete time domain to generate appropriate responses under transient conditions. Furthermore, to reduce the harmonics caused by switching at converters' output, a LCL filter is used. In addition, a comparison is done on the effects that LCL filters and L filters have on the performance of DG units. The performance of the proposed control strategy is demonstrated for multi islanded grids with various types of loads and conditions through simulation studies in the DigSilent Power Factory software environment.

Parallel Computation of FDTD algorithm using CUDA (CUDA를 이용한 FDTD 알고리즘의 병렬처리)

  • Lee, Ho-Young;Park, Jong-Hyun;Kim, Jun-Seong
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.47 no.4
    • /
    • pp.82-87
    • /
    • 2010
  • Modern GPUs(Graphic Processing Units) provide computing capability higher than that of the general CPUs(Central Processor Units). With supports of programmability of graphics pipeline GP-GPU(General Purpose computation on GPU) has gained much attention expanding its application area. This paper compares sequential and massively parallel implementations of FDTD(Finite Difference Time Domain) algorithm using CUDA(Compute Unified Device Architecture). Experimental results show upto 45X speedup over conventional CPU execution.

White Organic Light-emitting Diodes using the Tandem Structure Incorporating with Organic p/n Junction

  • Lee, Hyun-Koo;Kwon, Do-Sung;Lee, Chang-Hee
    • Journal of Information Display
    • /
    • v.8 no.2
    • /
    • pp.20-24
    • /
    • 2007
  • Efficient white organic light-emitting diodes are fabricated with the blue and red electroluminescent (EL) units electrically connected in a stacked tandem structure by using a transparent doped organic p/n junction. The blue and red EL units consist of the light-emitting layer of 1,4-bis(2,2-diphenyl vinyl)benzene (DPVBi) and 4-dicyanomethylene-2-methyl-6-[2-(2,3,6,7-tetrahydro-1H,5H-benzo[i,j] quinolizin-8-yl)vinyl]-4H-pyran) (DCM2) doped tris(8-hydroxyquinoline) aluminum $(Alq_3)$, respectively. The organic p-n junction consists of ${\alpha}-NPD$ doped with $FeCl_3$ (15 % by weight ratio) and $Alq_3$ doped with Li (10 %). The EL spectra exhibit two peaks at 448 and 606 nm, resulting in white light-emission with the Commission Internationale d'Eclairage (CIE) chromaticity coordinates of (0.36, 0.24). The tandem device shows the quantum efficiency of about 2.2 % at a luminance of 100 $cd/m^2$, higher than individual blue and red EL devices.

An Efficient Block Cipher Implementation on Many-Core Graphics Processing Units

  • Lee, Sang-Pil;Kim, Deok-Ho;Yi, Jae-Young;Ro, Won-Woo
    • Journal of Information Processing Systems
    • /
    • v.8 no.1
    • /
    • pp.159-174
    • /
    • 2012
  • This paper presents a study on a high-performance design for a block cipher algorithm implemented on modern many-core graphics processing units (GPUs). The recent emergence of VLSI technology makes it feasible to fabricate multiple processing cores on a single chip and enables general-purpose computation on a GPU (GPGPU). The GPU strategy offers significant performance improvements for all-purpose computation and can be used to support a broad variety of applications, including cryptography. We have proposed an efficient implementation of the encryption/decryption operations of a block cipher algorithm, SEED, on off-the-shelf NVIDIA many-core graphics processors. In a thorough experiment, we achieved high performance that is capable of supporting a high network speed of up to 9.5 Gbps on an NVIDIA GTX285 system (which has 240 processing cores). Our implementation provides up to 4.75 times higher performance in terms of encoding and decoding throughput as compared to the Intel 8-core system.

Analsis of Preponderant Wear of Earth Brush for an Electrical Multiple Units(EMUs) (전동차용 접지브러쉬 편중마모에 대한 해석)

  • Park, Byung-Sup;Ku, Jung-Su;Kim, Gil-Dong
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.356-361
    • /
    • 2005
  • Earth brush for electrical multiple units(EMUs) is a device through which the current of the EMU load's consumed power fed from the DC 1,500V overhead line (or from the AC 25.000V catenary) flows via axle to the rail(ground) and which prevents the electric corrosion of the axle bearings by preventing the current flow to the axle bearings caused by electric potential from the magnetic field when the bearings rotate together with the earthing function when a thunderbolt falls or a surge comes. The earth brush wear rates among cars, however, shows quite differences when the earth brushes after being separated from the holders are measured with vernier callipers every 6 months of maintenance period. Main causes of the earth brush wear are divided as mechanical, electric arc and electrical one, and the factors can be running speed, current, harmonics, connection state. spring tension, earth brush material, lubricant and so on. but only the earth brushes of the motor(M1) car show the highest wear rate and moreover maintenance difficulty occurs because of the wear rate differences among e earth brushes in one holder. The reason for these preponderant wear comes from the design concept of making preponderant current flow to some particular earth brushes and moreover the heat generated by the harmonics when the inverter starts to operate accelerate the wear. By defining these causes through experiments. I hope that the found results would be helpful for the future EMU design, safety, economy and maintenance.

  • PDF

FPGA application for wireless monitoring in power plant

  • Kumar, Adesh;Bansal, Kamal;Kumar, Deepak;Devrari, Aakanksha;Kumar, Roushan;Mani, Prashant
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1167-1175
    • /
    • 2021
  • The process of automation and monitoring in industrial control system involves the use of many types of sensors. A programmable logic controller plays an important role in the automation of the different processes in the power plant system. The major control units are boiler for temperature and pressure, turbine for speed of motor, generator for voltage, conveyer belt for fuel. The power plant units are controlled using microcontrollers and PLCs, but FPGA can be the feasible solution. The paper focused on the design and simulation of hardware chip to monitor boiler, turbine, generator and conveyer belt. The hardware chip of the plant is designed in Xilinx Vivado Simulator 17.4 software using VHDL programming. The methodology includes VHDL code design, simulation, verification and testing on Virtex-5 FPGA hardware. The system has four independent buzzers used to indicate the status of the boiler, generator, turbine motor and conveyer belt in on/off conditions respectively. The GSM is used to display corresponding message on the mobile to know the status of the device in on/off condition. The system is very much helpful for the industries working on plant automation with FPGA hardware integration.

A Study on the lighting Installation Regulations in Waterpark, Public Bath and Similar Places for the Prevention of Electrical Shock (감전사고 방지를 위한 물놀이.입욕시설의 조명설비 시설규정 연구)

  • Kim, Chong-Min;Kim, Han-Sang;Kim, Gi-Hyun;Hwang, Kwang-Su
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.339-344
    • /
    • 2005
  • A person's body resistance in the waterpark, public bath and similar places is lower than any other places due to effect of water. So low voltage may create a shock hazard for the human body in case of leakage or fault currents from lighting unit etc. We researched the related regulations these are internal standards, NEC, IEC and investigated the actual conditions for the prevention of electrical shock due to lighting units in the waterpark, public bath and similar places. So we could present actual facilities's problems and solutions

  • PDF

System reorganization of electrical standard Production Units and effect analysis of electrical construction business (전기부문 표준품셈 체계개편과 전기공사업계의 영향분석)

  • Lim, S.H.;Hwang, M.S.;Shin, K.S.;Kim, J.I.;Sun, A.S.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2060-2061
    • /
    • 2007
  • 본 논문에서는 국가 경제성장률과 국내 전기공사실적 증가률에 대한 상관관계를 비교분석하였으며, 연간 전기공사 실적에 대한 항목별 구성비율 중 노무비가 차지하는 비율을 분석하였다. "국가를 당사자로 하는 계약에 관한 법률 시행령 및 시행규칙"과 회계예규인 "예정가격 작성기준"에 근거하여 원가계산에 의한 전기공사 예정가격 산정의 기초자료로 활용되는 전기부문 표준품셈 체계개편이 전기공사업에 미치는 영향을 최근 발주된 대형공사에 체계개편 전과 체계개편 후 공사금액을 비교하여 종합적으로 분석하였다.

  • PDF

A New Resource Allocation Algorithm of Functional Units to Minimize Power Dissipation (전력소비 최소화를 위한 새로운 펑션유닛의 자원 할당 알고리듬)

  • Lin, Chi-Ho
    • Journal of IKEEE
    • /
    • v.8 no.2 s.15
    • /
    • pp.181-185
    • /
    • 2004
  • This paper reduces power dissipation with the minimum switching activity of functional units that have many operators. Therefore, it has more effects of power dissipation that operator dissipation to reduce power dissipation of whole circuit preferentially. This paper proposes an algorithm that minimize power dissipation in functional units operations that affect much as power dissipation in VLSI circuit. The algorithm has scheduled operands using power library that has information of all operands. The power library upgrades information of input data in each control step about all inputs of functional units and the information is used at scheduling process. Therefore, the power dissipation is minimized by functional units inputs in optimized data. This paper has applied algorithm that proposed for minimizing power dissipation to functional unit in high level synthesis. The result of experiment has effect of maximum 9.4 % for minimizing power dissipation.

  • PDF