A Study on the selection and noise test of elelctronic sensor for Vacuum Circuit Breaker (진공차단기용 전자식 센서의 선정 및 노이즈 시험에 관한 연구)

  • Lee, Ki Seon;Park, Jung Cheul;Chu, Soon Nam
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.10
    • /
    • pp.2503-2508
    • /
    • 2014
  • This study is about the selection and noise test of electronic sensor which is preceded by electric Operating Cell(EOC) development using electronic sensor technology to solve the structural weakness of Mechanism Operated Cell(MOC) in VCB, and has a final target in product development minimizing contact malfunction of the chattering or rebounce states caused by existing MOC. In this test results, when opening and closing VCB, rising velocity of surge voltage in opening time was measured 4.2 times faster than closing time and noise decibel value was measured respectively 120dB and 110dB. When supplying 60kV power frequency overvoltage, we found that sensor output graph in VCB opening and closing times operated stably without distortion. When supplying 150kV $1.2{\times}50{\mu}s$ impulse frequency voltage, we found that voltage graph of output contact in sensor opening and closing sides maintained a normal condition without distortion, and when supplying 2500A current, we found that tested result of electric field noise operated stably without distortion.

A Development of Intelligent Controller for Phase Control in Main Circuit Breaker (주회로차단기 투입전원 위상제어를 위한 지능형 제어기 개발)

  • Oh, Yong-Kuk;Kim, Jae-Won;Ryu, Joon-Hyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.755-761
    • /
    • 2017
  • In railways powered by AC power, the main circuit breaker (MCB) is used for supplying the electric power to the catenary of the vehicle. Generally, the main circuit breaker is located between the pantograph and the main transformer, and the phase of the power applied to the vehicle changes according to the operation timing of the main circuit breaker. The operation of the main circuit breaker should be actively controlled according to the phase of the power source, since the phase of the power causes unintended transient states in the vehicle's electrical system in the form of an inrush current and surge voltage. However, the MCB has a delay time when it operates which is not constant. Therefore, an intelligent controller is needed to predict the operation delay time and control the opening and closing of the MCB.

Development and Verification of Lightning Induced Transient Protection Device for Avionics Computer (항공기 탑재 컴퓨터용 간접낙뢰 보호장치 개발 및 검증)

  • Sim, Yong-gi;Ahn, Tae-sik;Park, Jun-hyun;Han, Jong-pyo;Yang, Seo-hee
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.5
    • /
    • pp.395-402
    • /
    • 2015
  • This paper introduces the design details and test procedures of the lightning induced transient protection device for protecting the damage caused by indirect lightning strike on the computer mounted on the aircraft. Lightning induced surge voltage is bring a malfunction or damage to the aircraft electrical and electronic equipment, that is referred to indirect effects of lightning. In order to protect the electronic equipment on aircraft from the indirect effects of lightning, that is achieved by analyzing the effect on aircraft from lightning and protect design for each devices. In this paper, we introduce an indirect lightning strike level decisions, the protection circuit design method according to the chosen level through the RTCA DO-160G Section 22 category analysis and selection was performed in order to protect the damage caused by indirect lightning strikes in the protected equipment. In addition, we show the indirect lightning effects verification test performed to validate the designed protection circuits.

The Development of Integrated Power Quality Diagnosis System for Power System (전력계통 전력품질 통합진단시스템 개발)

  • Kwak, N.H.;Jeon, Y.S.;Park, S.H.;Lee, I.M.;Park, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.277-279
    • /
    • 2005
  • Recently, due to the increase of power conversion devices and nonlinear loads with the development of information, communication and control technologies, the instantaneous minute interruption factors such as voltage & current harmonics, surge occurring frequency, instantaneous voltage variation, voltage unbalance, flicker etc. have greatly threatened the power quality, and the deterioration of electric power facilities and the functional error of controllers are increasing. As such an instantaneous minute interruption appears to be small and local, accurate evaluation with measurement is difficult and total analysis system is required through a wide range of power quality effect analysis such as the simultaneous measurement on various power supply phenomena and the analysis on the interrelation with system loads. Most of conventional power quality diagnosis equipments have beer developed and applied, which were able to measure the stability rate of frequency, the stability rate of voltage, the electricity-failure duration etc, However, they were insufficient to analyze the system present situation, understand the cause of the failure occurred by the problem of power quality and analyze out the phenomena. Accordingly, this study will address the development of the system for a wide range of power quality diagnosis over the present level, the system for supporting the determination such as the analysis on risk factors, failure mode and impact, the system for harmonic evaluation based on international standards(IEC 61000 Series) and the total power quality diagnosis network & system with the extension and openness as a local and national-scale broadband power quality diagnosis system.

  • PDF

Detection Technique and Device of Series Arcing Phenomena (직렬아크현상의 검출기술 및 장치)

  • Ji, Hong-Keun;Jung, Kwang-Suk;Park, Dae-Won;Kil, Gyung-Suk;Seo, Dong-Hoan;Rhyu, Keel-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.332-338
    • /
    • 2010
  • Annually, electrical fires caused by arcing phenomena in power system rapidly increase as the use of more electric appliances, but there is no established method for the prevention of the accidents. With this background, this paper dealt with the experimental results on a series arc detection technique and a device for air conditioners. Series arcing phenomena that is generated in incomplete connection of air conditioners was simulated, and the frequency spectrum was analyzed. The Fast Fourier Transform (FFT) of the arc pulse showed that the dominant frequency components exist in ranges of 190 kHz~250 kHz and 900 kHz~1.6 MHz. An arc detection circuit with low cut off frequency of 170 kHz to attenuate 60 Hz by 170 dB and a signal discriminator were designed. Also, an algorithm which separate series arc signal from unwanted noises produced by switching operation, inverter, and surge was proposed. Application experiment was carried out on several types of air-conditioners by using the arc generator specified in UL1699, and the results showed the over 99 % accuracy.

Design and Frequency Characteristic Analysis of Shielded Isolation Transformer for the Power Line Noise Reduction (전원노이즈 억제용 차폐절연변압기의 설계 및 주파수특성 해석)

  • 이재복;허창수;이태호
    • Journal of the Korean Magnetics Society
    • /
    • v.9 no.1
    • /
    • pp.55-63
    • /
    • 1999
  • It is necessary to eliminate the broad band noise whose frequency is in the range of several kHz to tens MHz generated from the AC power line to supply the power to electrical and electronic equipments. Because this kind of noise could damage or malfunction such equipments. To suppress those noises, some conventional devices such as a filter or surge suppressor have been used. However, they can not be isolated from the common-mode noise widely spreaded in all power line, which results in poor common-mode rejection performance. In this paper, we proposed a design method of shielded isolation transformer and a jumped circuit analysis model for shielded isolation transformer applicable to filtering common-mode noise as well as normal-mode noise. The analysis model has been verified as a suitable one for shielded isolation transformer through comparison of the simulation with experiment. In addition, it has been shown that the reduction performance for conducted noise of prototype 3 kVA shielded isolation transformer is superior to a unshielded isolation transformer.

  • PDF

A Study of Korean Efficiency of PV PCS (태양광 인버터의 한국형 전력변환 효율에 관한 연구)

  • Kim, Jeong-Hwan;Yu, Byung-Gyu;So, Jung-Hun;Lee, Ki-OK;Yu, Gwon-Jong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.356-360
    • /
    • 2009
  • Recent global environmental pollution and contamination and depletion of limited fossil energy prices surge as an energy source to replace it depending on wind, fuel cells and solar power and other renewable and pollution free renewable energy is of interest in increase. The photovoltaic systems are pollution-free, unlimited energy source, and easy to install because it is rated as the most valuable renewable energy sector and the prevalence is spreading throughout the world. Photovoltaic systems at one end of the stable development of the role that solar power inverter applications can be the most important. No matter how much power the solar arrays, even if the inverter output in the normally if he's no use. These photovoltaic inverters to evaluate the performance of the inverter efficiency measures that can be called directly. This way of measuring the efficiency of solar inverters in Europe efficiency and CEC efficiency is currently being used. In this paper, until now about how to measure the efficiency of solar power inverter technology and the new Korean Meteorological Solar Insolation data analysis to derive weights based on this inverter efficiency for Korea is to offer.

  • PDF

Automatic On-Chip Glitch-Free Backup Clock Changing Method for MCU Clock Failure Protection in Unsafe I/O Pin Noisy Environment (안전하지 않은 I/O핀 노이즈 환경에서 MCU 클럭 보호를 위한 자동 온칩 글리치 프리 백업 클럭 변환 기법)

  • An, Joonghyun;Youn, Jiae;Cho, Jeonghun;Park, Daejin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.12
    • /
    • pp.99-108
    • /
    • 2015
  • The embedded microcontroller which is operated by the logic gates synchronized on the clock pulse, is gradually used as main controller of mission-critical systems. Severe electrical situations such as high voltage/frequency surge may cause malfunctioning of the clock source. The tolerant system operation is required against the various external electric noise and means the robust design technique is becoming more important issue in system clock failure problems. In this paper, we propose on-chip backup clock change architecture for the automatic clock failure detection. For the this, we adopt the edge detector, noise canceller logic and glitch-free clock changer circuit. The implemented edge detector unit detects the abnormal low-frequency of the clock source and the delay chain circuit of the clock pulse by the noise canceller can cancel out the glitch clock. The externally invalid clock source by detecting the emergency status will be switched to back-up clock source by glitch-free clock changer circuit. The proposed circuits are evaluated by Verilog simulation and the fabricated IC is validated by using test equipment electrical field radiation noise

Configuration of Fuel Cell Power Generation System through Power Conversion Device Design (전력변환장치 설계를 통한 연료전지 발전시스템 구성)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.6
    • /
    • pp.129-134
    • /
    • 2021
  • Recently, the demand for electricity is gradually increasing due to the rapid industrial development and the improvement of living standards. In the case of Korea, which is highly dependent on fossil fuels due to such a surge in electricity demand, reduction and freezing of greenhouse gas emissions due to international environmental regulations will immediately lead to a contraction in industrial activities. Accordingly, there are many difficulties in competition with advanced countries that want to link the environment with the country's industrial production activities, and the development of alternative energy as a countermeasure is of great interest around the world. Among these new power generation methods, small-scale power generation facilities with relatively small capacity include photovoltaic generation, wind power generation, and fuel cell generation. Among them, the fuel cell attracts the most attention in consideration of continuous operation, high power generation efficiency, and long-term durability, which are important factors for practical use. Therefore, in this paper, the fuel cell power generation system was researched and constructed by designing the power conversion circuit necessary to finally obtain the AC power used in our daily life by using the DC power generated from the fuel cell as an input.