Induction Motor Bearing Damage Detection Using Stator Current Monitoring (고정자전류 모니터링에 의한 유도전동기 베어링고장 검출에 관한 연구)

  • Yoon, Chung-Sup;Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.36-45
    • /
    • 2005
  • This paper addresses the application of motor current spectral analysis for the detection of rolling-element bearing damage in induction machines. We set the experimental test bed. They is composed of the normal condition bearing system, the abnormal rolling-element bearing system of 2 type induction motors with shaft deflection system by external force and a hole drilled through the outer race of the shaft end bearing of the four pole test motor. We have developed the embedded distributed fault tolerant and fault diagnosis system for industrial motor. These mechanisms are based on two 32-bit DSPs and each TMS320F2407 DSP module is checking stator current The effects on the stator current spectrum are described and related frequencies are also determined. This is an important result in the formulation of a fault detection scheme that monitors the stator currents. We utilized the FFT(Fast Fourier Transform), Wavelet analysis and averaging signal pattern by inner product tool to analyze stator current components. Especially, the analyzed results by inner product clearly illustrate that the stator signature analysis can be used to identify the presence of a bearing fault.

A Study on the Surge Propagation Property of Underground Distribution Cables by Field Tests (지중배전케이블의 서어지 전파특성 실증연구)

  • Lee, Jae-Bong;Kim, Byung-Sook;Park, Chul-Bae;Jung, Yeon-Ha;Han, Byung-Sung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.118-125
    • /
    • 2007
  • The lightning surge and switching surge could be injected to the underground distribution line through the riser pole in the mixed distribution line of overhead and underground. These surges travel along the cable and are reflected at the end of cable. It can be doubled and affecting underground distribution facilities. It was made a underground distribution model representing KEPCO's distribution system. It was measured propagation characteristics by applying lightning surges to this underground distribution model. Meanwhile, this system was simulated with ATP-EMTP and compared these real test results md tuned up the EMTP parameters. EMTP simulation results showed that accord with real test result by adjusting the cable insulation permitivity, arrester characteristics, surge wave shape.

Application of Neural Network Control Algorithm and Maximum Power Tracking of Sun Photocell using Sunlight Sensor (태앙광 센서에 의한 태앙광 전지의 최대전력추적과 신경회로망 제어알고리즘 적용)

  • Yoo, Seok-Ju;Lee, Seong-Su;Park, Wal-Seo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.2
    • /
    • pp.33-38
    • /
    • 2010
  • Recently, photovoltaic generator system is widely extended by energy policy of the government. Add to this, high efficiency of photocell power generation is steady needed to sun tracking method. However sun tracking method is not widely extended by insufficiency of tracking technology. As method of solving this problem, this paper applied sunlight sensor and neural network control algorithm for maximum power tracking of sun photocell. Sun tracking sensor consists of one upright square pole and form light sensor of east, west, south, north on flat board. Sun tracking dual axes control is operated respectively by two motor. Motor control input is calculated by neural network control algorithm. The function of proposed control method is verified by sun tracking experiment of photocell generation. The sun tracking method of this paper is increased 32[%] efficiency more than fixed method.

Analysis on the Induced Lightning Shielding Effect According to the Neutral Wire Installation Structure of a 22.9kV Distribution Line (22.9kV 배전선로 중성선 설치 구조에 따른 유도뢰 차폐효과 분석)

  • Kim, Jeom-Sik;Kim, Do-Young;Park, Yong-Beom
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.191-196
    • /
    • 2010
  • The electricity distribution system in Korea is adopting a multi-grounding system. Protection of this distribution system against lightning is performed by installing overhead ground wires over the high voltage wires, and connecting the overhead ground wires to the ground every 200 m. The ground resistance in this system is limited not to exceed $50\Omega$ and overhead ground wire and neutral wire are multiple parallel lines. Although overhead ground wire and neutral wire are installed in different locations on the same pole, this circuit configuration has duplicated functions of providing a return path for unbalanced currents and protecting the distribution system against induced lightning. Therefore, the purpose of this study is to analyze the induced lightning shielding effect according to the neutral wire installation structure of a 22.9kV distribution line in order to present a new 22.9kV distribution line structure model and characteristics. This study calculated induced lightning voltage by performing numerical analysis when an overhead ground wire is present in the multi-grounding type 22.9kV distribution line structure, and calculated the induced lightning shielding effect based on this calculated induced lightning voltage. In addition, this study proposed and analyzed an improved distribution line model allowing the use of both overhead wire and neutral wire to be installed in the current distribution lines. The result of MATLAB simulation using the conditions applied by Yokoyama showed almost no difference between the induced lightning voltage developed in the current line and that developed in the proposed line. This signifies that shielding the induced lightning voltage through overhead wire makes no difference between current and proposed distribution line structures. That is, this study found that the ground resistance of the overhead wire had an effect on the induced lightning voltage, and that the induced lightning shielding effect of overhead wire is small.

A Study of the Development of Lighting Equipment on Low Height Road Lighting (낮은 도로조명 방식의 기구디자인 개발연구)

  • Lee, Mi-Ae;Hwang, In-Tae;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.8
    • /
    • pp.1-7
    • /
    • 2009
  • This study is intended to propose the environment friendly lighting which can be excluded the element of obtrusive light(glare, spill light) and to make the sight environment of the external and internal road more comfortable as newly approaching the lower positioned lighting from the current high pole lighting. Taking account of the current situation of putting the stress on the road sight scene. It is proposed the study focused on the aesthetic design for playing a role of scenery. For this, it is searched used situation of the low light at interior of the country and abroad and tried to find the improvement. Also it is tried find out how to raise the effectiveness. And throughout the site inspection and the data searching about the road facility of a road to be installed the low height lighting, it is suggested the standard of the lighting installation and the direction for the future on the light design and development of the low height lighting which is suitable for the domestic situation.

Effect of Deposition Temperature on Structural Properties of ZnO Thin Films on 4H-SiC Substrate (4H-SiC 기판 위에 성장된 ZnO 박막의 온도에 따른 구조적 특성 분석)

  • Kim, Ji-Hong;Cho, Dae-Hyung;Moon, Byung-Moo;Bahng, Wook;Kim, Sang-Cheol;Kim, Nam-Kyun;Koo, Sang-Mo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.120-120
    • /
    • 2008
  • We demonstrate epitaxial growth of ZnO thin films on 4H-SiC(0001) substrates using pulsed laser deposition (PLD). ZnO and SiC have attracted attention for their special material properties as wide band gap semiconductors. Especially, ZnO could be applied to optoelectronic applications such as light emitting devices and photo detectors due to its direct wide bandgap (Eg) of ~3.37eV and large exciton binding energy of ~60meV. SiC shows a good lattice matching to ZnO compared with other commonly used substrates and in this regard SiC is a good candidate as a substrate for ZnO. In this work, ZnO thin films were grown on 4H-SiC(0001) substrates by PLD using an Nd:YAG laser with a 355nm wavelength. The crystalline properties of the films were evaluated by x-ray diffraction (XRD) $\theta-2\theta$, rocking curve and pole figure measurements using a high-resolution diffractometer. The surface morphology of the films was studied by atomic force microscopy (AFM).

  • PDF

Paper-Based Pattern Switchable Antenna Using Inkjet-Printing Technology (잉크젯 프린팅 기술을 이용한 종이 기반의 방사패턴 가변 안테나)

  • Eom, Seung Hyun;Lim, Sungjoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.7
    • /
    • pp.613-619
    • /
    • 2015
  • In this paper, we proposed a paper-based pattern-switchable antenna using inkjet-printing technology. The proposed antenna is composed of two bow-tie antennas and a switching network. The bow-tie antennas are inkjet-printed on paper using a low cost home printer. The switching network is built on a printed-circuit-board(PCB) and consists of a single-pole-double-throw(SPDT) switch and balun element. A double-sided parallel-strip line(DSPSL) can convert the unbalanced microstrip mode to the balanced strip mode. Two bow-tie antennas have different radiation patterns because of the different orientation of the reflectors. It is demonstrated from EM simulation and measurement that the radiation patterns of the proposed antenna are successfully switched by the SPDT.

A Study on Stator Winding Turn-Fault Model for Fault Diagnosis in Inverter-Driven Permanent Magnet Moor Drives (고장진단을 위한 영구자식 동기전동기의 권선 단락에 의한 고장모델 연구 및 특성해석)

  • Kim, Kyeong-Hwa;Choi, Dong-Uk;Gu, Bon-Gwan;Jung, In-Soung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.18-28
    • /
    • 2009
  • To analyze influences under faults caused by a stator winding short and to evaluate an effectiveness of a diagnostic algorithm a faulty model for an inverter-driven permanent magnet synchronous motor is presented. Even though the conventional dq motor model obtained through the transformation of phase voltage model is widely used to analyze and control the motor, it can not be used in the analysis of a faulty motor since the 3-phase balanced condition is no longer hold under the fault caused by a stator winding short, and thus, it is very difficult to obtain motor input voltages from the pole voltage of an inverter. To overcome this problem, a faulty model for an inverter-driven permanent magnet synchronous motor is proposed by considering the line voltage of 3-phase variables. The effectiveness of the proposed faulty model is verified through comparative simulations and experiments using DSP TMS320F28335 and motor built to allow a partial short of inter-turn.

Comparison and Torque Analysis for Magnetic Gear with Parallel/Halbach Magnetized PMs according to Design Parameters (평행방향/할박 자화 영구자석을 갖는 마그네틱 기어의 설계변수에 따른 토크특성 해석 및 비교)

  • Hong, Sang-A;Choi, Jang-Young
    • Journal of the Korean Magnetics Society
    • /
    • v.24 no.5
    • /
    • pp.152-159
    • /
    • 2014
  • Magnetic gear can transmit torque without any mechanical contact among rotational parts in rotating mechanical systems. Especially, magnetic gear using rare-earth PMs can be used in variety of industry application because of their great power efficiency. Thus, recent trend shows that magnetic gear can be replaced with common mechanical gear. This paper deals with comparison and torque analysis for magnetic gears with parallel and Halbach magnetization according to various design parameters. Using a two dimensional (2D) finite element (FE) analysis, suitable gear ratio is selected. We performed analysis for magnetically connected inner and outer torque with respect to various design parameters including thickness of inner and outer PM, steel pole angle, segments of Halbach array and magnetization pattern of inner and outer PMs. Finally, we can obtain improved design model having parallel and Halbach magnetization with larger torque, compared with an initial design model.

A Study on the Application of SVR at the Distribution Line Interconnected with Wind Turbine (풍력발전이 연계된 배전선로의 SVR 적용연구)

  • Chae, Woo-Kyu;Lee, Hak-Ju;Jung, Won-Wook;Kim, Ju-Yong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.109-118
    • /
    • 2010
  • It is expected that distribution system, interconnected with wind turbines, would experience the voltage problem due to WT's output. But most papers just consider this problem using the simulation or the theory only. In this paper, we verify this problem through the measurement at the distribution system and wind turbine. We explain the method for voltage management at distribution system. And we verify that the voltage of D/L interconnected with WTs could not be maintained properly using pole transformer's tap only. We consider some method to solve this problem and we propose the installation of SVR(step voltage regulator). Finally we show this method's validity through the simulation.