• Title/Summary/Keyword: Electrical Isolation

Search Result 617, Processing Time 0.129 seconds

Design Aspects of a New Reliable Torsional Switch with Excellent RF Response

  • Gogna, Rahul;Jha, Mayuri;Gaba, Gurjot Singh;Singh, Paramdeep
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.1
    • /
    • pp.7-12
    • /
    • 2016
  • This paper proposes a metal contact RF MEMS switch which utilizes a see-saw mechanism to acquire a switching action. The switch was built on a quartz substrate and involves vertical deflection of the beam under an applied actuation voltage of 5.46 volts over a signal line. The see-saw mechanism relieves much of the operation voltage required to actuate the switch. The switch has a stiff beam eliminating any stray mechanical forces. The switch has an excellent isolation of −90.9 dB (compared to − 58 dB in conventional designs ), the insertion of −0.2 dB, and a wide bandwidth of 88 GHz (compared to 40 GHz in conventional design ) making the switch suitable for wide band applications.

Numerical Analysis for Thermal Isolation on Plasma Etched silicon micro-structures (DRIE 식각을 이용한 대면적 실리콘 미세 구조물 부유 시 발생하는 열고립 현상 해석)

  • Lee, Yong-Seok;Jang, Yun-Ho;Kim, Jung-Mu;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1684-1685
    • /
    • 2011
  • This paper presents a theoretical and numerical analysis for thermal isolation of silicon micro-structures, especially for a large size with poor thermal conductivity, as well as straightforward solution for such an issue. Additional metal patterns underneath the silicon structures effectively reduces the thermal isolation. Heat transfer mechanism is analyzed using an equivalent circuit of thermal network including plasma, a heat source, heat capacitors, and thermal resistances. The FEM simulation was carried out to investigate the temperature change of silicon micro-structures according to process time. The temperature of silicon micro-structures with 2 ${\mu}m$ thick chrome layer at a steady state is $86^{\circ}C$, an approximately 40% decrease from the silicon microstructure without thin metal ($122^{\circ}C$)

  • PDF

Design of Dual-Band GPS Antenna Using a Single-Layer Coupled-Feed Structure (단층 간접급전구조를 이용한 이중대역 GPS 안테나 설계)

  • Hur, Jun;Byun, Gangil;Choo, Hosung;Kay, Youngchul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.9
    • /
    • pp.775-782
    • /
    • 2016
  • In this paper, we propose a dual-band GPS antenna using a single-layer coupled-feed structure for improvement of isolation and design complexity. The proposed antenna consists of a central feed patch and outer dual loops, and the loops are electromagnetically fed by the feed patch to induce currents. This feeding network can improve the isolation between antenna elements arranged in small arrays because the magnetic field strength near the antenna is minimized by confining the fields around the dual loops. The isolation characteristics of the proposed antenna are compared with those of the conventional multi-layer patch antenna, and the average field strength and the isolation are improved by 3 dB and 2 dB, respectively, which verifies that the antenna is suitable for small CRPA arrays.

A Rule-based Approach for the recognition of system isolation state using information on circuit breakers (차단기 정보를 이용한 계통의 분리 상태 인식의 룰-베이스적 접근)

  • Park, Y.M.;Lee, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.841-842
    • /
    • 1988
  • For determination of black-out area and restoration area by an expert system for fault section estimation and power system restoration using information from circuit breakers, it is necessary that the recognition of system isolation state and a method of finding the change of system isolation state by the state transition of breakers in isolated system. This paper presents a method of resolving the above problem by rule-based approach.

  • PDF

The Design of 128 Channels Cardiac-Activation Pre-Amplifier (128 채널 심장전기도 전치 증폭기의 설계)

  • Yoo, Sun-Kook;Chang, Byung-Chul;Jung, Dong-Il;Han, Young-Oh
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.11
    • /
    • pp.550-556
    • /
    • 2001
  • The computerized cardiac analysis system, which acquires and analyzes the electrical activation signal propagating along the surface of the heart, is indispensible equipment for the open heart surgery and electrical cardiac study. In this paper, the design requirement and the electrical circuit analysis are performed to construct the multi-channel cardiac activation pre-amplifier necessary for a signal conditioning circuit. The general 64 channel configuration is expanded into 128 channels to enhance the spatial resolution on the mapped surface of the heart. The 128 channels pre-amplifier consists of input circuit, differential amplifier, right leg driven circuit and isolation part. It has distinct features; high voltage protection, leakage current limitation, isolation and the maximization of common mode rejection ratio with respect to the half-cell potential difference due to different electrode materials. The final pre-amplifier circuit is assembled with 8 boards, each of which composing of 16 channels.

  • PDF

A dual-frequency and dual-polarization antenna with enhanced isolation between two ports using shorted metallic patches (Shorted metallic patch 를 이용하여 두 포트 사이의 고립도를 향상 시킨 이중대역 이중편파 안테나)

  • Lee, Dong-Hyun;Kim, Jae-Hee;Jang, Jong-Hun;Im, Yun-Taek;Park, Wee-Sang
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.67-68
    • /
    • 2006
  • A suspended microstrip line structure over mushroom-like SMPs is designed and is applied to a dual-frequency and dual-polarization microstrip patch antenna. This structure has a distinctive and sharp rejection band and provides near 0 dB insertion loss outside the rejection band. Applying the structure to the conventional DFDP antenna enhanced the isolation between the two ports more than 20 dB. The structure is expected to have a wide range of applications in antennas and filters due to its compactness and integrability in circuits.

  • PDF

Analysis and Design of a PFC AC-DC Converter with Electrical Isolation

  • Lin, Chia-Ching;Yang, Lung-Sheng;Zheng, Ren-Jun
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.874-881
    • /
    • 2014
  • This study presents a single-phase power factor correction AC-DC converter that operates in discontinuous conduction mode. This converter uses the pulse-width modulation technique to achieve almost unity power factor and low total harmonic distortion of input current for universal input voltage $90V_{rms}$ to $264V_{rms}$) applications. The converter has a simple structure and electrical isolation. The magnetizing-inductor energy of the transformer can be recycled to the output without an additional third winding. The steady-state analysis of voltage gain and boundary operating conditions are discussed in detail. Finally, experimental results are shown to verify the performance of the proposed converter.

Development of the Electromagnetic Field Water Treater System (전자장 수처리 시스템 개발)

  • Kim, Sang-Uk;Kim, Jin-Hwan;Kim, Bo-Youl;Kim, Young-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.142-145
    • /
    • 2002
  • This paper presents the electromagnetic field water treater system with the high performance for a good quality of water. The electromagnetic field water treater consists of a solion, a solion body. and a high voltage converter. The high voltage converter is controlled by PWM current controller. The high voltage converter of 13W is designed for an isolation operation ramp. an isolation current detector, and an over current protector. Using the high voltage PWM converter, the system with the proposed electromagnetic field water treater can be controlled easily. Simulation and experimental results show the effectiveness of the system strategy proposed for the scale rejection.

  • PDF

A Study on the Nitride Residue and Pad Oxide Damage of Shallow Trench Isolation(STI)-Chemical Mechanical Polishing(CMP) Process (STI-CMP 공정의 질화막 잔존물 및 패드 산화막 손상에 대한 연구)

  • Lee, U-Seon;Seo, Yong-Jin;Kim, Sang-Yong;Jang, Ui-Gu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.9
    • /
    • pp.438-443
    • /
    • 2001
  • In the shallow trench isolation(STI)-chemical mechanical polishing(CMP) process, the key issues are the optimized thickness control, within-wafer-non-uniformity, and the possible defects such as pad oxide damage and nitride residue. The defect like nitride residue and silicon (or pad oxide) damage after STI-CMP process were discussed to accomplish its optimum process condition. To understand its optimum process condition, overall STI related processes including reverse moat etch, trench etch, STI fill and STI-CMP were discussed. Consequently, we could conclude that law trench depth and high CMP thickness can cause nitride residue, and high trench depth and over-polishing can cause silicon damage.

  • PDF

Magnetic Properties and Microstructures of Co-Cr-(Pt)-Ta Magnetic Thin Films Sputtered on Self-textured Substrates

  • Shin, Kyung-Ho;Chang, Han-Sung;Lee, Taek-Dong;Park, Joong-Keun
    • Electrical & Electronic Materials
    • /
    • v.11 no.10
    • /
    • pp.72-77
    • /
    • 1998
  • The effects of Al micro-bumps on the magnetic properties of CoCr(Pt)Ta/Cr films deposited on glass substrates were investigated. The coercivity increased and the coercivity squareness decreased by incorporating Cr/Al underlayers. The cause of the coercivity increase is attributed to the reduction of Co(0002) texture, the increase of magnetic isolation of CoCr(Pt)/Ta grains, and the refinement of CoCr(Pt)/Ta grains deposited on Cr/Al underlayers. The effects of an Al overlayer on the magnetic properties of CoCr(Pt)Ta/Cr films were also studied. The decrease of coercivity squareness is ascribed to the magnetic isolation of CoCr(Pt)Ta grains.

  • PDF