• 제목/요약/키워드: Electrical Equipments

검색결과 862건 처리시간 0.023초

비상용 발전설비 진단시스템 개발 (Development of the Emergency Generator Equipments Diagnosis System)

  • 이상철;나채동;이성범;유재문;최식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 F
    • /
    • pp.2590-2593
    • /
    • 1999
  • This paper describes the development of Emergency Generator Equipments Diagnosis System for monitoring generator equipments and battery system. This system is capable of measuring on up to 20 separate sites of generator, engine and periphral equipment's. Battery system also capable of measure the setting time, float and discharge voltage of up to 240 cells in a single installation, and has the memory capacity to store battery's alarm data information on up to 200 separate sites. This system are easy to maintain and attain cost effectively, so that prepared for meeting the customer's service needs immediately. The system is additionally programmed with a each model, that will enable to accurately determine the generator equipments and remain battery capacity in a system following a short discharge test. It is also equipped with remote interrogation and control facilities.

  • PDF

각종 보조설비와 연계된 열병합발전시스템에서 퍼지이론을 적용한 단기운전계획수립 (Shot -term Operation Scheduling Using Fuzzy Theory on Cogeneration Systems Connected with Auxiliary Equipments)

  • 이종범;정창호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.553-555
    • /
    • 1995
  • This paper presents the optimal short-term operation scheduling by using on cogeneration systems connected with auxiliary equipments. Simulation is performed in case of the bottomming cycle which generates the demand heat preferentially. Heat storage tank, electricity charger, auxiliary boiler and independent generator are considered as auxiliary equipments connected to cogeneration systems. The results of simulation show the auxiliary equipments can be effeciently operated in case of the bottomming cycle by modeling proposed in this paper. The effectiveness of operation scheduling gained by application of fuzzy theory is evaluated by detailed comparison and investigation of the simulation results.

  • PDF

폐쇄 배전반에서의 부분 방전 On-Line 열화 감시 시스템 개발 (Development of electromagnetic wave detecting equipment for diagnosis of partial discharge in enclosed switchboard)

  • 전광호;강창원;김재철;김광화;강대수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.318-320
    • /
    • 2000
  • This paper presents the develop-ment of electromagnetic wave detecting equipment for diagnosis of enclosed switchboard. High voltage power equipments are very important equipment of the key industries and the private enterprise power line accidents are national plans because of those set off casualties lose of power equipments and communication networks. Therefore the necessity of the development of detecting for power equipment diagnosis is demand for prevention of high voltage equipment accidents. This paper is the development of electromagnetic wave detecting equipment for diagnosis of high voltage equipment. This paper establishes the diagnosis method for high voltage power equipments, that secures original technique and possesses detecting technique for electromagnetic wave. By the study we developed electromagnetic wave detector and we applied this equipment application tests at the place constructed high voltage equipments.

  • PDF

하이브리드 자동차용 고압 케이블의 온도 특성에 관한 연구 (A Study on the Temperature Characteristics of High Voltage Power Cable for Hybrid Electric Vehicle)

  • 이기연;김동우;김동욱;길형준;김향곤;최충석
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.338-342
    • /
    • 2008
  • Hybrid Electric Vehicle(HEV) is driven by an internal-combustion engine and an electric motor. It is a combination of an internal-combustion engine and several electrical equipments which use a high voltage battery, an electric motors, an inverter and others. But there is not any separate detailed enforcement regulations for high voltage electric appliances in the existing vehicle-related safety standards. So, test standards suggestion as well as test technique development need to be done for ensuring electrical safety, for an electric motor, a high voltage battery, a(n) inverter/converter and an electric power transmission units and other equipments to ensure the safety of high voltage electric appliances which is the HEV key electrical component. In this paper, We are to provide helpful data to support test technique development and test standard establishment for HEV design and electrical safety security by the following methods; by measuring the voltage, the electric current, and the frequency of HEV, by analyzing electrical characteristics of high voltage electric appliances, and by analyzing temperature characteristics of the electrical current among the analyzed electrical characteristics by thermal imagining cameras.

고속 비행체 전자 장비의 안전성 예측을 위한 열해석 모델 구축 (The Development of Thermal Model for Safety Analysis on Electronics in High-Speed Vehicle)

  • 이진관;이민정;황수권
    • 한국항공우주학회지
    • /
    • 제49권5호
    • /
    • pp.437-446
    • /
    • 2021
  • 비행체의 속도가 빨라질수록, 비행 시 발생하는 공력 가열이 커진다. 고속 비행체의 속도가 빨라지면서 비행체의 외피는 수백 ℃까지 가열되기도 하며, 동시에 동체 내부의 전자장비들도 함께 가열되어 상대적으로 사용온도가 낮은 전자장비들의 열적 안전성이 위협받기 시작하였다. 이에 따라 개발 단계에서 전자장비의 온도 예측 및 외부시스템을 이용한 온도 조절 등 장비의 열적 안전성을 예측하고, 이를 확보하기 위한 다양한 시도가 있었다. 본 논문에서는 일회성 고속 비행체 내 장비의 열적 안전성을 예측할 수 있는 열 해석 모델을 구축하는 기술을 개발하였다. 장비 내부의 열전달 특성을 파악하기 위한 간단한 지상 모사실험을 수행하였고, 그 결과를 바탕으로 열전달 특성을 모사한 열 해석모델을 구축하였다. 이 기술을 활용하여 장비 열 해석 모델을 구축한다면, 비행 시장비 내부 구성품별 온도 변화를 예측할 수 있고, 더 나아가 열에 가장 취약한 특정 소자의 온도를 예측할 수 있기 때문에 더 정밀한 열적 안전성 예측이 가능하다.

A Study on the Electrical Strength of Insulating Materials for High-Tc Superconducting Devices

  • Bae, Duck Kweon;Kim, Chung-Hyeok;Pak, Min-Sun;Oh, Yong-Cheul;Kim, Jin-Sa;Shin, Cheol-Gee;Lee, Joon-Ung;Song, Min-Jong;Choi, Woon-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제6권6호
    • /
    • pp.294-300
    • /
    • 2005
  • According to the trend for electric power equipment of high capacity and reduction of its size, the needs for the new high performance electric equipments become more and more important. On of the possible solution is high temperature superconducting (HTS) power application. Following the successful development of practical HTS wires, there have been renewed activities in developing superconducting power equipment. HTS equipments have to be operated in a coolant such as liquid nitrogen ($LN_2$) or cooled by conduction-cooling method such as using Gifford-McMahon (G-M) cryocooler to maintain the temperature below critical level. In this paper, the dielectric strength of some insulating materials, such as unfilled epoxy, filled epoxy, and polyimide in $LN_2$ was analyzed. Epoxy is a good insulating material but fragile at cryogenic temperature. The filled epoxy composite not only compensates for this fragile property but enhances its dielectric strength.

전파응용설비 관리제도 개선방안 연구 (A Study on an Improvement Scheme of ISM Management Regulation)

  • 박연규;조현묵;이일규
    • 한국전자파학회논문지
    • /
    • 제27권7호
    • /
    • pp.581-587
    • /
    • 2016
  • 최근 전파응용설비의 다양화 및 50와트를 초과하는 고출력 설비의 이용이 가정, 의료기관 및 산업현장에서 확대됨에 따라 허가대상 설비가 대폭 증가하였다. 이로 인해 각각의 설비를 개별적으로 허가하고, 전수를 검사하는 현재의 허가체계는 한계성을 가지고 있으며, 환경변화 등의 현실을 반영하기 어렵다. 본 논문에서는 해외 주요국의 전파응용설비 관련제도와 국내 제도를 조사하고, 이를 토대로 국내 환경에 적합한 전파응용설비 관리제도 개선방안을 제안하였다. 이 결과는 향후 전파응용설비 관련 산업 활성화와 전파응용설비의 효율적인 관리를 위한 전파응용설비 관리제도를 개선하는데 유용한 자료로 사용될 것이다.

자외선 검출 카메라를 이용한 전력시스템의 안전진단에 관한 연구 (A Study on the Safety Diagnosis for Power Systems Using a UV Camera)

  • 유병열;김찬오
    • 한국안전학회지
    • /
    • 제27권1호
    • /
    • pp.7-13
    • /
    • 2012
  • This paper describes the diagnosis techniques using UV images taken in the field under energized condition of power equipments in order to figure out and analyze the abnormal states on the terminals of power equipments. To classify the features of the terminals, the counted No. of the corona generated at the terminals is defined. According to the result detected, the No. of corona detected on the power equipments installed inside a building is less than that installed outside a building, and it strongly depends on the environment and installed condition. Thus, the environmental condition needs enhanced, and stable operation by the periodic inspection under energized condition of the power equipments is required. Especially, the event counting technique using UV camera is useful for the power equipments apart more than 20 m to apply, and there can be an error due to the features of the sensing techniques when the distance between the user and the objects is close less than 15 m. Therefore, the experimental result shows that event counting technique is employed in the case of the distance more than 15 m. The electrical safety can be ensured by using the UV detection technique and the criteria.

고압중전기기용 절연신소재 EMNC와 EMNSC의 특성연구 (Properties of EMNC and EMNSC for Insulation New Material as Apply to High Voltage Heavy Electric Machine)

  • 박재준
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1454-1460
    • /
    • 2012
  • In order to develop an new electric insulation material for heavy electric equipments, epoxy/micro/nano composite (EMNC) was prepared by mixing micro-silica with nano layered silicate, where the nano layered silicate was synthesized by our electric field dispersion method, EMNSC was prepared by treating the EMNC with a silane coupling agent. Thermal properties such as glass transition temperature (Tg) and thermal expansion coefficient, and DMA characteristics were studied, and mechanicla properties such as tensile and flexural tests were performed. AC electrical insulation strength was also tested. All properties of EMNSC were modified by treating EMNC with silane coupling agent and it was confirmed that our new developed composites could be used in the heavy electric equipments.

SPD의 설치조건이 보호효과에 미치는 영향 (Protection Effects Associated with Installation Conditions of SPD)

  • 이복희;이동문;정동철;이승칠
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.298-302
    • /
    • 2005
  • This paper presents the protection effect of SPDs according to installation conditions. To develop the effective protection countermeasures of information and communication equipments against lightning surges, actual-sized experiments in relation to the protection effects on the installation positions of surge protective devices(SPDs), the length of branch circuit the materials and long of conduit were conducted. The best method for protecting the electronic equipments from surges is to install the SPD at the front point of the devices to be protected. The installation method of the metal conduit bonded with common ground conductor were more effective than that of the PVC conduit.

  • PDF