• 제목/요약/키워드: Electrical Contact

Search Result 2,095, Processing Time 0.041 seconds

Electrical properties and thermal stability of Al/$WN_x$/Ti submicron contact structure

  • Kim, Yong-Tae;Sim, Hyun-Sang;Kim, Seong-Il
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2002.11a
    • /
    • pp.72-74
    • /
    • 2002
  • A submicron contact scheme using $WN_x$ diffusion barrier has been suggested for multilevel interconnect structure. The contact resistance of $0.4\times0.48\mu\textrm{m}^2$ size Al/WN/Ti/$n^+$-Si is 120-140 $\Omega$ and the leakage current density is below than $10^{-16}$$-10^{-15}A/\mu\textrm{m}^2$. The effect of F atoms on the submicron contact has been investigated with the nuclear resonance analysis method.

  • PDF

Development of an Improved RF Dosimeter (개량된 비접촉형 RF 선량계 구현)

  • Son, Jong-Dea;Lee, Seung-Min;Lee, Heung-Ho;Lee, Nam-Ho;Lee, Seung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.540-543
    • /
    • 2003
  • This paper presents design and manufacture of RF type non-contact radiological dosage measuring device. It also concerns on the broad out-line and the ways of improvement about RF type non-contact radiation measuring device. Measuring radiological dosage with non-contact RF, the stability and efficiency of the measure have been improved by reforming constant current circuit. Furthermore, applying communication protocol in process makes it possible to achieve faster and more accurate communication than old circuit. On the base of those, RF type non-contact radiological dosage measuring device which consists of radiological dosage measuring module and Reader module has been designed and manufactured. While testing communication against embodied device, the possibility of the field application could be confirmed.

  • PDF

A Study on Installation of Monitoring System of Wireless Power Transmission System (무선전력전송 시스템의 모니터링 시스템 구축에 관한 연구)

  • Song, Young-Sang;Han, Woon-Ki;Jung, Jin-Soo;Lim, Hyun-Sung;Cho, Sung-Koo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.4
    • /
    • pp.47-53
    • /
    • 2015
  • The electrical safety and efficiency is the most important thing of the electric vehicle charging system. The prior system is contact charging system that is contacted directly by human. So, it has riskiness such as electric shock in the case of poor insulation or contact problems. To solve these safety issues and the convenience problems, a wireless power transmission system has been developed and is currently in trial operation. However, because high frequency is used in wireless power transmission system instead of commercial frequency, we need to apply protection measures concerning electric shock and equipment protection. Also, it should be accompanied by measuring efficiency for the effective operation of the wireless power transmission system. Therefore, we structured monitoring system in trial operation area of wireless power transmission system and applied decision algorithm for protection of human and equipment and economic operation of it.

A effect of the efficiency for the back contact silicon solar cell with the surface texturing depth and gap (표면 텍스쳐링 깊이와 간격에 따른 후면 전극 실리콘 태양전지 효율에 미치는 영향)

  • Jang, Wang-Geun;Jang, Yun-Seok;Park, Jung-Il;Pak, Jung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1380-1381
    • /
    • 2011
  • 본 논문에서는 SILVACO 사의 ATHENA와 ATLAS를 이용하여 후면 전극 실리콘 태양전지 (back contact silicon solar cell)의 전면 텍스쳐링 (texturing) 깊이 (depth)와 텍스쳐링 간격 (gap)에 따른 태양전지 효율(efficiency)에 미치는 영향을 분석하였다. 제안한 후면 전극 실리콘 태양전지는 (100) silicon wafer(n-type, $6{\times}10^{15}\;cm^{-3}$)을 기반으로 전면부에 텍스쳐링을, 후면부에 BSF(back surface field, $1{\times}10^{20}\;cm^{-3}$)와 에미터(emitter, $8.5{\times}10^{19}\;cm^{-3}$)를 구성하고, 셀간 피치를 1250 ${\mu}m$, BSF와 에미터의 간격을 25 ${\mu}m$으로 한 구조이다. 텍스쳐링 간격이 없이 텍스쳐링 깊이를 0 ${\mu}m$에서 150 ${\mu}m$으로 증가시켜 분석한 결과, 텍스쳐링 깊이가 증가할수록 효율이 23.90%에서 25.79%로 증가하였다. 텍스쳐링 간격을 1 ${\mu}m$에서 100 ${\mu}m$으로 증가시켜 분석한 결과, 텍스쳐링 깊이와 상관없이 텍스쳐링 간격이 증가할수록 후면 전극 실리콘 태양전지의 효율이 감소하였다. 텍스쳐링 유무에 따라 후면 전극 태양전지의 외부양자효율의 차이를 보였고 텍스쳐링이 있을 때 외부양자효율이 보다 높은 값을 얻었다.

  • PDF

Investigation on the P3HT-based Organic Thin Film Transistors (P3HT를 이용한 유기 박막 트랜지스터에 관한 연구)

  • Kim, Y.H.;Park, S.K.;Han, J.I.;Moon, D.G.;Kim, W.G.;Lee, C.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.04b
    • /
    • pp.45-48
    • /
    • 2002
  • Poly(3-hexylthiophene) or P3HT based organic thin film transistor (OTFT) array was fabricated on flexible poly carbonate substrates and the electrical characteristics were investigated. As the gate dielectric, a dual layer structure of polyimide-$SiO_2$ was used to improve the roughness of $SiO_2$ surface and further enhancing the device performance and also source-drain electrodes were $O_2$ plasma treated for improvement of the electrical properties, such as drain current and field effect mobility. For the active layer, polymer semiconductor, P3HT layer was printed by contact-printing and spin-coating method. The electrical properties of OTFT devices printed by both methods were evaluated for the comparison. Based on the experiments, P3HT-based OTFT array with field effect mobility of 0.02~0.025 $cm^{2}/V{\cdot}s$ and current modulation (or $I_{on}/I_{off}$ ratio) of $10^{3}\sim10^{4}$ was fabricated.

  • PDF

Fire Cause Analysis of Local Heating on Carbon Type Hot Wire Electric Pad (카본열선을 사용하는 전기장판의 국부가열에 의한 화재원인 분석)

  • Song, Jae-Yong;Kim, Jin-Pyo;Nam, Jung-Woo;Sa, Seung-Hun
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.104-108
    • /
    • 2010
  • This paper describes electrical fire on electric pad using carbon type hot wires. A carbon type hot wires electric pad is virtually impossible to connect hot wire as a method of electrical welding or soldering. In order to connect between hot wires, that has to splice carbon type material connector. If junction of hot wires was occurrence of poor connection on electric pad, it increase contact resistance on this junction point. With increasing contact resistance, junction of hot wires on electric pad generates local heating and finally leads to electrical fire. In this paper, we analyzed shape of damage in hot wires caused by electrical local heating and investigated fire cause on electric pad using by carbon type hot wires.

A Study on Calcium Ion Reduction in Power Plant Water using High Voltage Impulse (고전압 임펄스를 활용한 발전용수 칼슘농도 저감에 관한 연구)

  • Kim, TaeHui;Chang, In-Soung;Jung, Jae-Hwan;Hong, Woong ki;Lee, June-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.3
    • /
    • pp.545-550
    • /
    • 2017
  • As an alternate technique for water softening, high voltage impulse (HVI) is introduced and verified if it can control the $CaCO_3$ scale formation in industrial water treatment. After HVI was applied to the artificial hard water containing $100{\pm}5mg/L$ $Ca^{2+}$ for 4 hours, the $Ca^{2+}$ concentration and the electrical conductivity were measured. The concentration of $Ca^{2+}$ was reduced from 94.5 to 86.3 mg/L (8.7% reduction) after 4 hour contact of HVI under 5 kV condition. The $Ca^{2+}$ was decreased from 92 to 77.7 mg/L (15.6% reduction) at 8kV and from 90.1 to 75.4 mg/L (16.3% reduction) at 12 kV condition. Both of the contact time and the applied voltage were important parameters affecting the calcium ion reduction. With these results, it was verified that HVI technique could be potential candidate for control of $CaCO_3$ scale formation.

Study on Improvement of Electrical Relay by Using MOSFET Electronic Switch (제어 계측분야에서 MOSFET를 사용한 Relay 성능향상에 관한 연구)

  • Park, Hyun-Su;Park, Hyun-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.364-364
    • /
    • 2010
  • In the electricity control field, a relay is the most widely used electrical switch. But it has problems about a material transfer phenomenon, contact bounce, and the mechanical life. These Problems cause the serious problem in a facility. So, we tried to solve these problems by applying MOSFET electronic switch and could find good improvement compared to conventional electrical switch.

  • PDF

Errects of $SiH_4/WF_6$Ratio on the Electrical Properties of LPCVD W Films for Contact Metal (Contact Barrier metal용 LPCVD W막의 전기적 특성에 대한 $SiH_4/WF_6$비의 효과)

  • Lee, Jong-Mu;Park, Won-Gu;Im, Yeong-Jin;Son, Jae-Hyeon;Kim, Hyeong-Jun
    • Korean Journal of Materials Research
    • /
    • v.3 no.6
    • /
    • pp.661-667
    • /
    • 1993
  • Effects of $SiH_4//WF_6$(=R) ratio on the electrical properties of W films such as resistvity, contact resistance, junction leakage current in the selective W CVD technology for contact barrier metal were investigated with the emphasis on the role of $\alpha$-W Resistivity of W increases with increasing R, which is primarily due to the phase transformation from $\alpha$-W to , $\alpha$-W. $\alpha$-W found in the SiH4 reduced CVD W film is stabilized by Si incorporated into the W film rather than by oxygen. $\alpha$-W is found in the W film deposited on the Si substrate for high R, while $\alpha$-W is not found in the W film deposited on the TiN substrate even for high R. Also junction leakages increase with increasing R, which is caused not only by the vertical Si consumption but also the lateral Si consumption.

  • PDF