• 제목/요약/키워드: Electrical Contact

검색결과 2,093건 처리시간 0.029초

Pressure Contact Interconnection for High Reliability Medium Power Integrated Power Electronic Modules

  • Yang, Xu;Chen, Wenjie;He, Xiaoyu;Zeng, Xiangjun;Wang, Zhaoan
    • Journal of Power Electronics
    • /
    • 제9권4호
    • /
    • pp.544-552
    • /
    • 2009
  • This paper presents a novel spring pressure contact interconnect technique for medium power integrated power electronics modules (IPEMs). The key technology of this interconnection is a spring which is made from Be-Cu alloy. By means of the string pressure contact, sufficient press-contact force and good electrical interconnection can be achieved. Another important advantage is that the spring exhibits excellent performance in enduring thermo-mechanical stress. In terms of manufacture procedure, it is also comparatively simple. A 4 kW half-bridge power inverter module is fabricated to demonstrate the performance of the proposed pressure contact technique. Electrical, thermal and mechanical test results of the packaged device are reported. The results of both the simulation and experiment have proven that a good performance can be achieved by the proposed pressure contact technique for the medium power IPEMs.

전차선의 집전상태 판단 알고리즘 구현 (On the Implementation of an Advanced Judgement Algorithm for Contact Loss of Catenary System)

  • 박영;정호성;윤일권;김원하
    • 전기학회논문지
    • /
    • 제63권6호
    • /
    • pp.850-854
    • /
    • 2014
  • Analyzing dynamic performance between pantograph and contact wire depends on mechanical and electrical conditions such as contact force, currents, aerodynamics of pantograph and tension of overhead contact wire. For the characteristic of dynamic performance between pantograph and overhead contact wire, various evaluation systems are used to measuring of the interaction of the contact line and the pantograph. Among the various methods, the contact force and percentage of arcing are intended to prove the safety and the quality of the current collection system on the train. However, these methods are only capable of measuring on the train which are installed measurement systems. Therefore in this paper, a track-side monitoring system was implemented to measure electrical characteristics from active overhead contact wire systems in order to constantly estimate current collection performance of railway operation. In addition, a method to analyze loss of contact phenomena was proposed. According to simulation results, the proposed system was capable of measuring abnormal electrical behavior of pantograph and contact wires on the track-side. The advantage of the proposed system is possible to detect loss of contact or any other electrical abnormalities of all types of trains within sections from sub to sub without the need to install any on-board equipment on trains.

Ti Self-Aligned Silicide를 이용한 Contact에서의 전기적 특성 (Electrical Characteristics of Ti Self-Aligned Silicide Contact)

  • 이철진;허윤종;성영권
    • 대한전기학회논문지
    • /
    • 제41권2호
    • /
    • pp.170-177
    • /
    • 1992
  • Contact resistance and contact leakage current of the Al/TiSiS12T/Si system are investigated for NS0+T and PS0+T junctions. SALICIDE (Self Aligned Silicide) process was used to make the Al/TiSiS12T/Si system. Titanium disilicide is one of the most common silicides because of its thermal stability, ability to form selective formation and low resistivity. In this paper, RTA temperature effect and Junction implant dose effect were evaluated to characterize contact resistance and contact leakage current. The TiSiS12T contact resistance to NS0+T silicon is lower than that to PS0+T silicon, and TiSiS12T of contact leakage current to NS0+T silicon is lower than that to PS0+T silicon. Contact resistance and contact leakage current of the Al/TiSiS12T/Si system by this method were possible for VLSI application.

Electrical Contact Characteristics of Ag-SnO2 Materials with Increased SnO2 Content

  • Chen, Pengyu;Liu, Wei;Wang, Yaping
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권6호
    • /
    • pp.2348-2352
    • /
    • 2017
  • The electrical contact characteristics including temperature rise, contact resistance and arc erosion rate of the $Ag-SnO_2$ materials with increased $SnO_2$ content were investigated during the repeated make-and-break operations. The thickness of arcing melting layer reduces by half and the arc erosion rate decreases more than 70% under 10000 times operations at AC 10 A with the $SnO_2$ content increasing from 15 wt.% to 45 wt.%, on one hand, temperature rise and contact resistance increase obviously but could be reduced to the same order of conventional $Ag-SnO_2$ materials by increasing the contact force. The microstructure evolution and the effect of $SnO_2$ on the arc erosion, contact resistance were analyzed.

전기접촉저항에 관한 접촉통계치의 영향 (Effect of Contact Statistics on Electrical Contact Resistance)

  • 장용훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1080-1085
    • /
    • 2003
  • The flow of electrical current through a microscopic actual contact spot between two conductors is influenced by the flow through adjacent contact spots. A smoothed version of this interaction effect is developed and used to predict the contact resistance when the statistical size and spatial distribution of contact spots is known. To illustrate the use of the method, an idealized fractal rough surface is defined using the random midpoint displacement algorithm and the size distribution of contact spots is assumed to be given by the intersection of this surface with a constant height plane. With these assumptions, it is shown that including finer scale detail in the fractal surface, equivalent to reducing the sampling length in the measurement of the surface, causes the predicted resistance to approach the perfect contact limit.

  • PDF

고속전철 주행시 이선에 따른 전원외란 현상 모델링 및 시뮬레이션 구현 (A Modeling and Simulation Implementation on the Power Line Disturbances by Loss of Contact for the High-Speed Railway Vehicle)

  • 김재문;김양수;장진영;김윤명
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1137-1142
    • /
    • 2008
  • In this paper, an effect on power conversion unit in high-speed railway vehicle by loss of contact between a catenary system and pantograph suppling electrical power to high-speed railway vehicle are investigated. One of the most important needs accompanied by increasing the speed of high-speed railway vehicle is reduced that arc phenomenon by loss of contact brings out EMI. in case of high-speed railway vehicle using electrical power, as comparison with diesel rolling stock, PLD(Power Line Disturbance) such as harmonic, transient voltage and current, EMI, dummy signal injection etc usually occur. To analysis the effect on loss of contact, it is necessary electrical modeling system between the contact line and the pantograph according to the loss of contact. Therefore analytical model of a contact line and a pantograph is constructed to simulate the behaviour of loss of contact. The reliability of the modeling system is verified by simulation implementation on kinds of loss of contact.

  • PDF

초고압 단로기 접점의 단락전류 통전성능 평가기술 개발 (Development of Evaluating Technology for the Capability of Carrying Short-Circuit Current at Electrical Contacts in EHV Disconnecting Switches)

  • 오연호;송기동;정진교
    • 전기학회논문지
    • /
    • 제57권1호
    • /
    • pp.46-51
    • /
    • 2008
  • Extra-high voltage(EHV) disconnecting switch(DS) consists of the electrical contacts and mechanical parts which actuate the contacts. When the short-circuit condition occurs, a large amount of current flows through the electrical contact in disconnecting switches and this causes considerable temperature rise due to Joule heating. If the temperature rise is higher than the melting point of contact material, the DS contact becomes melting and cannot be usable anymore. For this reason, the analysis for capability of carrying short-circuit current in DS contacts must be performed at a design stage. Here, we proposed a numerical technique for evaluating the capability of carrying short-circuit current at electrical contacts in EHV DS. In this numerical approach, the mechanical and thermal analyses were simulated to check the capability of carrying short-circuit current. First, the applied pressure at contact parts was analyzed considering the mechanical properties, and then contact resistance was calculated by an empirical equation. Finally, thermal analysis was performed with resistance variation at electrical contacts. To verify these numerical results, the distributions of temperature in DS were experimentally measured and compared with each other. The results from experiments were agreed well with those from the proposed numerical simulations.

Cu25Cr 접점재료의 성형압력에 따른 소결 및 전기적 특성에 관한 연구 (A study on the effects of compacting pressure on the electrical & sintering characteristics of Cu25Cr contact material)

  • 연영명;박홍태;오일성;이경행
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.1065-1068
    • /
    • 2001
  • Effects of compacting pressure on the electrical and sintering characteristics of Cu25Cr contact material have been investigated. Cu25Cr contact materials were prepared by solid and liquid-phase sintering methods varying compacting pressure. Influence of compacting pressure on electrical characteristics were investigated in the cylindrical stainless-steel vessel using L-C resonant circuit. The physical and electrical properties of solid-phase sintered Cu25Cr material were found to be improved by increased compacting pressure. On the other hand, it was found that compacting pressure had little influence in case of liquid-phase sintered Cu25Cr material. After conditioning, contact resistance of Cu25Cr material was decreased regardless of compacting pressure. With increased compacting pressure, interrupting ability was shown to be increased.

  • PDF

Analysis of Contact Force in Eddy-current System Using the Virtual Air-Gap Concept

  • Park, Byung Su;Kim, Hwi Dae;Choi, Hong Soon;Park, Il Han
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1349-1355
    • /
    • 2015
  • It is difficult to calculate the magnetic force of an object of magnetic material in contact with other objects using the existing methods, such as Maxwell stress tensor method, magnetic charge method, or magnetizing current method. These methods are applicable for force computation only when the object is surrounded by air. The virtual air-gap concept has been proposed for calculating the contact force. However, its application is limited to magneto-static system. In this paper, we present the virtual air-gap concept for contact surface force in the eddy-current system. Its validity and usefulness are shown by comparison between numerical and experimental examples.

전기적 신호와 열적특성 분석에 의한 접촉불량 예측 (Prediction of Poor Contact by Analysis of Electrical Signal and Thermal Characteristics)

  • 이흥수;김두현;김성철;김윤복
    • 한국안전학회지
    • /
    • 제27권3호
    • /
    • pp.36-41
    • /
    • 2012
  • Electrical Connections often cause fires due to poor contact. Occurrence rate of these fires tends to increase annually. The reason why poor contacts occur is often because it is the low mechanical pressure at the contact points. A typical connection method using mechanical pressure is a screw terminal type. This study reviewed these poor contact cases in the screw terminals. In order to get reproduction of such cases, two types of experiments were conducted. the first one was conducted under the normal contact condition, and the other one was conducted under the poor contact condition that screw terminal of breaker was loosen and did not meet the requirements of toque value. In both types of experiments, compulsory vibration was adopted as a variable to aggravate poor contacts. Each of various current values(4.5A, 9.0A, 13.5A) is input. In these experiments, relationships of a contact, electrical signal such as current and electric pulse by ZCT and thermal characteristics according to vibration effect are analyzed. The suggested data and results in this study provide the useful resources helping to investigate fires due to poor contact, and they develop the detector for poor contact and finally reduce the electrical fire occurrence rate.