• Title/Summary/Keyword: Electrical Contact

Search Result 2,093, Processing Time 0.032 seconds

Development of an Uplift Measurement System for Overhead Contact Wire using High Speed Camera (고속카메라를 이용한 전차선 압상량 검측 시스템 개발)

  • Park, Young;Cho, Yong-Hyeon;Lee, Ki-Won;Kim, Hyung-Jun;Kim, In-Chol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.10
    • /
    • pp.864-869
    • /
    • 2009
  • The measurement of contact wire uplift in electric railways is one of the most important test parameters to accepting the maximum permitted speed of new electric vehicles and pantographs. The contact wire uplift can be measured over short periods when the pantograph passes monitoring stations. In this paper, a high-speed image measurement system and its image processing method are being developed to evaluate dynamic uplift of overhead contact wires caused by pantograph contact forces of Korea Tilting Train eXpress (TTX) and Korea Train eXpress (KTX). The image measurement system was implemented utilizing a high-speed CMOS (Complementary Metal Oxide Semiconductor) camera and gigabit ethernet LAN. Unlike previous systems, the uplift measurement system using high speed camera is installed on the side of the rail, making maintenance convenient. On-field verification of the uplift measurement system for overhead contact wire using high speed camera was conducted by measuring uplift of the TTX followed by operation speeds at the Honam conventional line and high-speed railway line. The proposed high-speed image measurement system to evaluate dynamic uplift of overhead contact wires shows promising on-field applications for high speed trains such as KTX and TTX.

Contact resistance in graphene channel transistors

  • Song, Seung Min;Cho, Byung Jin
    • Carbon letters
    • /
    • v.14 no.3
    • /
    • pp.162-170
    • /
    • 2013
  • The performance of graphene-based electronic devices is critically affected by the quality of the graphene-metal contact. The understanding of graphene-metal is therefore critical for the successful development of graphene-based electronic devices, especially field-effect-transistors. Here, we provide a review of the peculiar properties of graphene-metal contacts, including work function pinning, the charge transport mechanism, the impact of the process on the contract resistance, and other factors.

Electrical performance and contact resistance with the substrate temperature in the pentacene organic thin-film transistors

  • Lee, Cheon-An;Jang, Kyoung-Chul;Kim, Sung-Won;Ryoo, Ki-Hyun;Jin, Sung-Hun;Lee, Jong-Duk;Shin, Hyung-Cheol;Park, Byung-Gook
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1317-1319
    • /
    • 2005
  • Bottom contact pentacene organic thin-film transistors are fabricated at three different substrate temperatures, $70^{\circ}C$, $80^{\circ}C$ and $90^{\circ}C$. The maximum effective mobility was obtained at $80^{\circ}C$. The contact resistance was extracted by applying two different methods, TLM method and channel-resistance method, and the value shows the minimum at $80^{\circ}C$, which is thought to be the important reason for the best performance.

  • PDF

Characterization of Density-of-States in Polymer-based Organic Thin Film Transistors and Implementation into TCAD Simulator

  • Kim, Jaehyeong;Jang, Jaeman;Bae, Minkyung;Lee, Jaewook;Kim, Woojoon;Hur, Inseok;Jeong, Hyun Kwang;Kim, Dong Myong;Kim, Dae Hwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.1
    • /
    • pp.43-47
    • /
    • 2013
  • In this work, we report extraction of the density-of-states (DOS) in polymer-based organic thin film transistors through the multi-frequency C-V spectroscopy. Extracted DOS is implemented into a TCAD simulator and obtained a consistent output curves with non-linear characteristics considering the contact resistance effect. We employed a Schottky contact model for the source and drain to fully reproduce a strong nonlinearity with proper physical mechanisms in the output characteristics even under a very small drain biases. For experimental verification of the model and extracted DOS, 2 different OTFTs (P3HT and PQT-12) are employed. By controlling the Schottky contact model parameters in the TCAD simulator, we accurately reproduced the nonlinearity in the output characteristics of OTFT.

The Heating of Cu-oxide and Arc Properties according to Electrical Poor Contact (전기적 불완전 접촉에 따른 동산화물의 발열 및 아크 특성)

  • Kim, Wansu;Park, SangJune;Hwang, DongHyun
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.3
    • /
    • pp.15-20
    • /
    • 2019
  • As industry is progressing and standards of living are improved, the demand of electrical energy is expected to grow 8-9% annually. Therefore, the importance of electrical fire prevention technology with the ability of the power supply is being emphasized. According to the statistics of fire in Korea, fire occurred about 45,000 cases annually, and electrical fire possessed about 20%. The electrical fire by poor contact has increased gradually, can be connected as great fire to secondarily induce short circuit and earth fault. Then analysis of heating causes of electrical connections between copper and copper alloy is needed. Also, detection and analysis algorithm of oxide at copper alloy are necessary. In this research, in order to understand the characteristics of oxide growth with rising resistance and heating, it is demonstrated that the oxide at electrical connections can cause fire due to arcing.

An Application of Non-contact IC-Card for Railway (철도에 있어서의 비접촉 IC카드 이용)

  • Park, Bong-Soon;Park, Seok-Ha;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.364-366
    • /
    • 1997
  • This paper is investigated about the IC-card being expanded gradually, and will be presented the probability applying to fare collection system of railway. To become an intelligent system for railway system, it is necessary to acquire the information for the passengers by non-contact method.

  • PDF

Performance Evaluations of a Novel Prototype of High Frequency Non-Contact Power Transformer

  • Gamage, Laknath;Ishitobi, Manabu;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.12-17
    • /
    • 2004
  • In this paper, a practical implementation to reduce leakage flux of a high-frequency inverter based non-contact type power transformer composed of EE-shape ferrite cores is presented for key technology of the next generation medical use X-ray CT scanner system. Design consideration for the unique structure of the non-contact power transformer with 900mm in diameter is also introduced. The complete non-contact transformer is actually arranged by several blocks of the magnetic circuit assembled by using 10 small EE shape cores with 120mm in length. It is experimentally and analytically discussed from a reduced leakage flux viewpoint related to its inductively coupling coefficient. A practical method to lower the leakage flux is described based on effective Copper-Sheet- Treatment placed on EE shape ferrite cores of magnetic circuit.

225[AF]/200[A]/50[kA] 배선용 차단기 고정자 변화를 통한 차단용량 향상

  • Lee, Seung-Su;Yun, Jae-Hun;Jeong, Ui-Hwan;Im, Gi-Jo;Gang, Seong-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.221-221
    • /
    • 2009
  • This paper is focused on understanding the interrupting capability, more specifically of the fix contact, based on the shape of the contact system in the current MCCB. The magnetic driving force was calculated by using the flux densities induced by the arc current, which are obtained by three-dimensional finite element method. There is a need to assure that the optimum design required to analyze the electromagnetic forces of the contact system generated by current and the flux density be present. This is paper present our computational analysis on contact system in MCCB.

  • PDF

스크린 프린팅 태양전지의 후면에 적용되기 위한 Al 특성 분석에 관한 연구

  • Lee, Jae-Du;Kim, Min-Jeong;Lee, Su-Hong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.272-272
    • /
    • 2009
  • Screen-printing metal contact is typically applied to the solar cells for mass production. And metal paste is used widely for rear contact formation of silicon solar cells. However, Screen-printing solar cell metal paste contact has low aspect ratio, low accuracy, high resistivity, hard control of unclean process. In this paper is to develop resistivity of rear contact for silicon solar cells applications. 4-point prove result, This resistivity of rear contact by Al evaporation was measured about $3.56{\times}10^6{\Omega}{\cdot}cm$ less than screen printed solar cell about $52.6{\times}10^6{\Omega}{\cdot}cm$.

  • PDF

The Dynamic Characteristics Analysis Between Pantograph and Catenary System Using Block Pulse Function (블럭펄스함수를 이용한 판토그래프와 가선시스템사이의 동특성 해석)

  • Shin, Seung-Kwon;Song, Yong-Soo;Eum, Ju-Hwan;Eum, Ki-Young
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.748-750
    • /
    • 2004
  • The pantograph should supply the electrification equipments of a train with the current from the overhead catenary system over a broad range of speeds. For a high-speed electrical train, the dynamic interaction between the pantograph and the overhead catenary system causes the variation of the contact force. As the operational speed increases, the variation of the contact force increases. The contact force variation can cause contact losses, arcing and sparking. If the spark happens between the pantograph and the overhead catenary system, the EMI(electro magnetic interface) and noises may occur. After all, the quality of current collection is deteriorated. This paper deals with the dynamic characteristics analysis between pantograph and catenary system using block pulse function.

  • PDF