• Title/Summary/Keyword: Electrical Characteristic Measurement

Search Result 367, Processing Time 0.026 seconds

Characteristic of Transport Current loss case of composition multi stacked with BSCCO wire and YBCO wire (1세대 선재와 2세대 선재의 혼합 적층시 발생하는 전송전류 손실 특성)

  • Lim, Hyoung-Woo;Cha, Guee-Soo;Lee, Ji-Kwang;Lee, Hee-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.845-846
    • /
    • 2006
  • Reduce AC loss is very important in superconductor power machine. And HTS power application are needed an increment of current capacity. in this paper estimate AC loss effect and increase of current according tocomposition stack with 1G wire and 2G wire by measurement. A Method of composition stack are YBCO-BSCCO, YBCO-BSCCO-BSCCO-YBCO and BSCCO-YBCO-YBCO-BSCCO. also, test result compared analytic equation by Norries

  • PDF

Fabrication of an Electrostatic Micro Actuator Using p+ Diaphragm As an Electrode (p+ 박막을 전극으로 한 정전형 마이크로 구동기의 제작)

  • Han, Sang-Woo;Yang, Eui-Hyeok;Yang, Sang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.141-143
    • /
    • 1994
  • In this paper, an electrostatic micro-actuator is fabricated using flat p+ diaphragm. To avoid the buckling of the flat p+ diaphragm, the processes are designed appropriately. The fabrication processes of the actuator are the anisotropic etching with EPW, the boron diffusion process, Al deposition and the silicon to glass bonding using the negative photoresist. The distance between the p+ and Al electrodes is $10{\mu}m$, and the thickness of the p+ diaphragm is $2{\mu}m$. The measurement of the characteristic of the actuator is performed at 50V. The center displacement of the diaphragm is $1.5{\mu}m$ at 10Hz. In comparison with the experimental data of the actuator with corrugated diaphragm, it is confirmed that the actuator with flat diaphragm is more effective than that with corrugated one in the small deflection region.

  • PDF

Winding Deformation Measurement using Low-voltage Impulse Tester in Transformers (변압기에서 저압충격시험기를 이용한 권선변형 측정)

  • Cho, Kook-Hee;Kang, Dong-Sik;Kim, Kwang-Hwa;Kweon, Dong-Jin;Yoon, Jin-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1737-1739
    • /
    • 1997
  • We describe the characteristic of LVI test system and methods to detect the deformation of windings in the power transformers. As the front rise time of recurrent-surge generator pulse less than 1000ns and the peak value of pulse is about 500V, we have the good results of detecting winding deformation in the LVI test of transformer. And we discuss the application of LVI test method and the condition of RSG pulse through results of in one and three pole transformers under Lab. tests.

  • PDF

Characteristic Experiment of a Hydraulic Control Valve by Using Electro-Rheological Fluid (ERF를 이용한 유압제어밸브의 특성실험)

  • Kim, Dong-Su;Park, Jae-Beom;Jang, Seong-Cheol
    • 연구논문집
    • /
    • s.30
    • /
    • pp.93-99
    • /
    • 2000
  • Electro-Rheological(ER) fluids change their apparent viscosity according to the electric field strength. The electrical and rheological properties of zeolite based the ER fluids were reported. The electric field dependent yield stress are obtained from experimental investigation on the Bingham property of the ER fluid. Using ER fluids, it is possible to directly interface between electric drop and flow rate of the ER fluid was hydraulic control valve measured under application of an electric field. The purpose of the present study is pressure drop measurement of an ER valve by using strain gage. The performance characteristics of the valve system are evalusted in terms of pressrue fixed with respect to the intensity of employed electric fields and flow rates. As a result, it is esperimentally confirmed that pressure control valve using ER fluids applicable to use in hydraulic power systems.

  • PDF

An Equivalent Circuit Model for a Dumbbell-Shaped DGS Microstrip Line

  • Woo, Duk-Jae;Lee, Taek-Kyung
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.4
    • /
    • pp.415-418
    • /
    • 2014
  • This paper presents an equivalent circuit model for a dumbbell-shaped defected ground structure (DGS) in a microstrip line. The effects of equivalent circuit elements of a dumbbell-shaped DGS and their magnetic coupling to the host transmission line are modeled as a simple lumped-element circuit. In addition, simple approximate expressions to determine the main circuit parameters for this model are presented. The transfer characteristic calculated by the proposed circuit model is compared with the results of EM simulation and measurement.

Torque measurement of Disk type Single Phase Switched Reluctance Motor (디스크형 단상 스위치드 릴럭턴스 모터의 토오크 측정)

  • Kim, Jun-Ho;Lee, Eun-Woong;Oh, Young-Woong;Kim, Sung-Jong;Woo, Sung-Bong;Lee, Min-Myung;Lee, Jong-Han
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.678-680
    • /
    • 2000
  • We designed and manufactured DSPSRM using the usual output power equation of rotating machine. And the sinusoidaly approximated torque characteristics are achieved by 3D finite element analysis. Also, We calculated average torque per rotation using approximated torque data, calculated by 3D finite element analysis. On this paper, We manufacture torque-meter set and measure the torque characteristic of DSPSRM.

  • PDF

Development of data acquisition and analysis program modules for leakage current of polymeric insulators using the Labview software (Labview를 이용한 배전용 폴리머애자의 누설전류 측정 및 분석 프로그램 개발)

  • Cho, Seong-Soo;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.1969-1971
    • /
    • 2000
  • This paper presents a data acquisition and analysis program modules that has been developed using the Labview program. These program modules can use to acquire and analyze leakage current data of insulator under different contamination conditions. The experimental hardware made up salt fog chamber, AC/DC power supply, transducer (shunt resistor), measurement devices and PC with the GPIB (General Purpose Interface Bus). And analysis program modules can calculate pulse level count, accumulated charge, average leakage current, power spectrum, and harmonics. The result of applying these analytical program modules to polymeric insulator is available for evaluation of leakage current characteristic of outdoor insulators.

  • PDF

Experimental Characteristic Analysis of Induction Watthour Meter by Input Source with Harmonics (고조파 함유전원에 의한 유도형 적산전력량계의 실험적 특성해석)

  • Jang, Seok-Myeong;Lee, Sung-Ho;Park, Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.58-60
    • /
    • 1998
  • The precise measurement of consumed power during the given time is very important in the energy management aspect. Up to days, induction watthour meter has been designed for use in the alternating circuits in which the voltage and current are essentially sinusoidal. The use of switching elements in power system causes the current or voltage involving harmonics. Therefore the registration error is caused by harmonics in the equipment for measuring power. This paper presents the registration error of the induction watthour meter in the presence of harmonic distortion. The accuracy of a watthour meter on loads in which the input source is not sinusoidal is investigated. And the effects of individual harmonic are reported by experiment.

  • PDF

Impedance measurement and analysis of overhead medium voltage power lines for broad band power line communication (BPLC) ($1{\sim}30MHz$ 광대역 전력선 통신을 위한 고압 배전선의 임피던스 특성 측정 및 해석)

  • Park, Young-Jin;Lee, Jae-Jo;Kim, Kwan-Ho;Lee, Won-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2345-2347
    • /
    • 2005
  • In this paper, impedance characteristics of overhead medium-voltage (MV) power lines is reported for power line communication (PLC) over an MV power line network. For analysis, a two-port equivalent network model of MV power lines is derived. By applying the transmission line theory, reflection behavior and impedance of power lines are investigated. For verification, impedance of power lines is measured at a test field for an MV PLC. The results show that impedance of MV power lines is between $200{\Omega}$ and $300{\Omega}$ and converges to a half of their characteristic impedance.

  • PDF

Characteristic research of the Chalcogenide thin film for 2-Dimensional photonic crystal formation (2차원 광결정 형성을 위한 칼코게나이드 박막의 특성 연구)

  • Nam, Ki-Hyeon;Ju, Long-Yun;Kim, Hyun-Koo;Chung, Hong-Bay
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.134-135
    • /
    • 2007
  • Two-dimensional photonic crystal structures have been fabricated on the chalcogenide material using holography lithography out of many production technical. The fabricated lattice can be observed obliquely by measuring diffraction pattern. The diffraction pattern of the microstructure has been observed with a He-Ne laser beam at wavelength of 632.8 nm. The diffracted beam has been analyzed by using the diffraction efficiency measurement method.

  • PDF