• 제목/요약/키워드: Electrical Characteristic Measurement

검색결과 367건 처리시간 0.056초

교통환경 정온화를 위한 도로 소음의 측정 및 ANC시스템에의 적용 특성 고찰 (A Study on the Characteristics of Applicability in the Active Noise Cancellation System and Measurement of the Road Noise for Traffic Calming)

  • 문학룡;손진근
    • 전기학회논문지P
    • /
    • 제62권3호
    • /
    • pp.111-116
    • /
    • 2013
  • Noise problem that occurs on the road is raising a lot of problems in the economic, social and environmental aspects. The objective of this paper is to propose ANC(active noise cancellation)-based road traffic noise reduction algorithm-model which can reduce noise by generating frequency opposed to noise sources to improve and complement the problem that existing physical form of a noise barrier. In this paper, we measured the noise characteristic from collection of two difference car noise also ANC simulation has been performed by using road traffic noises input. In order to compare the control performance, we performed noise reduction simulation of ANC by filtered-X LMS algorithm and delayed control signal injection. As a result of this simulation, we confirmed that convergence performance and noise decrease effect to the filtered-X LMS algorithm by inputting the road traffic noise.

디지털 신호처리기를 이용한 고분해능 온도측정 시스템 설계 (A Design of High Resolution Temperature Measurement System Using Digital Signal Processor)

  • 김태훈;임주현;김덕영;고한우;김성환
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권7호
    • /
    • pp.317-322
    • /
    • 2002
  • This paper presents a linear temperature/voltage relation over a temperature range(0~100$^{\circ}C$) with high-resolution, reasonably god response linearity, reliability, and overall improved performance. A notable feature of the proposed method is that the whole temperature span is divided by 16 subbands thus the variation span of measured voltage is narrowed. Therefore noise characteristic has been improved. The output voltage is amplified after the uniformed DC voltage component is eliminated by offset. We proposed circuit using median value and mean value of digital signal in order to reduce the noise effect. The proposed circuit offers linear temperature/voltage conversion over a wide dynamic range using DSP(TMS320C31) and steinhart equation.

신경회로망을 이용한 GIS용 단로기의 이상신호 패턴분석 (The Analysis of trouble signal on DS for GIS using Neural Network)

  • 김종서;박용필;천종철;이은석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1196-1199
    • /
    • 2003
  • Recently, the development of diagnosis technique with high confidence is important on power equipment, for this reason is use for measurement and analysis of PD with prior appearance of insulation breakdown. In this paper, we presents the analysis of trouble signal to use ${\phi}-Q$ method which display 2D and 3D Equipment of simulation has made independently DS for 170kV GIS of one phase with same on field. The detected signal through the sensor of Induction and Acoustic Emission is classified to use characteristic neural network algorithm and then it is analysis.

  • PDF

기중방전 진전에 따른 방사전자파의 주파수 스펙트롬 특성 (The Characteristic of Frequency Spectrum of Electromagnetic Waves Radiated from Discharge in Air)

  • 박광서;윤대희;박창기;주재현;최병주;이광식;이동인
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1999년도 학술대회논문집-국제 전기방전 및 플라즈마 심포지엄 Proceedings of 1999 KIIEE Annual Conference-International Symposium of Electrical Discharge and Plasma
    • /
    • pp.285-289
    • /
    • 1999
  • Insulation diagnosis techniques of power equipments for the stable power supply and prevention from accidents are of high importance. Diagnosis techniques is able to prevent from large accidents before they happen by finding signs of the accidents. From this point of view, this paper simulated discharge progress and partial discharge using needle-plan electrode system in air, studied the distribution of frequency spectrum of the radiated electromagnetic waves using biconical antenna and spectrum analyzer. From results of this study, the new method was introduced for measurement and analyzation of the radiated electromagnetic waves in accordance with discharge progress in air, Besides, according to the consideration of the mutual relation between frequency spectrum of the radiated electromagnetic waves and discharge progress, it was confirmed that detecting partial discharge and estimating discharge progress were possible.

  • PDF

개선된 수렴 특성을 갖는 적응 극배치 제어기의 설계에 관한 연구 (A Study on the Design of an Adaptive pole Placement Controller with Improved Convergence Properties)

  • 홍연찬;김종환
    • 대한전기학회논문지
    • /
    • 제41권3호
    • /
    • pp.311-319
    • /
    • 1992
  • In this paper, a direct adaptive pole placement controller for an unknown linear time-invariant single-input single-output nonminimum phase plant is proposed. To design this direct adaptive pole placement controller, the auxiliary signals are introduced. Consequently, a linear equation error model is formulated for estimating both the controller parameters and the additional auxiliary parameters. To estimate the controller parameters and the additional auxiliary parameters, the exponentially weighted least-squares algorithm is implemented, and a method of selecting the characteristic polynomials of the sensitivity function filters is proposed. In this method, all the past measurement data are weighted exponentially. A series of simulations for a nonminimum phase plant is presented to illustrate some features of both the parameter estimation and the output response of this adaptive pole placement controller.

  • PDF

ZnO 피뢰기의 경년변화 특성분석 (Aging Characteristics of ZnO Surge Arresters)

  • 김주용;김찬영;송일근;이병성;한용희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.383-386
    • /
    • 1999
  • Surge arrestor is used for protection of facilities and lines. Recently lots of arresters fatted prematurely In the distribution lines. It is important to know that what the cause of the failures is. This paper presents characteristics of the aged and new 18kV surge arrester. In order to analyse characteristics, we measured leakage current using specialty made leakage current measurement system and also investigated Tan $\delta$ of the arrester and microstructure of the elements. Through the investigation we found that the characteristics among the ZnO elements in an arrester were a little different, It means that the surge arreste can have non-uniform electric field due to the characteristic difference of The each element. Owing to this concentration of the electric field, the localized aging might be proceeded.

  • PDF

하이브리드 방식에 의한 미시적 부하모델링 (Component-Based Load Modeling Updated by Hybrid Technique)

  • 지평식
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권3호
    • /
    • pp.179-182
    • /
    • 2003
  • Component-based method for load model not only should include the performances of the load components, but also should take into consideration the core losses of transformers, the line losses and the capacitor banks. Especially, capacitor bank affects the accuracy of reactive load model in load modeling. But it is difficult to identify actual reactive powers of capacitor banks in power system for load modeling. This research improves the component-based modeling method including uncertain capacitor bank. The proposed method is hybrid technique, which adds the measurement-based method to the existing component-based method for reliable information of capacitor band. The results of case studies were presented to verify the validity of the proposed method.

웨이블렛 변환을 이용한 부분 방전 신호 분석 (An Analysis of Partial Discharge signal Using Wavelet Transforms)

  • 박재준;장진강;임윤석;심종탁;김재환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.169-172
    • /
    • 1999
  • Recently, the wavelet transform has been a new and powerful tool for signal processing. It is more suitable specially for the feature extraction and detection of non-stationary signals than traditional methods such as, the Fourier Transform(FT), the Fast Fourier Transform(FFT) and the Least Square Method etc. because of the characteristic of the multi-scale analysis and time-frequency domain localization. The wavelet transform has been developed for the analysis of PD pulse signal to raise in the progress of insulation degradation. In this paper, the wavelet transform was applied to one foundational method for feature extraction. For the obtain experimental data, a computer-aided partial discharge measurement system with a single acoustic sensor was used. If we are applying to the neural network method the accumulated data through the extracted feature, it is expected that we can detect the PD pulse signal in the insulation materials on the on-line.

  • PDF

컴퓨터 시뮬레이션에 의한 일렉트렛트 센서의 최적 전계 해석과 응용 (A Study of Optimum Electromagnetic Field Analysis and Application of the Electret Sensor Using Computer Simulation)

  • 정동회;김상걸;김성렬;김용주;김영천;이준웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.435-438
    • /
    • 1998
  • In this paper, Electret is formed to range voltage -5[kV] to -8[kV] by corona charging in PTFE film and sensor is manufactured by method of moments in sensing infra sonic. Charges of charged film are calculated also TSC measurement and induced potential of sensing electrode according to the charges is become aware of computer simulation. Electret Infra Sonic Transducer, which is designed and manufactured according to the potential and electric field simulation in using method of moments, is proved as it is effectively. Because sensitivity that measured under 10[Hz] is that average value of sensitivity rising rate is 6.34 [dB/oct] as average value is $\pm$1 [dB/oct] range -5[kV] to -8[kV] in corona charging film. As a result, it is believed that characteristic of acquired transducer can be application of medical treatment, industry, and animal life researches and the study of noise elimination, what's more, is required.

  • PDF

ac PDP에서의 Reset과 Address 구간에서 Negative Waveform특성에 관한 연구 (A Study of Negative Waveform in ac PDP during Reset and Address Periods)

  • 엄철환;강정원
    • 반도체디스플레이기술학회지
    • /
    • 제8권1호
    • /
    • pp.27-31
    • /
    • 2009
  • A characteristic of new waveform, called a negative waveform, was studied during reset and address periods. IR distribution, black luminance and time delay were measured to compare the negative waveform with the conventional positive waveform. Based on the analysis of IR measurement, the negative waveform could accumulate more wall charges than the positive waveform. Also the black luminance of negative waveform was lower than that of positive waveform under the same bias and ramp-slope conditions. During address period, the discharge time lag was measured. The negative waveform was showed 0.25 us faster formative time lag and 0.1 us faster average time lag than those of positive waveform.

  • PDF