• 제목/요약/키워드: Electrical Accident

검색결과 519건 처리시간 0.049초

고전압설비에서 발생하는 부분방전 검출용 전계센서의 설계 및 특성 검토 (Design and Application of Electric Field Sensor for Measuring PD Signals in High Voltage Equipments)

  • 이강원;강성화;임기조
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권10호
    • /
    • pp.431-435
    • /
    • 2003
  • It is very difficult and dangerous to measure PD(Partial Discharges) from high voltage equipments in outdoor situation. But that is very important thing for preventing them from more serious accident by defects made by insulating degradation. This paper provides useful method to detect PD signals easily without any dangerous situation. Electric field sensor by the principle of capacitor can detect PD signals without direct connection between sensor and high voltage equipment and has very wide frequency range suitable for noise rejection. Electric field sensor and related circuit for processing PD signal show good performance as a PD sensor when it is applied to simulated high power equipment generating PD pulses.

송전용 자기재 애자의 열화시험 평가기술 (Assessment Technique and Aging Test for EHV Porcelain Insulators)

  • 한세원;조한구;박기호;정길조;이동일;최인혁;신태우
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.480-483
    • /
    • 2002
  • This paper through shift norm of insulator and research by accident prevention countermeasure special skill authoritativeness verification of insulator and Long Term aging factor for power transmission analysis and evaluate and prove quality of insulator wish to. Assessment technique by aging of own porcelain insulator observes ageing factor for reciprocity comparison through several examinations. Through cool and heat accelerated Aging test, can measure the leakage current change amount that ensue to each Cycle. Can confirm own blazing fire factor as distribution freshness that ensue in HRB Test's hardness value.

  • PDF

Analysis of Two Electrocution Accidents in Greece that Occurred due to Unexpected Re-energization of Power Lines

  • Baka, Aikaterini D.;Uzunoglu, Nikolaos K.
    • Safety and Health at Work
    • /
    • 제5권3호
    • /
    • pp.158-160
    • /
    • 2014
  • Investigation and analysis of accidents are critical elements of safety management. The over-riding purpose of an organization in carrying out an accident investigation is to prevent similar accidents, as well as seek a general improvement in the management of health and safety. Hundreds of workers have suffered injuries while installing, maintaining, or servicing machinery and equipment due to sudden re-energization of power lines. This study presents and analyzes two electrical accidents (1 fatal injury and 1 serious injury) that occurred because the power supply was reconnected inadvertently or by mistake.

건전지의 방전에 의한 폭발성 가스의 점화에 관한 실험적 연구 (Experimental Study on Ignition of Flammable Gas by Spark of Dry Battery)

  • 이춘하;송현직;이광식;이동인
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1543-1546
    • /
    • 1994
  • Ignitabilility of explosive gas mixture by spark of dry cell in case of short circuit by accident was studied for the purpose of evaluation of intrinsically safe characteristics of dry cell that manufactured in Korea. IEC type spark test apparatus, $21{\pm}2$ Vol% of hydrogen - air mixture, and dry cell that produced in Korea was used for the experiment. The result of this research could be used for design, manufacturing, and using the intrinsically safe electrical apparatus.

  • PDF

전기철도 급전계통의 집전전압 안정도 해석 (Analysis of Voltage Stability in Electric Railway Feeding System)

  • 이장무;이한민;한문섭;김주락;정호성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1384-1389
    • /
    • 2004
  • The primary objective of this paper is to examine the capacity of electrical transmission in electric railway feeding system. Although supply capacity of railway substation are sufficient and there is no accident, due to the electrical transmission limit of feeding line the voltage breakdown may occur when large capacity of electric load at feeding line exist. So, using multi-port analysis model, we draw P-V curve due to the length of feeding line, load, location and power factor of electric locomotive. And through case study, compare measurement result and simulation result

  • PDF

움직임 물체 검출 기반 학원 통학차량 승하차 위험 경고 시스템 (Motion Object Detection Based Hagwon-Bus Boarding Danger Warning System)

  • 송영철;박성령;양승한
    • 전기학회논문지
    • /
    • 제63권6호
    • /
    • pp.810-812
    • /
    • 2014
  • In this paper, a hagwon-bus boarding danger warning system based on computer vision is proposed to protect children from an accident causing injuries or death. Three zones are defined and different algorithms are applied to detect moving objects. In zone 1, a block-based entropy value is calculated using the absolute difference image generated by the absolute differential estimation between background image and incoming video frame. In zone 2, an effective and robust motion object tracking algorithm is performed based on the particle filter. Experimental results demonstrate the efficient and effectively of the algorithm for moving object inspection in each zone.

패리티공간기법과 신경회로망을 이용한 원전 공정변수 추정 (Estimation of the Process Variable for Nuclear Power Plants Using the Parity Space Method and the Neural Network)

  • 오성헌;김대일;김건중
    • 대한전기학회논문지
    • /
    • 제43권7호
    • /
    • pp.1169-1177
    • /
    • 1994
  • The function estimation characteristics of neural networks can be used sensor signal estimation of the nuclear power plants. In case of applying the neural network to the signal estimation of redundant sensors, it is an important problem that the redundant sensor signals used as the input signals of neural network should be validated. In this paper, we simplify the conventional parity space method in order to input the validated signal to the neural network and lso propose the sensor signal validation method, which estimates the reliable sensor output combining the neural network with the simplified parity space method. The acceptability of the proposed process variable estimation method is demonstrated by using the simulation data in safety injection accident of the nuclear power plant.

고초파 장해기기의 저감 대책의 변화에 관한 연구 (A Study on Variation of Counterplan in Harmonics Interference Equipment)

  • 성은하;오무송;이은학;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.414-417
    • /
    • 1999
  • According to development of power electric technology from industrial field to electronic home appliances, recent SMPS using semiconductor is spread widely. Electric converting instrument uses a sine wave voltage source, namely an usual power source, and it gets a non-sines power source from power source because current flows through one part in waveform of one cycle. This injects higher harmonic source in source part, absorb pollution source. And this cause quality deterioration, durability shortage of electric power instrument, spreading accident of electric solver system, and so on. It can't supply an electric source of good quality in industry, so become an impedimental element in improving productivity and reliance. This study can be used in prediction of hindrance and diagnosis material and intends to suggest a countermeasure about measurement data.

  • PDF

차세대원전 안전등급모선의 전원공급 다중성 연구 (Study on the Diversity of Power supply to Safety related Bus in Korean Next Gener)

  • 윤정현;지문구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.1170-1172
    • /
    • 1998
  • The electrical power of nuclear power plant consists of Safety related power systems and Non-Safety related power systems. The safety related power systems are designed to have sufficient capacity to safely shut down the unit and to mitigate the effects of an accident assuming loss of off-site power. This paper presents the operation scheme of the safety related power system for several plant conditions in Korean Next Generation Reactor and reviews the diversity of power supply to the safety related bus.

  • PDF

컴퓨터기반 철도신호제어시스템의 안전성 확보에 관한 연구 (A Study on Safety for Computer Based Railway Signaling Control System)

  • 신덕호;이종우
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권11호
    • /
    • pp.641-646
    • /
    • 2004
  • Computer system is widely used for controlling systems such as nuclear power plant, train speed control and air plane control. The failure of computerized controlling system can be arrived to catastrophic accident, so the safety ensuring of computerized controlling system is very important. This paper shows how to improve and ensure the safety of computerized systems. In this paper, we show how to identify, analyze hazards of the computerized system and to demonstrate risk of the system. Finally, we show how to adopt safety techniques for improving safety of the target system.