• Title/Summary/Keyword: Electric-Vehicles

Search Result 1,400, Processing Time 0.025 seconds

An Investigation of EMI Reduction Technique using the Spread Spectrum for an Automotive Power Converter (EMI 개선을 위해 자동차용 전력변환기에 적용된 주파수 확산 기법 분석)

  • Chae, Gyoo-Soo
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.2
    • /
    • pp.1-6
    • /
    • 2018
  • In this study, the investigation results of conducted and radiated emission for DC/DC converter circuit applied in electric vehicles are presented. A frequency spreading circuit was used to improve the EMI characteristics of a power converter designed by using MPQ4433 chip. The frequency spreading circuit using a TLV3201 chip was designed and applied to the power converter. A PCB was fabricated based on the EMI minimization procedures and simulated and measured results were presented for the far-field and near-field conducted and radiated emissions using the fabricated circuit. The measurement were done as CISPR 25 standardized test procedures. It is clearly showed that the EMI characteristics were improved 20% in case frequency spreading was applied. The EMI reduction technique using the frequency spreading proposed in this study was first applied to the design of power converter module for automobile. It is expected that the method presented here can be effectively used for EMI improvement in the future.

A Study on Generalized Output Capacitor Ripple Current Equation of Interleaved Boost Converter (인터리브드 부스트 컨버터에 대한 일반화된 출력 커패시터 리플전류 수식에 관한 연구)

  • Jung, Yong-Chae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.6
    • /
    • pp.1429-1435
    • /
    • 2012
  • DC-DC converter commonly used in photovoltaic systems, fuel cell systems and electric vehicles is a boost converter. The interleaved boost converter, connected in parallel by several boost converters and operated by the phase difference to reduce the input and output current ripple, has been widely used in recent years. Because of small input and output current ripples, the circuit can reduce the size of the input and output capacitors. Thus, instead of conventional electrolytic capacitor, the film capacitor with high reliability can be used and this is the life and reliability of the entire system can be improved. In this paper, the output current ripple formulas of the multi-stage interleaved boost converter are derived, and the characteristics in accordance with duty are found out. In order to verify the abovementioned contents, the derived results will make a comparison with the calculated values by using PSIM tool.

Recent advances in Studies of the Activity of Non-precious Metal Catalysts for the Oxygen Reduction Reaction in Polymer Electrolyte Membrane Fuel Cells (고분자 전해질 연료전지용 산소환원반응을 위한 비백금촉매의 활성에 대한 최신 연구 동향)

  • Yoon, Ho-Seok;Jung, Won Suk;Choe, Myeong-Ho
    • Journal of the Korean Electrochemical Society
    • /
    • v.23 no.4
    • /
    • pp.90-96
    • /
    • 2020
  • Polymer electrolyte membrane fuel cells, which convert the chemical reaction energy of hydrogen into electric power directly, are a type of eco-friendly power for future vehicles. Due to the sluggish oxygen reduction reaction and costly Pt catalyst in the cathode, the research related to the replacement of Pt-based catalysts has been vitally carried out. In this case, however, the performance is significantly different from each other and a variety of factors have existed. In this review paper, we rearrange and summarize relevant papers published within 5 years approximately. The selection of precursors, synthesis method, and co-catalyst are represented as a core factor, while the necessity of research for the further enhancement of activity may be raised. It can be anticipated to contribute to the replacement of precious metal catalysts in the various fields of study. The final objective of the future research is depicted in detail.

Development and Demonstration of 150W Fuel Cell Propulsion System for Unmanned Aerial Vehicle (UAV) (무인항공기용 150W급 연료전지 동력원 개발 및 실증)

  • Yang, Cheol-Nam;Kim, Yang-Do
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.4
    • /
    • pp.300-309
    • /
    • 2012
  • Long endurance is a key issue in the application of unmanned aerial vehicles. This study presents feasibility test results when fuel cell system as an alternative to the conventional engine is applied for the power of the UAV after the 150W fuel cell system is developed and packaged to the 1/4 scale super cub airplane. Fuel cell system is operated by dead-end method in the anode part and periodically purged to remove the water droplet in flow field during the operation. Oxygen in the air is supplied to the stack by the two air blowers. And fuel cell stack is water cooled by cooling circuit to dissipate the heat generated during the fuel cell operation. Weight balance is considered to integrate the stack and balance of plant (BOP) in package layout. In flight performance test, we demonstrated 4 times standalone take-off and landing. In the laboratory test simulating the flight condition to quantify the energy flow, the system is analyzed in detail. Sankey diagram shows that electric efficiency of the fuel cell system is 39.2%, heat loss 50.1%, parasitic loss 8.96%, and unreacted purged gas 1.67%, respectively compared to the total hydrogen input energy. Feasibility test results show that fuel cell system is high efficient and appropriate for the power of UAV.

A Study on Monitoring System Architecture for Calculation of Practical Recycling Rate of End of Life Vehicle (폐자동차의 실질적 재활용률 산정을 위한 모니터링 체계에 관한 연구)

  • Park, Jung Whan;Yi, Hwa-Cho;Park, Myon Woong;Sohn, Young Tae
    • Clean Technology
    • /
    • v.18 no.4
    • /
    • pp.373-378
    • /
    • 2012
  • The end-of-life vehicles (ELV) are important recycling sources, and there are several stages involved in the recycling such as dismantling, shredding, and treatment of shredder residues (ASR). The legal recycling rate should be at least 95% on and after 2015, while we need a proper system to monitor recycling of ELV components and to calculate the practical recycling rate. The paper suggests a monitoring system that calculates practical recycling rates of dismantled components by use of a database of standard recycling rate as well as a web-based monitoring, which is linked to the Eco Assurance system for electric & electronic equipment and vehicle (EcoAS). Also the system supports dismantling and monitoring process by incorporating a standard vehicular component database, which facilitates recording dismantled weight data but also monitoring of dismantled components.

A Study on IoT Monitering Technology of Power Converter for E-Mobility (E-Mobility용 전력변환기의 IoT 모니터링 기술에 대한 연구)

  • Lee, In-Seok;Lee, Ju;Kang, Ja-Yoon
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.3
    • /
    • pp.39-44
    • /
    • 2018
  • In this paper, we propose a monitoring method of smartphone to integrate IoT technology to monitor the state of the vehicle for fault diagnosis of E-Mobility power converter. In China, EV regulations are being implemented to promote technological development and market changes in electric vehicles. To meet this trend, E-Mobility should study suitable monitoring technology. The OBD-II method used in existing automobiles is a wired / wireless communication method. In order to apply it to E-Mobility, additional interface and communication link are required. In this paper, we propose a technology to monitor the status information of power converter for E-Mobility by combining existing technology with IoT. This technology simplifies the existing network protocol and hardware interface, and confirms that the E-Mobility power converter and smartphone can be interworked for easy user monitoring. And we have done research to make high value product design from the aspect of function.

Performance Characteristics of the Electrical Air Conditioning System for the Zero Emission Passenger Vehicle (무공해 승용 자동차의 냉방을 위한 전동식 냉방시스템 성능에 관한 연구)

  • Lee, Moo-Yeon;Cho, Chung-Won;Lee, Ho-Seong;Won, Jong-Phil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.12
    • /
    • pp.5430-5437
    • /
    • 2011
  • The objective of this study is to investigate the cooling performances of the electrical air-conditioning system using electric driven scroll compressor for zero emission passenger vehicles. This air conditioner with air source was used R-134a as a refrigerant and installed in a real zero emission passenger vehicle for tests under various driving conditions. The cooling performance of the electrical air conditioner was affected by driving velocities and conditions of the tested vehicle. The condensing rate of the condenser during driving is better than that of the idle condition. The average cool down temperature in the cabin room decreased on average $5.2^{\circ}C$ with the increase of the outdoor temperature from $20.0^{\circ}C$ to $30.0^{\circ}C$. In addition, the cooling performances were sufficient for cooling loads of the tested passenger car under tested conditions.

The Trend of System Level Thermal Management Technology Development for Aero-Vehicles (항공기 시스템 레벨 열관리 기술개발 동향)

  • Kim, Youngjin;Son, Changmin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.35-42
    • /
    • 2016
  • Modern aircraft is facing the increase of power demands and thermal challenges. In accordance with the application of more electric technology and advanced mission requirement, aircraft system requires increase of power generation and it cause increase of internal heat generation. Simultaneously, restrictions have significantly been imposed to the thermal management system. Modern aircraft must maintain low radar observability and infra-red signature. In addition, new composite aircraft skins have reduced the amount of heat that can be rejected to the environment. The combination of these characteristics has increased the challenges faced by thermal management. In order to mitigate the thermal challenges, the concept of system level thermal management should be applied and new modeling and simulation tools need to be developed. To develop and utilize system level thermal management technology, three key points are considered. Firstly, the performance changes of subsystems and components must be assessed at an integrated thermal system. It is because that each subsystem and component interacts with other subsystems or components and it can directly effects on overall system performance. Secondly, system level thermal management requirements and solutions must be evaluated early in conceptual design process as vehicle and propulsion system configuration decisions are being made. Finally, new component level thermal management technologies must focus on reducing heat generation and increasing the availability of heat sinks.

Electrochemical Characteristics of all solid supercapacitor based on DAAQ(1,5-diaminoanthraquinone) and SPEEK(sulfonated polyether ether ketone) (DAAQ와 SPEEK를 이용한 전고상 슈퍼커패시터의 전기화학적 특성)

  • Kim, Jin-Yong;Kim, Hong-Il;Kim, Han-Joo;Park, Soo-Gil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.371-372
    • /
    • 2005
  • Supercapacitors are promising devices for delivering high power density. Digital communications, electric vehicles and other devices that require electrical energy at high power levels in relatively short pulses have prompted considerable research on supercapacitors. In recent years, solid electrolytes have been investigated for supercapacitors. Solid electrolytes are advantageous over liquid electrolytes in respect of easy handling and reliability without electrolyte leakage. In this preliminary study, an electrochemical supercapacitor in all solid configuration has been fabricated using CNF-DAAQ and poly-vinylidenefluoride(PVdF). A new type of Supercapacitor was constructed by using carbon nanofibers(CNFs) and DAAQ(l,5-diaminoanthraquinone) monomer. DAAQ was deposited on the carbon nanofibers by chemical polymerization with $(NH_4)_2S_2O_8$ as oxidant in the 0.1M $H_2SO_4$. Dried SPEEK powder was mixed with N-methyl pyrrolidone to make 10 wt.% solution in an ultrasonic bath, the slurry was cast over a glass substrate heated to $70^{\circ}C$ for solvent evaporation. And then we used solid electrolyte of SPEEK. The unit cell consist of DAAQ-CNF/electrolyte/Pt. From the analysis, it is clear that surface of carbon nanofibers was quite uniformly coated with DAAQ. The performance characteristics of the supercapacitors have been evaluated using Cyclic Voltammetry.

  • PDF

A Study on the Performance Characteristics of a Heat Pump System using Stack Wast Heat in Fuel Cell Vehicles (스택 폐열을 이용한 연료전지 자동차용 열펌프 시스템의 성능 특성에 관한 연구)

  • Jeon, Byungyong;Ko, Wonbin;Park, Youn Cheol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.8
    • /
    • pp.325-330
    • /
    • 2016
  • This study was conducted to develop a heating system for a fuel cell-driven electric vehicle. The system consists of a compressor, an expansion device and three heat exchangers. A conventional air source heat exchanger is used as primary heat exchanger of the system, and an additional water source heat exchanger is used as a pre-heater to supply heat to the upstream air of the primary heat exchanger. On the other hand, the third heat exchanger consists of a water-to-refrigerant heat exchanger. The heat source of the pre-heater and the water-refrigerant heat exchanger is the waste heat from the fuel cell's stack. In the experiment, the indoor and the outdoor air temperature were fixed, and the compressor speed, EEV opening and waste heat temperature were varied. The results indicate that the $COP_h$ of the proposed system is 3.01 when the system is operating at a 1,200 rpm compressor speed, 50% EEV opening, and $50^{\circ}C$ waste heat source temperature in air pre-heater operation. However, when the system uses a water-refrigerant heat exchanger, the $COP_h$ increases to up to 9.42 at the same compressor speed and waste heat source temperature with 75% EEV openings.