• Title/Summary/Keyword: Electric pump

Search Result 375, Processing Time 0.023 seconds

A Study on Design of Notches in Valve Plate of Swash Plate Type Axial Piston Pumps Operated Bi-directionally (양방향 구동 사판식 액시얼 피스톤 펌프의 밸브 플레이트 노치 설계에 관한 연구)

  • Choi, Sae Ryung;Lee, Ill Yeong;Han, Sung Min;Shin, Jung Woo
    • Journal of Drive and Control
    • /
    • v.13 no.3
    • /
    • pp.39-46
    • /
    • 2016
  • Flow and pressure ripple in swash plate type piston pumps is largely dependent on the design of notches(silencing grooves) in the valve plate. In uni-directional pumps, the basic design concept for notches in the valve plate could be said to be established. It is easily deduced that the design concept for notches in uni-directional pumps can not be simply applied to bi-directional pumps requested for EHA(electric hydrostatic actuators). To carry out systematic research on technological issues regarding notch applications to bi-directional piston pumps, five notch designs are devised. The effects of the notch designs on the characteristics of the pump are investigated by numerical simulations and experiments. Through this study, basic concepts about notch design for bi-directional piston pumps are suggested.

Study on the Operational Cost and Characteristics of a Hybrid Cooling Plant with a Ground Source Heat Pump (지열 열펌프가 적용된 복합냉방설비의 연계운전 특성 및 운전비용 분석)

  • Jeon, Jong-Ug;Jung, Hae-Won;Lee, Tae-Won;Kim, Yong-Ki;Hong, Dae-Hie;Kim, Yong-Chan
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.42-47
    • /
    • 2008
  • This paper reports the system performance of a hybrid plant, which combines a renewable energy plant of GSHP(Ground Source Heat Pump) with a conventional plant (screw water chiller). To find out operational cost and operating characteristics, the performance of the hybrid system was measured in a building located in Jeju island. Based on the measured data, the operating characteristics were analyzed and the operational cost was estimated by using payment table, which was provided by the Korea Electric Power Cooperation. Operating methods to save energy were recommended.

  • PDF

A Study on the Flow Characteristic for Changing of Flow Region of the Motor Inserted Oil Pump (내부 유로 변경에 따른 전동기 일체형 유압펌프 내부의 유동특성에 관한 연구)

  • Choi, Y.H.;Lee, T.K.;Lee, Y.W.
    • Journal of Power System Engineering
    • /
    • v.16 no.5
    • /
    • pp.26-31
    • /
    • 2012
  • A numerical study has been carried out to investigate the heat and mass transfer of an oil pumping system with a variable shape of the housing using the CFD method. Especially, the electric motor and the pump combined together, accomplishes a research about the oil supplying system. In this study, the temperature and velocity distribution of the oil pumping system by varying the flow rate of supplying oil have been investigated. The temperature changes with each five conditions(flow rate of supply oil : 2, 4, 8, 12, and 16 liter/min) have also been studied. The numerical results show that the exhaust temperature decreases as the flow rate of the supplying oil increases. It also reveals that the temperatures change differently with the housing shape.

A Study on the Optimization of Heating and Cooling System in University Campus (대학 캠퍼스 냉·난방시스템 최적화 방안 연구)

  • Park, So-Yeon;Park, Hyo-Soon;Lee, Sang-Hyeok;Kim, Ji-Yeon;Hong, Sung-Hee
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.139-144
    • /
    • 2010
  • The demands are increasing for the efficient heating and cooling system and thermal comfort environment because of changes in climate and environment, and deterioration of buildings and facilities can cause education budget to increase. So the study to apply heating and cooling system to university is urgently needed to improve an optimum energy saving system, educational environment and convenience of maintenance. For this reason, we selected a university campus in Seoul then came to understand the current situation and found some problems. We drew alternatives from comparative analysis of them. It selects representative building and carries out economic analysis to evaluate characteristics of energy consumption and economics on each type of heating and cooling system. As a result we drew the optimum system from those processes as previously stated. We studied 3 available systems, absorption chiller, EHP(Electric Heat Pump) and GHP(Gas Engine Heat Pump). According to LCC analysis suppose that the value of EHP is 1, it came out that the value of absorption chiller is 1.5 and the value of GHP is 2.2. This study, suggesting the optimum heating and cooling system, will support educational and research activities furthermore effect to maximize energy efficiency. Ultimately it is expected that it will contribute to make eco-friendly Green Campus.

Temperature Setpoint Algorithm for the Cooling System of a Tilting Train Main Transformer (틸팅열차 주변압기 냉각시스템의 온도설정알고리즘)

  • Han, Do-Young;Noh, Hee-Jeon;Won, Jae-Young
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.387-392
    • /
    • 2008
  • In order to improve the efficiency of the main transformer in a tilting train, the optimal operation of a cooling system is necessary. For the development of the optimal control algorithm of a cooling system, the mathematical model of a main transformer cooling system was developed. This includes the dynamic model of a main transformer, an oil pump, an oil cooler and a blower. The system algorithm of a cooling system, which consists of the temperature setpoint algorithm and the temperature control algorithm, was developed. Optimal oil temperatures of the inlet and the outlet of the main transformer were obtained by considering the total electric power consumption of the system. The oil inlet temperature was controlled by the blower and the oil outlet temperature was controlled by the oil pump. A simulation program was developed by using the mathematical model and the system algorithm. Simulation results showed that the system algorithm developed from this study may be effectively used to control the main transformer cooling system in a tilting train.

  • PDF

Performance Analysis of an Electro-Hydrostatic Actuator (Electro-Hydrostatic Actuator의 성능해석)

  • Kim, Do-Hyun;Kim, Doo-Man;Hong, Yeh-Sun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.4
    • /
    • pp.316-322
    • /
    • 2007
  • The EHA(Electro-hydrostatic Actuator) reveals completely different characteristics from the conventional valve-controlled Electro-hydraulic actuators. In this paper, its mathematical model including nonlinear elements was derived to be verified by experiments. Based on this, a simulation program was developed for the EHAs consisting of an electric motor driven hydraulic pump, pipe lines and a cylinder. The influence of important design parameters such as peak motor torque and rotational inertia moment of the hydraulic pump on control performance was investigated, where the test condition was intentionally selected so that the motor torque was saturated during the transient phase. As a result, design requirements for improving the control accuracy under full speed operation conditions of the EHAs were investigated.

Development of Heating and Cooling System with New Heat Exchange Cycle for High Efficiency and Peak Power Reduction Using Real time Constant Refrigerant Pressure Control (실시간 일정압력 제어기술을 적용한 냉난방장치의 피크부하 저감과 에너지 효율 향상을 위한 시스템 개발)

  • Choi, Sun-Young;Lee, Young-Kug;Choi, Myeong-Gwang;Choi, Tae-Won
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.53-58
    • /
    • 2015
  • Systemic heating and cooling air conditioning systems are popular in various industrial fields and even home. Recently, the rate of supply of this kind of multi-heat pump has been increased under ESCO financing supporting system. Generally the heat pumping system has a structural simplicity and easy installation benefits. and has good running efficiency under normal designed condition. But under extreme climate condition (over $+30^{\circ}C$, under $-10^{\circ}C$), this system exposes abnormal power consumption. It causes high progressive electric power rates and resultant peak power capacity of power plant. In this paper, a novel system concept of buffering refrigerant accumulator and constant pressure control system to relieve peak power load is proposed and this system's utility is verified with an prototype experimental system.

Experimental Quality Characteristics for Water Removal in Inner Flushing Oil in Process Piping of Offshore Plant (해양플랜트 프로세스 배관 내경 플러싱 오일속에서 수분제거를 위한 실험적 품질 특성)

  • Park, Chang-Soo;Sung, Ki-Young;Han, Seong Jong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.6
    • /
    • pp.797-805
    • /
    • 2019
  • An important problem of offshore plant process piping is equipment accidents due to the removal of fine metal debris and foreign substances in the pipes that deliver fluids such as hydraulic oil, lubricating oil and thermal oil. Temporary flushing equipment to remove debris uses fluid equipment of centrifugal pump and gear pump to prevent equipment accident of offshore platform. The equipment manufacturer requires the shipyard to have a cleanliness rating inside the pipe to meet the international standards ISO4406 and NAS1638 quality levels to prevent damage to the equipment sold. The quality of the internal flushing of pipes conforms to the regulations suggested by the equipment manufacturer. In this paper, three types of electric heater capacity, which is a method of evaporating and removing water inside a pipe during an oil flushing process, were compared. In addition, the study was conducted to remove the flushing oil in the pipe and to improve oil quality.

Energy Efficient Control of Onboard Hydraulic Power Unit for Hydraulic Bipedal Robots (유압 구동식 이족 로봇의 구동을 위한 탑재식 유압 파워 유닛의 에너지 효율적 제어)

  • Cho, Buyoun;Kim, Sung-Woo;Shin, Seunghoon;Kim, Min-Su;Oh, Jun-Ho;Park, Hae-Won
    • The Journal of Korea Robotics Society
    • /
    • v.16 no.2
    • /
    • pp.86-93
    • /
    • 2021
  • This paper proposes a controller to regulate the supply pressure of the hydraulic power unit (HPU) for driving a bipedal robot. We establish flow rate models for charging accumulator, actuating joints and leaking from actuators and spool valves. This determines the pump driving motor speed to satisfy the demanded flow rate for operating the bipedal robot without the energy loss caused by the bypass through a pressure regulating valve. We apply proposed controller to an onboard HPU mounted on top of bipedal robot platform with twelve degrees of freedom. We implement air-walking motion and squat motion which require variable flow rate to the bipedal robot. Through this experiment, the energy efficiency of proposed controller was verified by comparing the electric energy consumed when the controller was applied and when the pump operated at constant speed. We also shows the capability of the HPU's control performance to regulate supply pressure.

A study on economic evaluation when renewable energy system is introduced in public buildings inside of Daegu Sin-seo innovation city (대구신서혁신도시 내 공공건축물의 신재생에너지 시스템 도입시 경제성 평가에 관한 연구)

  • Kim, Bo-Ra;Kim, Ju-Young;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.175-180
    • /
    • 2009
  • According to an increasing demand of political support and development on renewable energy as a solution for the energy problem in Korea, the government has established a goal to raise renewable energy supply from 2.27% to 5% until 2011. Especially in the case of public building in which energy use is in great demand, it would bring a great advantage to develop and utilize the Photovoltaic System as an electric energy and Geothermal Heat Pump System as a thermal energy. On the occasion of Photovoltaic System, Photovoltaic module can be used as an architectural material so that it can reduce construction cost and when we use solar energy, it is possible to make building's own power supply. As for Geothermal Heat Pump System, It can be used infinitely as long as the solar energy exist and operation cost is cheap and yearly efficiency is stable. However, we need to make a plan to reduce early investment expanses for these two renewable energy systems and to expand a diffusion rate as we develop a competitive domestic technology level. So in this study, we are going to perform evaluation of economical efficiency according to the introduction of Photovoltaic System and Geothermal Heat Pump System in public buildings which will be built up inside of Daegu Sin-seo innovation city. As a first step, we will investigate present installation condition of these two renewable energy systems and based upon that, will seek efficient introduction program of renewal energy systems that can be applied in public buildings.

  • PDF