• Title/Summary/Keyword: Electric insulation material

Search Result 252, Processing Time 0.028 seconds

The Aging Characrteristic Analysis of Mica-Epoxy Insulation Materials (마이카-에폭시 절연재료의 열화특성분석)

  • Yoo, Yeong-Sik;Kim, Hee-Gon;Song, Woo-Chang;Lee, Jae-Hyung;Park, Yong-Kwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.2
    • /
    • pp.82-89
    • /
    • 1998
  • The experimental results using the X -ray technique, the position and structure of mica crystal are not observed the phase change of aging and sound specimen respectively. However, We could observe the intensity difference of crystal element in both atmospheres. The analysis of mica-epoxy materials by optical microscope are shown that the each surface of sound and aging specimens are different in both atmospheres Also, the experimental results have shown that the potassium ions of mica cristal are substituted by hydrogen ions at boundary area of mica-epoxy and/or mica-mica. On components made of mica, a potassium ion of big atomic radius, is replaced by hydrogen ion of small atomic radius. The voids are created by the difference of radius progressed by combined stresses. Through these phenomena, it has been proposed that the conductive layers made of potassium enable the voids to form and the cracks to create by high electric field.

  • PDF

The Aging Measurement of Water Tree Using AgNO$_3$Solution (AgNO$_3$을 이용한 수트리의 실시간 열화계측)

  • Kim, Duck-Keun;Ooh, Soo-Hong;Lee, Jin;Lee, Eun-Hak;Kim, Tae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.409-412
    • /
    • 1997
  • The phenomenon of water tree degradation of underground distribution power cables is taking place in polymeric insulation materials under the existence of water and application of electric stress, but water tree is not easy to observe, o water tree features in power cables are shown after cutting and dying with methyleneblue. In previous method, it is impossible to acquire continuous treeing data, and when the insulation material has been cut, the micro crack(water tree) has been damaged. In this paper, to overcome these deflects, the etching method is made use of making needle electrode about 170[${\mu}{\textrm}{m}$] diameter, and AgNO$_3$(silver nitrate) solution is used as liquid electrode to accelerate the growth of water trees. As a result of this study, water tree is observed in real-time with microscope. Electrical tree owing to water treeing is initiated at low electric field and grown with discontinuous. Namely, water tree is shown up a different characteristics of tree growth.

  • PDF

Electrical characteristics of PET film for wire insulation of transformer in fluorocarbon (Fluorocarbon에서의 변압기권선 절연용 PET필름의 전기적 특성연구)

  • 허창수;이재복
    • Electrical & Electronic Materials
    • /
    • v.9 no.5
    • /
    • pp.483-489
    • /
    • 1996
  • Power transformer have many unsymmetrical structure and electric field is enhanced in that area. Those unsymmetrical area are not covered oftenly by solid insulating material which is used as a framework specially in gas transformer. By that result there is a possibility to decrease the total insulation class of the transformer. So in this study the electrical characteristic of $FC+SF_6$ mixture gas which is used as coolants for large power gas insulated transformer and its effects on electrical characteristics of structural material are investigated. Also breakdown characteristic with the tension of taping and curvature of the coil are studied which could be used as a design factor of large power transformer.

  • PDF

The Crack Resistance and the Dielectric Breakdown properties of Epoxy Composities due to the Multi Stresses Variation (다중 응력 변화에 따른 에폭시 복합체의 내크랙성 및 절연 파괴 특성)

  • 송봉철;김상걸;안준호;김충혁;이준웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.136-139
    • /
    • 2000
  • Epoxy materials are used as insulation material for electric power cables. In the case of a flow of excess current due to the temperature difference which occurs between the heat of the conductor and the atmosphere, heat degrades connection point of the cables. Also, the mechanical stress, which occurs due to the thermal expansion coefficient of cable connection electrode system and epoxy insulation materials along with the gap between thermal conduction based on the extra high voltage of transmitted voltage, increases possibility of cracks to occur. The relationship between mechanical stress and electrical breakdown mechanism is verified for the epoxy materials such as high toughness epoxy materials, which comes to be used contemporarily, and for the breakdown mechanism of epoxy materials on the multi-stresses (mechanical and electrical) due to the variation of the temperature.

  • PDF

A study on the reduction of PD generated in the PT for 25.8 kV (25.8 kV용 PT에서 발생하는 부분방전 저감에 관한 연구)

  • 송재주;이중근;김성홍;서용균;나도간;한병성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.631-635
    • /
    • 2000
  • Recently, the epoxy molded type PT for indoor and applied 25.8kV was often distroyed by degradation of insulation that effected many electric stress and defect of manufactured goods. therefore In this work, We can present a method of solution in the process of produce the PT through analysis of experiments. In order to reduce the PD (Partial Discharge) which was occurred at the insulation material of epoxy resin, we has many tried to remove faults In the process of the products,

  • PDF

Cavity and Interface effect of PI-Film on Charge Accumulation and PD Activity under Bipolar Pulse Voltage

  • Akram, Shakeel;Wu, Guangning;Gao, GuoQiang;Liu, Yang
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2089-2098
    • /
    • 2015
  • With the continuous development in insulation of electrical equipment design, the reliability of the system has been enhanced. However, in the manufacturing process and during operation under continues stresses introduce local defects, such as voids between interfaces that can responsible to occurrence of partial discharge (PD), electric field distortion and accumulation of charges. These defects may lead to localize corrosion and material degradation of insulation system, and a serious threat to the equipment. A model of three layers of PI film with air gap is presented to understand the influence of interface and voids on exploitation conditions such as strong electrical field, PD activity and charge movement. The analytical analysis, and experimental results are good agreement and show that the lose contact between interfaces accumulate more residual charges and in consequences increase the electric field intensity and accelerates internal discharges. These residual charges are trapped charges, injected by the electrodes has often same polarity, so the electric field in cavities increases significantly and thus partial discharge inception voltage (PDIV) decreases. Contrary, number of PD discharge quantity increases due to interface. Interfacial polarization effect has opposite impact on electric field and PDIV as compare to void.

A Study on Performance Evaluation of On-board Electric Device of TTX(Tilting Train Express) (틸팅열차(TTX)의 정장품 성능평가 연구)

  • Han, Seong-Ho;Lee, Su-Gil;Seo, Sung-Il
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2005.11a
    • /
    • pp.239-242
    • /
    • 2005
  • This paper introduced an approach of improvement of performance of Electric device for EMU type Train like as TTX. The electric equipments are characterized by insulation, Noise, cooling system etc. and Their weight arc decided by these factors. There are two kinds of power source in EMU train. First, DC voltage source, 1500 volt, 750 volt is used for subway system. Second, AC power source 25000 volt is applied to high speed train and existing main lines. Composite material has the protection of inrush current and high frequency noise. We can use this material to minimize weight of train. Additionally we can get energy saving when operator service TTX.

  • PDF

Thermal, Mechanical, and Electrical Properties for EMNC_60 and EMNC_65 (EMNC_60과 EMNC_65에 대한 열적, 기계적, 전기적 특성 연구)

  • Park, Jae-Jun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.11
    • /
    • pp.895-901
    • /
    • 2012
  • In order to application for high voltage heavy electric equipments, epoxy/microsilica 60 wt%/nano layered silicate composites (EMNC_60) and epoxy/microsilica 65 wt%/nano layered silicate composites (EMNC_65) respectively was synthesized by our electric field dispersion method and the result was obtained completely dispersion state. Thermal properties such as glass transition temperature (Tg) and thermal expansion coefficient, and DMA characteristics were studied, and mechanical properties such as tensile and flexural tests were performed. AC electrical insulation strength was also tested. The study on thermal property, EMNC_65 was better than EMNC_60 and mechanical, electrical properties much improved EMNC_60 compared with EMNC_65.

A Study on Electric Field Dispersion Techniques of Epoxy-Nanocomposites for Application of High Voltage Power Apparatus (고전압 전력기기응용을 위한 에폭시-나노콤포지트의 전기장 분산기술연구)

  • Lee, Chang-Hoon;Kim, Hyo-Chul;Cho, Young-Haw;Kim, Hyun;Jo, Sung-Choe;Park, Jae-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.97-97
    • /
    • 2010
  • A new electric application method was developed to prepare epoxy/organoclay nanocomposite for the electrical insulation in the AC electric fields and it could be also used in the field of various viscous polymer/organoclay systems. The applied AC electric field condition was as follows; (1) inter-electrode distance: 40 mm, (2) application voltage: 3-11 kV, (3) frequency: 60~1,000 Hz, and (4) application time: 0~60 min. To characterize the epoxy/clay nanocomposite, WAXS and TEM analyses were confirmed. In order to explain how the organic modifier affects the exfoliation phenomena, a mechanism of the oscillating collision of the quaternary ammonium head was proposed and the effects of the AC voltage and frequency and the organoclay content were studied.

  • PDF

A study on Electrical Potential Characteristics of HDPE Mixed with EVA (HDPE/EVA혼합수지의 전기적 분포 특성에 관한 연구)

  • Jung, Eui-Hwan;Heo, Jun;Lee, Seung-Su;Lim, Kee-Joe;Lee, Hyung-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1447_1448
    • /
    • 2009
  • In this paper, each specimen blended at weight proportions of 80% HDPE to 20% EVA, 70% HDPE to 30% EVA, 60% HDPE to 40% EVA, and 50% HDPE to 50% EVA was manufactured respectively. The insulation performances of the proposed insulator were compared with conventional XLPE, main insulating material of CV cable on the basis of the investigation results of DC insulation performances. From the space charge density, electric field and potential profiles with raising DC voltage and time variation in HE82, distortion of electric field distribution was improved. As EVA mixed into the bulks acts as nucleation in crystallization process of HDPE, the size of spherulites became decreased and finally formed continuous network structure. Ultimately it resulted from extinction of space charge in the interfacial region of spherulites.

  • PDF