• Title/Summary/Keyword: Electric heating equipment

Search Result 46, Processing Time 0.035 seconds

Economic Analysis of Heat Pump System in Educational Building -Focused on the High School of Twenty Four Classes- (교육용 건축물의 히트펌프 냉난방시스템에 대한 경제성 분석 -24학급 규모의 고등학교를 중심으로-)

  • Park, Ryul;Park, Min-Yong;Kim, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.10
    • /
    • pp.879-887
    • /
    • 2003
  • Buildings with heating and cooling systems have been increased, since the requirement of thermal comfort for residents is grown. Heating and cooling systems, have been changed from two separate systems to one multi-function system which includes both heating and cooling. Especially, heat pump heating and cooling system has been adopted for general classrooms in schools since education environment improvement project has been launched. This research suggests the best option for the heat pump heating and cooling system in educational buildings through economic assessments for four alternative systems based on electric heat pump (EHP) and gas engine driven heat pump (GHP), which are most widely used for elementary, middle and high schools. The model buildings are in the Y high school which has 24 classes of new construction building, which will be built soon. Annual energy consumption for alternative systems uses BECS 3.10, which can be used for system simulation.

A study on present status and improvement of protection relay system in subway station for stable power supply (지하철 역사의 안정적 전원공급을 위한 보호시스템 검토)

  • Na, Jong-Woo;Jo, Won-Kang;Park, Dong-Seon;Yoo, Yeon-Seong;Moon, Hwa-Soo
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.433-444
    • /
    • 2008
  • Nowadays, subway station has provided not only transportation but living spaces for everyday activities. Therefore, a variety of facilities have been installed for a safety of citizens such as fire-fighting equipment, platform screen doors and giving high level of benefits such as air-conditioning and heating equipment, escalators, lighting apparatus. In order to operate these facilities appropriately, it is needless to say that electric power supply must be reliable. Many protection relays have been installed to protect electric apparatus and power system, nevertheless it..s study has been insufficient in the concrete. From this paper, through analyzing of protection relay system of electric room operated in line 2 of Seoul metro, we can help to improve stable power supply system of subway station.

  • PDF

The Thermal Characteristics of Partially Disconnected Wire Happened in Plug (플러그 내부에서 발생된 소선 단선에 의한 발열특성)

  • Jee, Seung-Wook;Kim, Shi-Kuk;Lee, Chun-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.104-110
    • /
    • 2011
  • There are over 30[%] of electric fires in Korea happened at wire or wiring devices. For its prevention many safety devices are set up electric equipments. These safety devices are not working in a rated current's condition of electric equipment. But when wire is partially disconnected, electric fire is able to be happened even though current is smaller than a rated current value. This paper studied thermal characteristics and fire ability when wire in plug is partially disconnected. The experiment is progressed a method that inner wire of plug is partially disconnected and after that current that is less than a rated current is flowed. As the result, heating occurred in near of partially disconnected wire makes that outer sheath is melted, plug cover is carbonized, and even sometimes wire is fused. And results of analysis of thermal image of partially disconnected wire happened in plug, it shows a difference to heating distribution and temperature appeared surface of plug depend on a progress of a partially disconnected wire.

A MATLAB-based Approach for Visualization of Human Thermal Psychology (MATLAB 기반 열심리 가시화 기법)

  • Gineesh Gopi;Mohammad F. B. Suhaimi;Seong Eun Yoon;Hyunjin Lee;Jung Kyung Kim
    • Journal of the Korean Society of Visualization
    • /
    • v.21 no.2
    • /
    • pp.72-82
    • /
    • 2023
  • Effective thermal management in a battery electric vehicle (BEV) is crucial for reducing energy consumption and maximizing driving range in cold climates. Consequently, original equipment manufacturers are actively investing in the development of local heating systems. Visualizing occupant thermal behaviors or comfort can readily provide valuable insights that would substantially impact the design and control strategies of such microclimate systems. This study uses MATLAB for three-dimensional visualization of human thermal psychology. The developed program enables qualitative assessment of occupant comfort in BEVs.

A Study on Developmemt of Heat-Emission Prevention Device for SSR (무접점스위치(SSR) 발열 방지 장치 개발에 대한 연구)

  • Lee, Man-Soo;Kim, Jun-Yong;Kim, Jin-Bae
    • Journal of the Korea Safety Management & Science
    • /
    • v.21 no.4
    • /
    • pp.25-30
    • /
    • 2019
  • Electric of using in daily life is always exposed to risk of electrical fire and electric shock. Only degree of risk is different, there is no risk free electrical product. Generally, the higher voltage, the risk of electric shock is high. The much electric current, the risk of electrical fire is high. But, we can't help using electric because of risk and we effort to reduce the risk of electrical fire and electric shock. This study deal with the fire prevention generated on heating equipment using SSR for current.

A Development of Simulator to Assessment for Loss Saving of Harmonic Electric Power Energy (고조파 전력에너지의 손실절감량 산정 시뮬레이터 개발)

  • Kim, Yong-Ha;Jo, Hyun-Mi;Heo, Dong-Ryeol;Park, Jong-Min;Park, Hwa-Yong;Yoo, Jeong-Hui
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1272-1273
    • /
    • 2011
  • A study on demonstration to development of simulator to assessment for loss saving of harmonic electric power energy. harmonic occurs to electric equipment like increase of terminal voltage, resonance phenomena occurrence and noise. To circulate of loss saving of harmonic electric power energy, we assessment electric power loss saving by harmonic and estimate loss saving of far-infrared radiation panel heating system.

  • PDF

A Study on the Energy Saving of Electric Railway System (전기철도에서의 에너지 절감 방안에 관한 연구 (조명등 및 전동차 운용 실측 분석))

  • Lee Gi-Seung;Min Byung-Hoon;Kim Hak-Lyun;Chang Sang-Hoon
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1316-1321
    • /
    • 2004
  • Recently, since demands of energy saving and efficiency for electric railway system have been increased, the study for electrical operation system is needed. Therefore, case study according to increase of energy consumption, investigate the actual conditions of the operation of electric cars and lightings were analyzed. From the results therefore, it is found that the energy consumption of electric car is much more winter than summer, because heating for protect of the air pipe frozen. But the energy consumption of electric equipment of station office is much more summer than winer, the reason for air-conditioner. In future, according to outdoor air temperature and ridership, ,wish to study about system that can operate cold, block heater automatically.

  • PDF

A study on performance test of water heat storage type heat-pump system using cooling tower heat source (냉각탑을 이용한 축열식 히트펌프시스템의 성능측정에 관한 연구)

  • Lee, Sang-Hoon;Park, Hyo-Sik;Han, Woo-Yong;Kim, Uk-Jung
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1099-1104
    • /
    • 2008
  • Recent year, mean energy consumptions of a people are higher than other country. And international oil price became over 120 dollar. This energy environment as well as energy war. Maybe, the Meteorological Administration is going to enforce scorching heatwave special report system from that come summer. Besides, 2008 summer, maximum demand power is expected by 64,240,000kW. The electric power equipment reserve rate appeared in to keep 12.5% level. Chilled water storage system witch is one of electric load administration system. Heat pump system used cooling tower heat recovery is advantage that use is possible to summer in small a public bath building. In this paper, we suggest that heat pump system by heat recovery using cooling tower when it is heating operation of ambient air temperature. To apply cooling tower heat recovery heat pump to chilled water heat storage type and achieved performance evaluation about operation. As a result, performance of heat pump system that about 121% in cooling mode, 138% in heating mode higher than KEPCO standard. And heating operation possible to ambient air temperature about $23^{\circ}C$, which of appear cooling tower outlet temperature about $13^{\circ}C$.

  • PDF

Development of Auxiliary Heater to Improve Korean Medical Evacuation Helicopter Winter Operational Capability

  • Kim, Se Un;Koo, Jeong Mo;Seo, Jeong Mi;Jeong, Won Chae
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.6
    • /
    • pp.10-17
    • /
    • 2020
  • The Korean medical evacuation helicopter was developed based on the Korean Utility Helicopter (hereafter referred to as 'Surion'). It uses an auxiliary power unit and engine for heating during winter operation. The helicopter maintains the internal temperature of the aircraft using its bleed air to satisfy its operational capability. However, due to the air inflow through the gap between the aircraft skin and door, additional heating for operating the portable medical equipment and preventing hypothermia in evacuated patients is required. Accordingly, an electric auxiliary heater was developed for additional heating during winter operation, and environmental, durability, and performance tests were conducted per MIL-STD-810G and MIL-STD-461F. The auxiliary heater was verified per the tailored airworthiness certification criteria.

An Applicability Estimation of Plastic Vertical Pipes using Electric Fusion Fittings through Measurement (실측을 통한 융착식 플라스틱 입상배관 성능 평가)

  • Park, Yool;Ahn, Young-Chull;Kim, Hyun-Dae;Kim, Jeong-Su;Goark, You-Shik;Kim, Young-Kyoung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.11
    • /
    • pp.595-599
    • /
    • 2013
  • The pipes used in buildings are generally categorized into metallic or plastic materials. Metal pipes, such as copper and stainless steel pipes, are mainly used for water and hot water supply, and for the heating system. However, plastic pipes made of polyethylene and cross-linked polyethylene are used for floor heating, water drainage, and air vent systems. Usually, plastic pipes have thermal demerits, such as high linear expansion coefficients and bending phenomenon by hot water, although the pipes have several merits of light weight, low price, low thermal conductivity, and the comparatively high workability of metal pipes. Therefore, if those kind of demerits are overcome, plastic pipes can be easily accepted for hot water systems. This research is aimed to evaluate the applicability for vertical heating pipes of a plastic pipe system consisting of electric fusion fitting of a conductive carbon compound and propylene random glass fiber pipe, through measurement of the expansion rate and leakage in summer and winter seasons, in the apartment construction field.