• Title/Summary/Keyword: Electric breakdown

Search Result 688, Processing Time 0.026 seconds

Degradation Measurement from Electrical Tree Image Using Foreground Object Extracting Skill (전경 물체 추출 기법을 이용한 전기트리 영상에서 열화 측정)

  • Kim, Hyeng-Gyun;Joung, Ki-Bong;Go, Seok-Man;Oh, Moo-Song;Kim, Teh-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.270-273
    • /
    • 2001
  • Electrical tree is studied widely by manufacture state of insulating material fare and blazing fire diagnosis system of use in phenomenon of part discharge that happen for main cause of dielectric breakdown of equipment for electric power. Use process that draw tree pattern here measuring above zero to study special quality of this electricity tree, real-time processing by image processing is proposed because reproduction of tree blazing fire process drops and pattern of tree is difficult correct quantification of tree growth by existent visual observation by involution. This research presents general process that need in image processing of tree blazing fire, and that remove various noises that happen in above zero by measuring electrical tree dividing background and complete view in measured above zero taking advantage of specially proposed complete view object abstraction techniques effectively and quantification of tree becomes easy naturally, can apply to dielectric breakdown estimate because can chase growth process of tree.

  • PDF

A study on the growth of $Al_2{O_3}$ insulation films and its application ($Al_2{O_3}$절연박막의 형성과 그 활용방안에 관한 연구)

  • 김종열;정종척;박용희;성만영
    • Electrical & Electronic Materials
    • /
    • v.7 no.1
    • /
    • pp.57-63
    • /
    • 1994
  • Aluminum oxide($Al_2{O_3}$) offers some unique advantages over the conventional silicon dioxide( $SiO_{2}$) gate insulator: greater resistance to ionic motion, better radiation hardness, possibility of obtaining low threshold voltage MOS FETs, and possibility of use as the gate insulator in nonvolatile memory devices. We have undertaken a study of the dielectric breakdown of $Al_2{O_3}$ on Si deposited by GAIVBE technique. In our experiments, we have varied the $Al_2{O_3}$ thickness from 300.angs. to 1400.angs. The resistivity of $Al_2{O_3}$ films varies from 108 ohm-cm for films less than 100.angs. to 10$_{13}$ ohm-cm for flims on the order of 1000.angs. The flat band shift is positive, indicating negative charging of oxide. The magnitude of the flat band shift is less for negative bias than for positive bias. The relative dielectric constant was 8.5-10.5 and the electric breakdown fields were 6-7 MV/cm(+bias) and 11-12 MV/cm (-bias).

  • PDF

A Novel Classification of Polymorphs Using Combined LIBS and Raman Spectroscopy

  • Han, Dongwoo;Kim, Daehyoung;Choi, Soojin;Yoh, Jack J.
    • Current Optics and Photonics
    • /
    • v.1 no.4
    • /
    • pp.402-411
    • /
    • 2017
  • Combined LIBS-Raman spectroscopy has been widely studied, due to its complementary capabilities as an elemental analyzer that can acquire signals of atoms, ions, and molecules. In this study, the classification of polymorphs was performed by laser-induced breakdown spectroscopy (LIBS) to overcome the limitation in molecular analysis; the results were verified by Raman spectroscopy. LIBS signals of the $CaCO_3$ polymorphs calcite and aragonite, and $CaSO_4{\cdot}2H_2O$ (gypsum) and $CaSO_4$ (anhydrite), were acquired using a Nd:YAG laser (532 nm, 6 ns). While the molecular study was performed using Raman spectroscopy, LIBS could also provide sufficient key data for classifying samples containing different molecular densities and structures, using the peculiar signal ratio of $5s{\rightarrow}4p$ for the orbital transition of two polymorphs that contain Ca. The basic principle was analyzed by electronic motion in plasma and electronic transition in atoms or ions. The key factors for the classification of polymorphs were the different electron quantities in the unit-cell volume of each sample, and the selection rule in electric-dipole transitions. The present work has extended the capabilities of LIBS in molecular analysis, as well as in atomic and ionic analysis.

LIBS Analysis on Magnetic Force of Dissimilar Material Using SMAW (이종재료의 피복아크 용접에서 자기력에 따른 LIBS 해석)

  • Lee, Chul Ku;Lee, Wooram
    • Journal of Welding and Joining
    • /
    • v.31 no.4
    • /
    • pp.54-61
    • /
    • 2013
  • This paper reports mild steel(SPHC) and stainless steel(STS304) sheets commonly used for railroad cars or commercial vehicles such as in the automobile and shipbuilding industries. The sheets are used in these applications, which are mainly fabricated using the shielded metal arc welding(SMAW) of dissimilar materials. It also reports an interesting application of Laser Induced Breakdown Spectroscopy(LIBS) in order to determine the elemental composition diffusion of SPHC and STS304. Arc blow produced by magnetic force during the electric arc welding prevents the formation from a sound weldment. In particular, the mechanical properties of the joint are influenced by not only by geometrical and mechanical factors but also the welding conditions for the arc welded joint. Therefore, the mechanical properties and performance are evaluated by performing a physicochemical component analysis. And they increase in accordance with content of elements and microstructure in mild steel. As results, appropriate range for magnetic fields could be achieved. Therefore, the effect of magnetic force in a butt weld of mild steel plates was investigated by comparing to the measured data.

Dielectric and Electrical Properties of $Sr_{0.9}Bi_{2+x}Ta_2O_9$ Thin Films on $IrO_2$ Electrode ($IrO_2$를 하부전극으로 사용한 $Sr_{0.9}Bi_{2+x}Ta_2O_9$ 박막의 유전 및 전기적 특성)

  • 박보민;송석표;정병직;김병호
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.3
    • /
    • pp.233-239
    • /
    • 2000
  • Sr0.9Bi2+xTa2O9(x=0, 0.1, 0.2, 0.3) thin films on IrO2/SiO2/Si or Pt/Ti/SiO2/Si substrate were prepared by spin coating method using SBT stock solutions synthesized by MOD process. SBT thin films on IrO2 transformed to layered perovskite phase at $700^{\circ}C$, but showed low breakdown voltage due to their porous microstructure. The smaple of Sr0.9Bi2+xTa2O9 composition showed the best dielectric and electrical properties. When the sample of the same composition was annealed at 80$0^{\circ}C$, the dielectric and electric properties were improved due to the grian growth and dense surface. the remanent polarization values(2Pr) at $\pm$3 V for IrO2 and Pt electrodes were 10.5, 7.15$\mu$C/$\textrm{cm}^2$, respectively. The SBT thin film with IrO2 electrode showed the lower coercive field. The leakage current density and breakdown voltage of SBT thin films on IrO2 were higher than those on Pt.

  • PDF

A Characteristic of Tracking Progress Happened at the End of the VCTFK (VCTFK 끝단에서 발생되는 트래킹의 진전특성)

  • Jee, Seung-Wook;Kim, Shi-Kuk;Ok, Kyung-Gea;Lee, Chun-Ha;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.8
    • /
    • pp.78-83
    • /
    • 2010
  • This paper describes the characteristic of tracking progress happened at the end of the polyvinyl chloride insulated cabtyre oval cord(VCTFK) that is widely used for distribution cord. Tracking is occurred owing to the drop of electrolyte at the end of the VCTFK. The tracking progress and its characteristic happened at the end of the VCTFK are as follow; Carbonization and electrical erosion are happened at the end of the VCTFK. Electrical erosion is begun at the insulation layer near conductors. After that, it is also happened at the sheath layer. Accumulation of carbonized insulation and sheath materials at the end of the VCTFK is begun after progress of electrical erosion. When the accumulation is progressed arc discharge is appeared and finally it goes to tracking breakdown.

Effect of ceramic powder addition on the insulating properties of polymer layer prepared by dip coating method

  • Kim, S.Y.;Lee, J.B.;Kwon, B.G.;Hong, G.W.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.1
    • /
    • pp.14-18
    • /
    • 2014
  • The mechanical, electrical and thermal characteristics of insulating materials may significantly affect the performance and reliability of electrical devices using superconductors. General method to provide insulating layer between coated conductors is wrapping coated conductor with Kapton tape. But uniform and compact wrapping without failure or delamination in whole coverage for long length conductor is not a simple task and need careful control. Coating of insulating layer directly on coated conductor is desirable for providing compact insulating layer rather than wrapping insulating layers around conductor. Ceramic added polymer has been widely used as an insulating material for electric machine because of its good electrical insulating properties as well as excellent heat resistance and fairy good mechanical properties. The insulating layer of coated conductor should have high breakdown voltage and possesses suitable mechanical strength and maintain adhesiveness at the cryogenic temperature where it is used and withstand stress from thermal cycling. The insulating and mechanical properties of polymer can be improved by adding functional filler. In this study, insulating layer has been made by adding ceramic particles such as $SiO_2$ to a polymer resin. The size, amount and morphology of added ceramic powder was controlled and their effect on dielectric property of the final composite was measured and discussed for optimum composite fabrication.

Efficient Re-degaussing Technique for a Naval Ship Undergoing a Breakdown in Degaussing Coils

  • Kim, Dong-Wook;Lee, Sang-Kyun;Kang, Byungsu;Cho, Jeonghun;Lee, WooSeok;Yang, Chang-Seob;Chung, Hyun-Ju;Kim, Dong-Hun
    • Journal of Magnetics
    • /
    • v.21 no.2
    • /
    • pp.197-203
    • /
    • 2016
  • A naval ship equipped with a degaussing system may undergo a breakdown in degaussing coils at sea. In the case, underwater magnetic field around the ship abruptly grows up and it can make the ship be easily exposed to fatal hazards such as magnetic mines or torpedoes. This paper proposes an efficient and practical re-degaussing technique for a ship where a part of degaussing coils is out of order. To achieve this, an analytical design sensitivity formula and approximated degaussing coil field are exploited, and then new optimum currents of available coils are reassessed. To validate the proposed method, a muck-up ship equipped with 14 degaussing coils is tested in scale-down magnetic treatment facilities under three faulty coil conditions.

Electrical Properties of Low Density Polyethylene Film by Superstructure Change (고차구조 변화에 따른 저밀도폴리에틸렌 박막의 전기적 특성)

  • Shin, Jong-Yeol;Shin, Hyun-Taek;Lee, Soo-Won;Hong, Jin-Woong
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.4
    • /
    • pp.101-109
    • /
    • 2002
  • The electrical properties of polyethylene are changed by the superstructure. Such crystalline polymer as polyethylene or polypropylene changes crystallinity and products spherulite or trans-crystal when it is cooled slowly. In this study, after thermal treatment of LDPE at 100[${circ}C$], in silicone oil for an hour, we made specimens in order of slow cooling, water cooling, quenching according to cooling speed. Also, to study the influence of electrical properties due to the superstructure change, we analyzed physical properties and performed dielectric breakdown experiments using DC and impulse voltage Moreover we measured space charges in bulk using Laser Induced Pressure Pulse(LIPP) method. Trap level of specimen is 0.064[eV] at the low temperature region 0.31[eV] at the high temperature region in DC dielectric strength, 0.03[eV] at the low temperature region 0.0925[eV] at the high temperature region in impulse dielectric strength. As its result shows that the quantity of charges induced from the electrode surface increases with applied voltage time, and the distribution of space charges in samples increases the quantity of charges in proportion to applied voltage.

The effect of magnet fields on the corona discharge (코로나 방전에 대한 자계의 영향)

  • 박재윤;정장근;김익균
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.3
    • /
    • pp.51-56
    • /
    • 2001
  • In this paper, the effect of magnetic field on corona discharge phenomena was experimentally investigated in the needle-plate electrode geometry. Needle-plate geometry discharge system with magnetic field at a right angle to the electric field was made. The corona discharge characteristics with magnetic field were investigated and compared with the corona characteristics without magnetic field in atmospheric pressure. As a result, in case of positive DC corona discharge with magnetic field, corona discharge zone was significantly wider, corona current was lower, and breakdown voltage was higher than those without magnetic field. However, in case of negative DC corona discharge with magnetic field, corona current was slightly higher and breakdown voltage was lower than those without magnetic field. It is thought that this result is due to cyclotron motion of charged particles such as electron and ion by magnetic field.

  • PDF