• 제목/요약/키워드: Electric Potential Output

검색결과 51건 처리시간 0.027초

우리나라 전력시장에서의 시장지배력 행사 (Market Power in the Korea Wholesale Electricity Market)

  • 김현실;안남성
    • 한국시스템다이내믹스연구
    • /
    • 제6권1호
    • /
    • pp.99-123
    • /
    • 2005
  • Although the generation market is competitive, the power market is easily exercised the market power by one generator due to its special futures such as a limited supplier, large investment cost, transmission constraints and loss. Specially, as Korea Electric industry restructuring is similar US competitive wholesale electricity market structure which discovered the several evidences of market power abuse, when restructuring is completed the possibility that market power will be exercised is big. Market power interferes with market competitions and efficiency of system. The goal of this study is to investigate the market price effects of the potential market power and the proposed market power mitigation strategy in Korean market using the forecasting wholesale electricity market model. This modeling is developed based on the system dynamics approach. it can analyze the dynamic behaviors of wholesale prices in Korean market. And then it is expanded to include the effect of market condition changed by 'strategic behavior' and 'real time pricing.' This model can generate the overall insights regarding the dynamic impact of output withholding by old gas fire power plant bon as a marginal plant in Korean market at the macro level. Also it will give the energy planner the opportunity to create different scenarios for the future for deregulated wholesales market in Korea.

  • PDF

몽골의 심부 지열에너지 자원과 지열발전에 관한 연구 (A Study on Deep Geothermal Energy and Potential of Geothermal Power Generation in Mongolia)

  • 한정상;윤운상;김영식;한찬;박유철;목종구
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권3호
    • /
    • pp.1-11
    • /
    • 2012
  • Mongolia has three(3) geothermal zones and eight(8) hydrogeothermal systems/regions that are, fold-fault platform/uplift zone, concave-largest subsidence zone, and mixed intermediate-transitional zone. Average temperature, heat flow, and geothermal gradient of hot springs in Arhangai located to fold-fault platform/uplift zone are $55.8^{\circ}C$, 60~110 mW/m2 and $35{\sim}50^{\circ}C/km$ respectively and those of Khentii situated in same zone are $80.5^{\circ}C$, 40~50 mW/m2, and $35{\sim}50^{\circ}C/km$ separately. Temperature of hydrothermal water at depth of 3,000 m is expected to be about $173{\sim}213^{\circ}C$ based on average geothermal gradient of $35{\sim}50^{\circ}C/km$. Among eight systems, Arhangai and Khentii located in A type hydrothermal system, Khovsgol in B type, Mongol Altai plateau in C type, and Over Arhangai in D type are the most feasible areas to develop geothermal power generation by Enhanced Geothermal System (EGS). Potential electric power generation by EGS is estimated about 2,760 kW at Tsenher, 1,752 kW at Tsagaan Sum, 2,928 kW at Khujir, 2,190 kW at Baga Shargaljuut, and 7,125 kW at Shargaljuut.

알칼리금속 열전기변환장치의 접합과 출력성능 (Joining and Performance of Alkali Metal Thermal-to-electric Converter (AMTEC))

  • 서민수;이욱현;우상국
    • 대한기계학회논문집A
    • /
    • 제41권7호
    • /
    • pp.665-671
    • /
    • 2017
  • 알칼리금속을 이용한 열전기변환장치(Alkali-Metal Thermal-to-electric Converter)는 열을 전기로 직접 변환하는 기술이다. AMTEC 기술은 기존 에너지기술 대비 고효율성과 고밀도성을 지니는 정적 에너지 변환 장치로서 이론 발전효율이 40%로 높고 단위발전량이 500 W/kg, $2.01W/cm^2$로 우수하다. AMTEC의 작동원리는 작동유체인 소듐이 분압차이에 의해서 고체전해질인 베타알루미나(BASE)의 내부에서 외부로 이온화를 거쳐며 통과하는데, 이때 전자를 주고 받으며 전기를 생성한다. BASE내외부의 분압차 형성을 위해서는 고온내구성과 기밀성이 높은 접합기술이 요구된다. 개발된 접합기술을 이용하여BASE/절연부/금속부 시스템의 안정적인 전기적/구조적 시스템을 구성하고 멀티-셀 모듈들을 제작하여 개방회로 전압과 전류-전압특성을 측정하는 방법으로 AMTEC 모듈전지들의 출력성능과 수명을 평가하였다.

경량전철 개발에 따른 경제적 파급효과 분석 연구 (The Feasibility Study of a Light Rail Transit Development)

  • 남두희;임관수;이진선
    • 한국철도학회논문집
    • /
    • 제13권1호
    • /
    • pp.119-124
    • /
    • 2010
  • 경량전철시스템은 대도시내 주요 거점을 연결하는 간선교통, 지하철 노선이 닿지 못하는 지역의 교통수요를 기존 지하철에 연결시키는 개념의 지선 및 순환교통, 그리고 공항, 위락지역 등 대단위 교통 밀집지역의 접근교통 등의 역할을 한다. LIM, 노면전차, 모노레일 도입시 시장성과 경제성분석을 통해 각 시스템의 도입 타당성을 제시하고 국내 환경에 적합한 시스템 개발 및 향후 국외 시장의 선점효과를 정량적으로 제시하고자 하였다. 이에 경량전철의 특징 및 국내외 도입현황을 분석하였으며, 경제적 타당성 분석을 위해 산업연관분석을 하여 매출 및 부가가치를 전망하고 최종적으로 비용-편익 분석을 수행한 결과 대상 시스템 모두 경제성이 있는 것으로 분석되었다. 이러한 비용편익비율은 향후 경량전출 도입은 효율성으로 의미하기 보다는 사업성의 유무 판단으로 사용하는 것이며, 모든 시스템에 있어 경제성이 있는 것으로 판단된 만큼, 노선별 특성에 맞는 시스템 도입을 위한 다양한 방식의 경량전철 개발이 필요함을 알 수 있다.

Wave energy conversion utilizing vertical motion of water in the array of water chambers aligned in the direction of wave propagation

  • Hadano, Kesayoshi;Lee, Ki Yeol;Moon, Byung Young
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제9권3호
    • /
    • pp.239-245
    • /
    • 2017
  • As a new technical approach, wave energy converter by using vertical motion of water in the multiple water chambers were developed to realize actual wave power generation as eco-environmental renewable energy. And practical use of wave energy converter was actually to require the following conditions: (1) setting up of the relevant device and its application to wave power generation in case that severe wave loading is avoided; (2) workability in installation and maintenance operations; (3) high energy conversion potential; and (4) low cost. In this system, neither the wall(s) of the chambers nor the energy conversion device(s) are exposed to the impulsive load due to water wave. Also since this system is profitable when set along the jetty or along a long floating body, installation and maintenance are done without difficulty and the cost is reduced. In this paper, we describe the system which consists of a float, a shaft connected with another shaft, a rack and pinion arrangement, a ratchet mechanism, and rotary type generator(s). Then, we present the dynamics model for evaluating the output electric power, and the results of numerical calculation including the effect of the phase shift of up/down motion of the water in the array of water chambers aligned along the direction of wave propagation.

3상 계통연계형 태양광 PCS의 단독운전검출을 위한 개선된 무효전력변동기법 (Improved RPV(reactive-power-variation) anti-islanding method for grid-connected three-phase PVPCS)

  • 이기옥;정영석;소정훈;유병규;유권종;최주엽;최익
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1159-1160
    • /
    • 2006
  • As the grid-connected photovoltaic power conditioning systems (PVPCS) are installed in many residential areas, this has raised potential problems of network protection on electrical power system. One of the numerous problems is an Island phenomenon. There has been an argument that because the probability of islanding is extremely low it may be a non-issue in practice. However, there are three counter-arguments: First, the low probability of islanding is based on the assumption of 100% power matching between the PVPCS and the islanded local loads. In fact, an island can be easily formed even without 100% power matching (the power mismatch could be up to 30% if only traditional protections are used, e.g. under/over voltage/frequency). The 30% power-mismatch condition will drastically increase the islanding probability. Second, even with a larger power mismatch, the time for voltage or frequency to deviate sufficient to cause a trip, plus the time required to execute the trip (particularly if conventional switchgear is required to operate), can easily be greater than the typical re-close time on the distribution circuit. And, third, the low-probability argument is based on the study of PVPCS. Especially, if the output power of PVPCS equals to power consumption of local loads, it is very difficult for the PVPCS to sustain the voltage and frequency in an island. Unintentional islanding of PVPCS may result in power-quality issues, interference to grid-protection devices, equipment damage, and even personnel safety hazards. So the verification of anti-islanding performance is strongly needed. In this paper, the authors propose the improved RPV method through considering power quality and anti-islanding capacity of grid-connected three-phase PVPCS in IEEE Std 1547 ("Standard for Interconnecting Distributed Resources to Electric Power Systems"). And the simulation and experimental results are verified.

  • PDF

2차원 N-P-N 바이폴라 트랜지스터의 수치해석-BIPOLE (Numerical Analysis of a Two-Dimensional N-P-N Bipolar Transistor-BIPOLE)

  • 이종화
    • 대한전자공학회논문지
    • /
    • 제21권2호
    • /
    • pp.71-82
    • /
    • 1984
  • 2차원 n-p-n 바이폴라 트랜지스터의 수치해석을 위한 프로그램(BIPOLE)을 개발하였다. 이 프로그램은 SRH와 Auger 재결합 기구들과 불순물 농도와 전계강도에 대한 운송자 이동도의 의존성과 밴드 갭 축소 효과들을 포함하고 있다. Poisson 방정식에는 Newton법을 또 정공과 전자의 연속 방정식에는 발산이론을 이용하여 여러가지 물리적인 제한없이 기본 반도체 방정식들에 대한 유한차분 공식들을 만들었다. 선형화된 방정식들의 계수 행렬은 희소 대칭 M 행렬이었는데 그 해를 구하기 위해 ICCG법과 Gummel의 알고리즘을 적용하였다. 이 프로그램 BIPOLE를 n-p-n 트랜지스터의 여러가지 정상 상태 문제에 적용시켰다. 그 응용의 보기로서 공통 에미터 전류이득의 변화, 에미터 용량에 대한 확산용량이 미치는 영향과 입출력 특성곡선들을 계산해 보았다. 전위 분포와 전자와 정공 농도분포와 같은 계산 결과를 3차원 컴퓨터 그래픽으로 도시하였다. 이 프로그램은 장차 2차원 트랜지스터의 교류 및 왜곡 현상의 수치해석의 기초로 이용될 것이며, 이 프로그램에 관심있는 모든 분들께 공급될 것이다.

  • PDF

터빈설치를 위한 한국 연안 해상풍력발전 부존량 평가 (Assessment of Offshore Wind Power Potential for Turbine Installation in Coastal Areas of Korea)

  • 강금석;오남선;고동휘;정신택;황재동
    • 한국해안·해양공학회논문집
    • /
    • 제30권4호
    • /
    • pp.191-199
    • /
    • 2018
  • 본 연구에서는 한국 연안의 해상풍력 발전을 위한 적지를 검토하기 위해 기상청에서 제공하는 20개 지점의 풍속 자료를 수집하고 이를 분석하였다. 관측된 풍속 자료의 분석을 위하여 Rayleigh 모델과 Weibull 모델을 이용하였으며, 풍속 출현빈도에 따라 연간 부존량을 추정하였다. 풍력발전기 모델로는 출력 1.5~5 MW의 7종류를 선정하여 각각의 성능곡선을 이용하였다. 그 결과, 풍속이 7.15 m/s 이상인 지점에서는 Repower-5 MW의 터빈이 높은 에너지 생산이 가능한 것으로 나타났으나 그 이하의 풍속에서는 G128-4.5 MW의 터빈이 유리한 것으로 나타났다. 10 m/s 이상의 풍속 출현율이 높은 마라도, 거제도 및 포항의 경우 REpower사의 5 MW급 해상풍력발전기 설치 시 설비이용률이 56.49%, 50.92%, 50.08%로 높게 나타났다.

EIS(Electro Interstitial Scan) 방법의 임상적 유효성 연구 (Evaluation of Clinical Usefulness of EIS(Electro Interstitial Scan))

  • 김수찬;배장한;전민호;김재욱
    • 전자공학회논문지
    • /
    • 제52권12호
    • /
    • pp.124-133
    • /
    • 2015
  • 전기체간스캔법(EIS, electro interstitial scan)은 미세 직류전류를 인체의 사지말단 또는 국소적 인가를 통해 인체의 전류 반응을 기준으로 인체의 질병 유무를 판별할 수 있는 비침습적인 질병 스크리닝 방법으로 가능성을 보이고 있다. 프랑스에서 개발된 DDFAO는 다채널 EIS로 다양한 질병, 특히 당뇨와 같은 내분비 기관의 진단에 효과적이라고 주장한다. 본 연구에서는 RC 팬텀 모델을 이용하여 DDFAO의 측정의 반복성과 민감도를 확인하고, 정상군과 당뇨 질환군을 대상으로 임상적 유용성을 검정하였다. 그 결과, 팬텀을 이용할 경우, 반복 측정시 값의 변화가 없고 팬텀 특성이 변화될 때 DDFAO의 측정 결과도 변화되었다. 그러나 임상 측정에 있어서 6개의 표면 전극을 이용하여 비침습적 방법으로 정상인과 당뇨병 환자의 구별은 어려울 뿐만 아니라 반복성과 정확성도 우수하지 않았다. 그러나, 이러한 문제점에도 불구하고 측정 방법의 편리성과 간편성으로 인해 국소적인 영역보다 인체 전반적인 특성을 파악하는 스크린 장비로써의 개발 가능성은 여전히 보이고 있기에 EIS에 대한 다양한 기반 연구가 필요하다.

DPLL을 이용한 능동적 단독운전방지를 위한 무효전력변동법 (Reactive Power Variation Method for Anti-islanding Using Digital Phase-Locked-Loop)

  • 이기옥;유병규;유권종;최주엽;최익
    • 한국태양에너지학회 논문집
    • /
    • 제28권2호
    • /
    • pp.64-69
    • /
    • 2008
  • As the grid-connected photovoltaic power conditioning systems (PVPCS) are installed in many residential areas, these have raised potential problems of network protection on electrical power system. One of the numerous problems is an Islanding phenomenon. There has been an argument that it may be a non-issue in practice because the probability of islanding is extremely low. However, there are three counter-arguments: First, the low probability of islanding is based on the assumption of 100% power matching between the PVPCS and the islanded local loads. In fact, an islanding can be easily formed even without 100% power matching (the power mismatch could be up to 30% if only traditional protections are used, e.g. under/over voltage/frequency). The 30% power-mismatch condition will drastically increase the islanding probability. Second, even with a larger power mismatch, the time for voltage or frequency to deviate sufficiently to cause a trip, plus the time required to execute a trip (particularly if conventional switchgear is required to operate), can easily be greater than the typical re-close time on the distribution circuit. Third, the low-probability argument is based on the study of PVPCS. Especially, if the output power of PVPCS equals to power consumption of local loads, it is very difficult for the PVPCS to sustain the voltage and frequency in an islanding. Unintentional islanding of PVPCS may result in power-quality issues, interference to grid-protection devices, equipment damage, and even personnel safety hazards. Therefore the verification of anti-islanding performance is strongly needed. In this paper, improved RPV method is proposed through considering power quality and anti-islanding capacity of grid-connected single-phase PVPCS in IEEE Std 1547 ("Standard for Interconnecting Distributed Resources to Electric Power Systems"). And the simulation results are verified.