• Title/Summary/Keyword: Electric Load Factor

Search Result 178, Processing Time 0.032 seconds

FUNDAMENTAL RESEARCH OF A NOVEL 3/1 PHASE CONVERTER FOR ELECTRIFIED RAILROAD

  • Farshad, Siamak;Rongtai, Hao
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.955-960
    • /
    • 1998
  • Electrified railroads inject large amount of harmonics, negative sequence and reactive currents to electric supply systems. This paper introduces application of active filter as a 3/1 phase converter for electrified railroad. In this system active filter compensate harmonics, negative sequence and reactive currents and electric railroad and active filter together act as a balance three-phase load with power factor 1

  • PDF

Impact Factor Analysis of Response Adjustment Factor of PSC Composite Bridge Using Optical Fiber Sensor (광섬유 센서를 이용한 PSC 합성형교의 응답보정계수 영향인자 분석)

  • Kim, Ho Sun;Jang, Hwa Sup;Yang, Dong Woon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.1
    • /
    • pp.35-43
    • /
    • 2012
  • In general, load carrying capacity, one of the load & resistance capacities in bridges, has more margins than the load carrying capacity evaluated with theoretical methods, unless there are severe damages, defects or material deterioration phenomena that can have a great impact on the behavior of bridges. However, errors have been already included in the current processes of loading tests and structural analysis for measuring load carrying capacity, thus devaluing the reliability of response adjustment factor. Therefore, this study found out the problems of existing electric resistance strain and displacement sensors in sensor suite to solve the problems with sensors and the errors in the appropriateness of structural analysis model, thereby leading to the changes into an optical fiber smart sensor with excellent performance. Besides, the study attempted to ensure the accuracy of response adjustment factor by selecting the optimal models through the interpretation of various structural analysis models.

A Constant Current Regulated Inverter System for Lighting and Beaconing of Aerodromes (항공관제용 정전류조정(CCR) 인버터 시스템의 개발)

  • Shon, Jin-Geun;Park, Jong-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2006.10b
    • /
    • pp.141-146
    • /
    • 2006
  • According as level of industry develops day after day, electricity load system of industry requires high level control, effectiveness and high efficiency. Among supply and control unit of suitable power supply in these load characteristic, inverter systems of constant current regulate is used widely control of lighting and electric heating system. Therefore, in this paper proposed an inverter systems with constant current regulation and power factor correction (PFC) circuit for Lighting and Beaconing of Aerodromes. The effectiveness of the proposed system confirmed through experimental results of CCR.

  • PDF

RESEARCH OF AN ACTIVE FILTER BASED BALANCED POWER SUPPLY SYSTEM FOR RAIL WAY TRACTION

  • Zeng, Guohong;Hao, Rongtai
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.797-801
    • /
    • 1998
  • This paper presents a balanced 3/1 supply scheme for electric railway. By employing an active filter, the current of the three-phrase delivery system is balanced while the load is single phrase, which makes it possible for the traction system to behave like a pure-resistance load, with unity power factor and no harmonics. Simulation results are present to verify the scheme's topology and control strategies.

  • PDF

A Study on the Load Management for the Stability of Power Supply in summer (하계전력수급 안정을 위한 부하관리 대책)

  • Cho, Kyou-Seung;Kang, Won-Koo;Lee, Youn-Seob
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.17-18
    • /
    • 1991
  • In electric Industry, the improvement of load factor by flattening load has been considered to be more important than any other tasks and has received wide concern and interest. Especially while annual peak load had occurred early evening in winter during past decades, but we found the trend has changed so that annual peak load occurred during the daytime in summer since 1981. In this paper we introduce various method for the load management.

  • PDF

CO2 emission Reduction and Load factor improvement of Power Systems, using Geothermal Source Heat Pump (지열히트펌프 활용을 통한 전력계통 부하율 향상 및 CO2 감축)

  • Lee, Geon-Woo;Lee, Sang-Joong;Yang, Seong-Deog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.349-354
    • /
    • 2008
  • August 2008, Our country was announced the Energy Vision 2030 for strengthening response capability climate change by the greenhouse effect, 'Stable supply of energy' and 'Efficient systems'. According to the report, Our country is the world's top 10 is a country that consumes a lot of energy. and more than 97% of the energy because it is dependent on foreign imports, The importance of NRE(New and Renewable Energy) is rising significantly, This paper was applied geothermal heat pump it one kind of the renewable energy equipment, in General buildings, and analyzed the effect of the installation. Thus, to improve the load factor of the Electric power system was proposed, and As a result, can be expected the energy cost savings and the reduction of greenhouse gases, through Economic electric power supply.

  • PDF

Economic Feasibility on the Interconnected Electric Power System in North-East Asia (동북아 전력계통 연계에 따른 경제성 분석)

  • Chung, Koo-Hyung;Han, Seok-Man;Kim, Bal-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.2
    • /
    • pp.76-84
    • /
    • 2006
  • Interstate electric power system, as an alternative for energy cooperation under regional economic block, has been hotly debated before progressing the restructure in electric power industry and rapidly expanded in many regions after 1990s. Especially, since northeast asia has strong supplementation in resource, load shape, fuel mix etc., interconnection of electric power systems in this region may bring considerable economic benefits. This paper implements a mathematical optimization model, ORIRES, proposed by Russia, in analysing the economic feasibility of system interconnection. Additional analyses on the environmental impact of the system interconnection, and sensitivity of key factor inputs have been performed.

A Study on the load control using electric inertia

  • Kim, Gil-Dong;Park, Hyun-Jun;Han, Young-Jae;Jang, Dong-Yuk;Jo, Jung-Min
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.128.1-128
    • /
    • 2001
  • A propulsion system apparatus is needed for a railroad vehicle to test and estimate propulsion performance. The electrical inertia simulator to facilitate the development and testing of propulsion systems, is presented in this paper. It is based on a vector-controlled Induction motor drive supplied from the AC mains through a double PWM converter that provides desirable features such as hi-directional power folw, nearly unity power factor and low harmonic factor at the Ac mains. A theoretical analysis is first presented, followed by a detailed simulation study to assess the overall system performance under dynamic conditions.

  • PDF

Buckling characteristics and static studies of multilayered magneto-electro-elastic plate

  • Kiran, M.C.;Kattimani, S.C.
    • Structural Engineering and Mechanics
    • /
    • v.64 no.6
    • /
    • pp.751-763
    • /
    • 2017
  • This article deals with the buckling behaviour of multilayered magneto-electro-elastic (MEE) plate subjected to uniaxial and biaxial compressive (in-plane) loads. The constitutive equations of MEE material are used to derive a finite element (FE) formulation involving the coupling between electric, magnetic and elastic fields. The displacement field corresponding to first order shear deformation theory (FSDT) has been employed. The in-plane stress distribution within the MEE plate existing due to the enacted force is considered to be equivalent to the applied in-plane compressive load in the pre-buckling range. The same stress distribution is used to derive the potential energy functional. The non-dimensional critical buckling load is accomplished from the solution of allied linear eigenvalue problem. Influence of stacking sequence, span to thickness ratio, aspect ratio, load factor and boundary condition on critical buckling load and their corresponding mode shape is investigated. In addition, static deflection of MEE plate under the sinusoidal and the uniformly distributed load has been studied for different stacking sequences and boundary conditions.

A Study on the analysis of marginal cost using DC load flow in transmission constraint and network partition (송전제약하에서 DC LOAD FLOW를 이용한 한계비용의 분석과 계통의 분할에 관한 연구)

  • Jang, Si-Jin;Jeong, Hae-Seong;Park, Jong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.373-375
    • /
    • 2000
  • By DC load flow approximation, we analyzed marginal cost that is the important factor of price signal for network congestion management and expressed as a function of load. In network congestion, a large scale electric network is partitioned into subnetwork to provide a effetive price signal through zonal pricing. We propose a new network partition technique using marginal cost sensitivity with a variety of load consumption.

  • PDF