• 제목/요약/키워드: Electric Generator

검색결과 924건 처리시간 0.037초

발전기 고정자 권선의 가속열화 특성 (Characteristics of Accelerated Aging in Generator Stator Windings)

  • 김희동;공태식;주영호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.279-280
    • /
    • 2008
  • Accelerated aging tests were conducted under laboratory conditions on two generator stator bars. Electrical stress is applied in No. 1 model stator bar. Electrical and thermal stresses are applied in No. 2 model stator bar. As aging times increased from 0 to 4780h, diagnostic tests were performed on No. 1 and No. 2 model stator bars. Diagnostic tests included AC current, dissipation factor(tan$\delta$) and partial discharge magnitude. The ${\Delta}tan{\delta}$ and $\Deta$I of No. 1 and No. 2 model stator bars increased with increased in aging time.

  • PDF

초음파를 이용한 원자력발전소 증기발생기 전열관의 정략적 결함 평가에 관한 연구 (A Study on Quantitative Flaw Evaluation of Nuclear Power Plant Steam Generator Tube by Ultrasonic Testing)

  • 윤병식;김용식;이희종;이영호
    • 비파괴검사학회지
    • /
    • 제26권1호
    • /
    • pp.12-17
    • /
    • 2006
  • 원자력발전소의 증기발생기는 수천 개의 매우 얇은 두께의 튜브로 구성되어 있다. 이러한 증기발생기의 튜브는 원자력발전소의 1차 계통과 2차 계통의 압력경계를 유지하는 데에 매우 중요한 역할을 하고 있으며, 고온 고압의 열 수력적 상호작용으로 인한 가혹한 운전조건으로 인하여 손상되기 쉽다. 따라서 증기발생기의 구조적 건전성을 평가하기 위하여 많은 시간과 노력이 투입되고 있다. 와전류 검사 방법이 증기발생기 튜브의 건전성을 평가하기 위한 가장 보편적인 비파괴 방법이지만, 와전류 검사의 특성상 결함의 전체 체적에 의하여 신호의 특성이 나타나게 되어 정확한 결함의 크기를 평가하기에는 한계가 있다. 본 연구에서는 증기발생기 튜브의 결함 검출과 정확한 측정을 위하여 초음파 검사기법의 적용 가능성을 확인하였으며, 연구결과를 증기발생기 튜브 검사에 적용 할 경우 검사결과가 크게 향상 될 것으로 기대된다.

정유압 구동식 변속기를 사용한 새로운 파력 발전기 설계 (A New Design of Wave Energy Generator Using Hydrostatic Transmission)

  • 안경관;딩광졍;윤종일
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.171-171
    • /
    • 2010
  • An innovative design of a floating-buoy wave energy converter (WEC) using hydrostatic transmission (HST), named HSTWEC, is presented in this paper. The system is designed to convert ocean wave fluctuation into electricity by using the HST circuit and an electric generator. Based on the floating-buoy concept, the wave forces the sub-buoy to move up and down. Consequently, the electric power can be obtained from the generator in both the moving directions of the sub-buoy through the HST circuit as shown in Fig. 1. In order to investigate the HSTWEC operations, a mathematical model of the system is indispensible. In addition, the method to control the HSTWEC, including: pump displacement control, tension adjustment control and ballast weight control, is also discussed in this paper. Finally, the design concept as well as simulation results indicated that this HSTWEC design is an effective solution and possible to fabricate for wave energy generation.

  • PDF

Wound-rotor induction generator system for random wave input power

  • Kim, Moon-Hwan
    • Journal of information and communication convergence engineering
    • /
    • 제7권1호
    • /
    • pp.46-51
    • /
    • 2009
  • In this paper, the two-axis theory is adopted to analyze the secondary excited induction generator applied to random wave input generation system. The analysis by the two-axis theory helps to know the transmitted power of the induction machine. The electric variables, like as primary and secondary currents, voltages, and electric output power, were able to express as equations. These equations are help to simulate the generation system numerical model and to know the transient state of the system. As it is preferred to stabilize the output voltage and frequency in the constant level, microcomputer controlled VSI connected to the secondary windings supplies the secondary current with slip frequency. For testing the appropriateness of this method, the input torque simulator in the laboratory to drive the secondary excited results show the advantage of secondary excited induction generator system for the random input wave generation system.

이용율과 혼소율을 이용한 발전기의 입출력 특성식 산정 (Calculation of the generator cost functions using the utilization factor of generators and the mixed fuel burning ratio of the generators)

  • 송경빈;남재현;박시우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1270-1272
    • /
    • 1999
  • The generator cost function is one of the basic data for the generation scheduling. Generally the cost functions are obtained form design calculations or from heat rate tests. The real operating condition may be different from the condition of design or the tests. Some of the conditions may not be tested during the periodical maintenance. In order to improve the calculation of the generator cost function, this paper presents a new calculation method of the generator cost functions using the utilization factors of generators and the mixed fuel burning ratio of the generators.

  • PDF

유압 구동식 발전장치의 정주파수 제어 - 시뮬레이션 - (Constant Frequency Control of Generating System Driven by Hydraulic Power - Simulation -)

  • 정용길;오인호
    • 수산해양기술연구
    • /
    • 제26권3호
    • /
    • pp.275-281
    • /
    • 1990
  • This study suggests a new type shaft generator driven by hydraulic power suitable for small size vessels. Since the shaft generator system is very easy to be affected by disturbances such as speed variation of the main engine and the load variation of the generator, a robust servo control must be performed to obtain stable electric power with constant frequency. So, in this study the robust servo control method is adopted to the controller design. Dynamic characteristics on the frequency variations of the electric power output according to the disturbances are investigated by computer simulations. From the considerations of the computer simulation results, it is ascertained that the shaft generator system proposed in this study had good control performances.

  • PDF

화력발전소 터빈 보조기기 제어 관한 고찰 (A Study on Turbine Auxiliary Devices in a Thermal Power Plant)

  • 정창기;최인규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1667-1668
    • /
    • 2008
  • There are three main devices such as boiler producing steam, turbine driving generator and generator producing electricity. An electrical generator in power plant is driven and maintained its speed at rated by steam turbine which is coupled into generator directly. Turbine auxiliary devices such as condenser, deaerator, feed water heater, gland steam condenser, pump recirculation equipment, feed water pump, and so on should be operated well so that the steam turbine exert its maximum efficiency. There are many control loop such as hot well level and condenser recirculation, deaerator level, pegging steam pressure, feed water heater level, feed water pump recirculation. In this paper condenser level control and deaerator level control are going to be described.

  • PDF

A Study of On-line Monitoring System for a KEPCO Pumped Storage Generator/Motor

  • Kim Hee-Dong;Ju Young-Ho;Kim Yong-Joo;Cho Kyu-Bock
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권2호
    • /
    • pp.90-95
    • /
    • 2006
  • An on-line diagnostic test has been studied and performed for the pumped storage generator/motor. This study aims at reducing the diagnostic cost, minimizing the technical dependency on third party manufactures. Further design of on-line diagnostic system such as shorted-turn of rotor winding, partial discharge (PD) of stator winding and air-gap between stator and rotor for pumped storage generator/motor has been verified. In addition, it needs to be validated on site performance of the developed continuous on-line monitoring system for corresponding tasks for the improvement of the availability & reliability during operation.

대용량 터빈발전기 고정자 권선의 정지중 및 운전중 부분방전 특성 (Off-Line and On-Line Partial Discharge Properties of Large Turbine Generator)

  • 김희동;이영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1846-1849
    • /
    • 2000
  • Off-line and on-line partial discharges were measured on a 828MVA, 22kV and direct hydrogen-cooled large turbine generator. Partial discharge tests were conducted using digital partial discharge detector(PDD) and turbine generator analyzer(TGA). PDD and TGA showed that off-line partial discharge pattern seems to be very, similar to that found with on-line. Most of the partial discharge is originating with the stator slot in the three phases. As the partial discharge activity is very low, the stator insulation condition of this generator is very good.

  • PDF