복합다용도 수용가의 전력소비특성 분석 및 전기요금 산정프로그램 개발 (A Study on the Program for Estimation of Electric Rates and the Analysis for Power Consumption in Complex Consumer)

  • 김세동;유상봉;기유경
    • 조명전기설비학회논문지
    • /
    • 제28권12호
    • /
    • pp.103-107
    • /
    • 2014
  • Together with housings, general buildings and industrial facilities, multi-purpose complexes are equipped with various and special equipment. They are often used by many unspecified people, which causes an increase in annual electricity consumption. Because of this, a great amount of money has been spent for electric charge, far more in excess of the budget, so a reasonable electricity rate needs to be estimated. In this study, we surveyed the power consumption, average power use, and annual electricity bill of multi-purpose complexes in the past five years. To see the general tendency of the survey, we conducted a statistical analysis with such parameters as average, maximum, and minimum values. Through regression analysis, we could see the trend of the survey in linear way. Based on the survey, we have developed an electric-rate calculation program to estimate the next year's budget on electricity.

기기의 지진취약도 평가를 위한 구조물 비탄성구조응답계수의 재평가 (Revaluation of Inelastic Structural Response Factor for Seismic Fragility Evaluation of Equipment)

  • 박준희;최인길
    • 한국전산구조공학회논문집
    • /
    • 제28권3호
    • /
    • pp.241-248
    • /
    • 2015
  • 원자력발전소에는 전력생산과 안전과 관련된 수많은 기기들이 존재하고 있다. 기본적으로 원자력발전소의 구조물과 기기는 지진시 탄성거동올 목표로 안전율을 매우 높게 적용하여 설계해 왔다. 그러나 최근 발생한 지진의 규모가 증가함에 따라 설계수준을 초과한 지진에 대한 기기의 안전성을 재평가할 필요가 있다. 본 연구에서는 구조물의 비선형 거동에 의한 층응답을 분석하였고, 비선형해석에 의한 구조물의 비탄성구조응답계수를 재평가하였다. 기기의 지진취약도 평가시 구조물의 비탄성구조응답이 어떤 영향을 주는지 분석하기 위하여 재평가된 구조물의 비탄성구조응답계수와 기존에 사용되어온 구조물 비탄성구조응답계수를 적용하여 지진취약도 평가를 수행하였다. 해석결과에 따르면 비탄성구조응답계수는 기기의 고유진동수, 기기의 위치 그리고 구조물의 동특성에 따라 영향을 받는 것으로 나타났다.

Reliability Evaluation of Power System Operations Considering Time-Varying Features of Components

  • Hu, Bo;Zheng, Ying;Yang, Hejun;Xia, Yun
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1422-1431
    • /
    • 2015
  • The reliability of power system components can be affected by a numbers of factors such as the health level of components, external environment and operation environment of power systems. These factors also affect the electrical parameters of power system components for example the thermal capacity of a transmission element. The relationship of component reliability and power system is, therefore, a complex nonlinear function related to the above-mentioned factors. Traditional approaches for reliability assessment of power systems do not take the influence of these factors into account. The assessment results could not, therefore, reflect the short-term trend of the system reliability performance considering the influence of the key factors and provide the system dispatchers with enough information to make decent operational decisions. This paper discusses some of these important operational issues from the perspective of power system reliability. The discussions include operational reliability of power systems, reliability influence models for main performance parameters of components, time-varying reliability models of components, and a reliability assessment algorithm for power system operations considering the time-varying characteristic of various parameters. The significance of these discussions and applications of the proposed techniques are illustrated by case study results using the IEEE-RTS.

Breakdown Characteristics of SF6 and Liquefied SF6 at Decreased Temperature

  • Choi, Eun-Hyeok;Kim, Ki-Chai;Lee, Kwang-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.765-771
    • /
    • 2012
  • $SF_6$ gas has been used as arc quenching and insulating medium for high and extra high voltage switching devices due to its high dielectric strength, its excellent arc-quenching capabilities, its high chemical stability and non toxicity. Despite of its significant contributions, the gas was classified as one of the greenhouse gas in the Kyoto Protocol. Thus, many researches are conducted to find out the replacement materials and to develop the $SF_6$ gas useless electrical equipment. This paper describes experiments on the temperature change-related breakdown characteristics of $SF_6$ gas ($SF_6$) and $SF_6$ liquid ($LSF_6$) in a model GIS(Gas-Insulated Switchgear) chamber in order to show the possibility of more stable and safe usages of $SF_6$ gas. The breakdown characteristics are classified into three stages, namely the gas stage of $SF_6$ according to Paschen's law, the coexisting stage of $SF_6$ gas with liquid in considerable deviation at lower temperature, and the stage of $LSF_6$ and remaining air. The result shows that the ability of the $LSF_6$ insulation is higher than the high-pressurized $SF_6$. Moreover, it reveals that the breakdown characteristics of $LSF_6$ are produced by bubble-formed $LSF_6$ evaporation and bubbles caused by high electric emission and the corona. In addition, the property of dielectric breakdown of $LSF_6$ is determined by electrode form, electrode arrangement, bubble formation and movement, arc extinguishing capacity of the media, difficulty in corona formation, and the distance between electrodes. The bubble formation and flow separation phenomena were identified for $LSF_6$. It provides fundamental data not only for $SF_6$ gas useless equipment but also for electric insulation design of high-temperature superconductor and cryogenic equipment machinery, which will be developed in future studies.

Study on EMTP Simulation Applying Dual Reactor for Prevention of the Ferro-resonance and VT Burnout in Substation System

  • Kim, Seok-kon;An, Yong-ho;Jang, Byung-tae;Choi, Jong-kee;Lee, Nam-ho;Han, Jung-yeol;Lee, You-jin
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제1권1호
    • /
    • pp.1-8
    • /
    • 2015
  • When the line and switchgear of the substation system are disconnected, ferro-resonance can occur. This happens even if the capacitive reactance and inductive reactance are not equal, which are not common resonance conditions. Resonance conditions vary depending on the busbar configuration environment. Although the damping resistance method applying the existing saturable reactor to cope with ferro-resonance has been successfully applied on site, there can be loss of normal function during long-term operation. The reason is because the rise in the operating frequency of saturable reactors means the saturation number is increased. Therefore, it can no longer function as saturable reactor since the resistor having inadequate capacity is burned out. To address this problem, in this paper, an EMTP-based simulation test was performed by designing and applying a dual reactor method, which adds an extended divergence reactor to the 1st side of the VT. The test result confirms that when the divergence reactor is inserted, the voltage and current values obtained at the 1st side and 2nd side of the VT as well as current values of divergence reactor part were stabilized from the transient phenomena and return to normal values. When compared with existing measures, although this method is similar in adding having a reactor added to a system regarding ferro-resonance, it has the advantage of being able to prevent ferro-resonance in advance since the reactor is added before the system is saturated. In addition, because it does not use damping resistance, it can extend the equipment life and stabilize its operation. Therefore, there are a lot of differences in terms of its operating characteristics and achivement of goal between the conventional method and new divergence reactor method.

EV 상용차용 히트펌프 시스템 냉방 운전 특성에 관한 연구 (A Study on Performance Characteristics of Heat Pump System on Cooling Mode for Light-duty Commercial Electric Vehicles)

  • 전한별;김정일;원헌주;이호성
    • 한국산학기술학회논문지
    • /
    • 제20권12호
    • /
    • pp.69-75
    • /
    • 2019
  • 본 연구의 목적은 EV 경상용차에 적용되는 히트펌프 시스템에 대한 냉방 성능 특성을 실험적으로 분석하는 것이다. EV 경상용차가 운전되는 냉방 운전조건인 외기온도 35 ℃, 내기온도 25 ℃ 상황에서, 히트펌프 시스템의 냉방 특성을 분석하고자, 냉각수의 온도조건, 전동식 압축기 회전수 조건 변화에 대해서, 실험을 진행하였고, 그 결과를 분석하였다. 전동식 압축기 회전수가 증가할수록 냉방 성능이 평균 8.0 %가 증가하였고, 전동식 압축기 소비전력은 27 %가 증가하여서, 시스템 효율은 16.4 %가 감소하는 결과를 보여주고 있다. 전자장비 냉각을 위한 냉각수의 폐열을 활용하기 위하여서, 냉매랑 냉각수가 열교환 하는 칠러를 본 시스템에 적용하였다. 칠러에 적용되는 냉각수의 온도를 35 ℃에서 55℃로 변화시켰을 때, 응축 열원의 증가로 인하여서, 시스템 효율이 평균적으로 18.2 %가 떨어지는 결과를 보여주고 있다. 냉각수 유량 변화 측면에서, 운전 조건을 변화시켰지만, 냉방 성능에는 큰 변화를 보이고 있지 않았다. 향후, 냉각수 폐열을 사용하여서, 히트펌프 시스템에 대한 난방 성능 향상을 위한 연구가 필요한 상황에서, 관련 연구에 추가 할 예정이다.

진단용 방사선발생장치의 검사기준을 적용한 동물병원의 방사선 안전관리 (The Radiation Safety Management in the Animal Hospital Using Inspection Standard of Diagnosis Radiation System)

  • 김상우;임재동;한동균;성열훈
    • 대한안전경영과학회지
    • /
    • 제12권4호
    • /
    • pp.73-80
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using inspection standard of X-ray generator for diagnosis. The surveys for inspection standard system, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The inspection standard included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. The surveys of equipment condition and safety supervision used one-on-one interview with 5 points measurement. As a result, 44.44% of reproducibility of dose exposure was proper, 81.25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test. The 100mA electric capacity of X-ray generator for diagnosis was popular with 44.44%, and its 55.56% was purchased used equipment. Monthly average of less than 50 times (61.11%) was top frequency in use, and no animal clinic had a thermo-luminescence dosimeter(TLD). The 16 animal clinics with radiation safety zone and 2 without radiation safety zone were appeared.

중소형 회로 차단기에 적용 가능한 한류 메커니즘의 개발 (A Study on the impact on the quality of hemming the number of hemming process)

  • 이제덕;박종식;임재국;박동희;박민호;최계광;김세환;윤재웅;이춘규
    • Design & Manufacturing
    • /
    • 제10권1호
    • /
    • pp.41-45
    • /
    • 2016
  • Electrical equipment in factories, buildings, etc. with the development of the industry has become a large capacity. By the development, electric load also become diversified and there is also highly functional requirements being electrical equipment. Particularly in the small and medium-sized circuit breakers, tend to preferentially consider the economy stands out and improvements in safety, ease of mounting and connection through the modularity of the basic dimensions compact and cost to block expansion of the scope of the development of capacity, etc. The product having a competitive has been strongly required. In order to implement the circuit breakers of breaking capacity and compact at the same time taking into account the economic development of this technology applied to the current-limiting mechanism is essential budget or the current limiting mechanism is currently available mechanisms applicable to small and medium-sized frame (frame) can not do it. In this paper, at the same time satisfying the economic efficiency, by minimizing the load force of the moving contactor (moving contactor) to be applied to small and medium frame other hand to secure the economical efficiency without using high speed contact parting acceleration of the moving contactor conventional current-limiting mechanism, and to develop a current-limiting mechanism that can be satisfied with the same or higher performance to meet the needs of the market.

변전소의 AC/DC 겸용 비상 및 복구 등에 관한 연구 (A Study on the Emergency and Recovery AC/DC Combination Lamps in the Electric Substations)

  • 박준열;안윤기;김종수;신혜영
    • 조명전기설비학회논문지
    • /
    • 제24권6호
    • /
    • pp.27-34
    • /
    • 2010
  • 본 연구는 변전소(사무실) 비상 및 복구등 설비환경 개선차원으로 실시하였다. 기존 비상등의 낮은 조도로 인해 발생하는 문제점을 해결하기 위해 AC/DC 겸용 형광등 안정기 및 스위치를 연구하였다. 또한 조도기준을 상시등의 5~10[%]가 아닌 한국산업규격 조도기준(KS A 3011)에 따른 원자력발전소 조도기준과 안전조명 조도기준을 참고로 변전소 각 실별 조도기준을 제안하였다. 마지막으로 본 연구에서 제안한 내용의 타당성을 검토하기 위해 실험을 하였다. 그 결과 축전지 용량을 증가시키지 않으면서도 비상 및 복구등의 조도를 높일 수 있었다.

154 kV 및 345 kV 주변압기 부싱의 내진성능 시험 연구 (The Experimental Study on Seismic Capacity of 154 kV & 345 kV Main Transformer Bushings)

  • 황경민;함경원;김경환
    • 한국지진공학회논문집
    • /
    • 제22권2호
    • /
    • pp.87-94
    • /
    • 2018
  • In this study, seismic performance of bushings and their connection parts was analyzed by performing shaking table tests for various types of bushings widely used as auxiliary equipment of main transformers in domestic substations. As a result of the seismic tests of five types of 154 kV bushings according to the manufacturers, all the bushings secured the structural integrity even at the acceleration of 1.4 g and it was found that leakage of insulating oil didn't occur. Also, the average acceleration amplification rate at the upper part of the bushings was about 2.5 to 3.0 times higher than the lower one. On the other hand, when a representative 345 kV bushing was subjected to the seismic test, the structural integrity was secured even at 1.0 g acceleration similar to the design earthquake load level, but in this test, leakage of insulating oil occurred. However, when a stiffener restricting the connection of the bushing is installed in the same 345 kV bushing, the displacement of the bushing connection is controlled and the stiffener prevent the oil from leaking even at the acceleration of the designed seismic level.