• 제목/요약/키워드: Electric Equipment Capacity

검색결과 106건 처리시간 0.024초

배전선로 운전용량 상향에 따른 개폐기 설치 기준 분석 (Analysis of the Switch Installation Criteria by Increasing Operating Capacity in Distribution Line)

  • 조남훈;하복남;이흥호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권6호
    • /
    • pp.290-295
    • /
    • 2002
  • The present assignment in installing the number of switches for distribution line was made on the basis of a normal feeder capacity 7,000kVA in KEPCO(Korea Electric Power Corporation), Korea. But the normal capacity is revised to 10000kVA in 1998. Even increasing limit of the operating capacity of the distribution lines enables us to give some benefit for the operation flexibility and investment cost of the distribution system. It is disadvantageous in the viewpoint of supply reliability. In distribution systems, switches are equipped to improve the reliability of distribution systems by minimizing the outage section due to fault and maintenance. Utility generally improves the reliability by minimizing the length of outage section, which is caused by fault and maintenance, through switch equipment on distribution system. In order to cope with the changes such as operation capacity, it is necessary to study whether the present criteria is reasonable or not, also to confirm whether the present criteria of installing switches in line is improved or not. In this study, we proposes the number of switch per feeder on the basis of present operation capacity in distribution system.

Battery State Estimation Algorithm for High-Capacity Lithium Secondary Battery for EVs Considering Temperature Change Characteristics

  • Park, Jinho;Lee, Byoungkuk;Jung, Do-Yang;Kim, Dong-Hee
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.1927-1934
    • /
    • 2018
  • In this paper, we studied the state of charge (SOC) estimation algorithm of a high-capacity lithium secondary battery for electric vehicles (EVs) considering temperature characteristics. Nonlinear characteristics of high-capacity lithium secondary batteries are represented by differential equations in the mathematical form and expressed by the state space equation through battery modeling to extract the characteristic parameters of the lithium secondary battery. Charging and discharging equipment were used to perform characteristic tests for the extraction of parameters of lithium secondary batteries at various temperatures. An extended Kalman filter (EKF) algorithm, a state observer, was used to estimate the state of the battery. The battery capacity and internal resistance of the high-capacity lithium secondary battery were investigated through battery modeling. The proposed modeling was applied to the battery pack for EVs to estimate the state of the battery. We confirmed the feasibility of the proposed study by comparing the estimated SOC values and the SOC values from the experiment. The proposed method using the EKF is expected to be highly applicable in estimating the state of the high-capacity rechargeable lithium battery pack for electric vehicles.

건물의 수요율 및 부등율 기준설정에 관한 연구 (A Study on the Design Standard of Demand Factor and Diversity Factor)

  • 지철근;곽희로;강원구
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제4권1호
    • /
    • pp.54-62
    • /
    • 1990
  • 본 연구는 우리나라 전력다소비 건물의 전기설비용량, 전력사용실태를 조사하여 통계적 처리를 함으로써 합리적인 수요율과 부등율 기준을 설정하였다. 설정된 수요율과 부등율 기준을 적용하면 설비투자비 감소, 전력손실 감소, 전기요금 절약 및 설비 이용율 개선에 크게 기여할 수 있다. 그러므로 설정된 수요율과 부등율 기준은 이행 관제규정을 개정하기 위하여 활용되어야 할 것이다.

  • PDF

사무소용건물의 변전시설밀도 및 수용률 기준설정에 관한 연구 (A Study on the Design Standard of Substation Facility Density and Demand Factor in Office Buildings)

  • 김세동;정동효
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제6권6호
    • /
    • pp.42-48
    • /
    • 1992
  • This paper shows a reasonable design standard of substation facility density and demand factor in office buildings, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, electric power consumption, etc for 121 buildings. The saving of electric equipment investment, the decrease of power loss, the improvement of facilities utilization and the decrease of electric power rates an be contributed by the application of the design standard must be applied by the revision of current regulations and laws.

  • PDF

Coordinated Control Strategy and Optimization of Composite Energy Storage System Considering Technical and Economic Characteristics

  • Li, Fengbing;Xie, Kaigui;Zhao, Bo;Zhou, Dan;Zhang, Xuesong;Yang, Jiangping
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.847-858
    • /
    • 2015
  • Control strategy and corresponding parameters have significant impacts on the overall technical and economic characteristics of composite energy storage systems (CESS). A better control strategy and optimized control parameters can be used to improve the economic and technical characteristics of CESS, and determine the maximum power and stored energy capacity of CESS. A novel coordinated control strategy is proposed considering the coordination of various energy storage systems in CESS. To describe the degree of coordination, a new index, i.e. state of charge coordinated response margin of supercapacitor energy storage system, is presented. Based on the proposed control strategy and index, an optimization model was formulated to minimize the total equivalent cost in a given period for two purposes. The one is to obtain optimal control parameters of an existing CESS, and the other is to obtain the integrated optimal results of control parameters, maximum power and stored energy capacity for CESS in a given period. Case studies indicate that the developed index, control strategy and optimization model can be extensively applied to optimize the economic and technical characteristics of CESS. In addition, impacts of control parameters are discussed in detail.

전력보상설비의 상호 협조제어에 따른 운영여유용량의 확보 (Securing Operation Margin Capacity as Coordination Control among the Power Compensation Equipments)

  • 이상덕;백영식
    • 전기학회논문지
    • /
    • 제59권6호
    • /
    • pp.1011-1016
    • /
    • 2010
  • It is an important issue to electric power system operations that it can reliably supply large-capacity power to consumption area as due to increasing power demand growth. For this purpose, The FACTS equipment based on Power IT technology with the existing mechanical compensators has been applied to power system. Therefore we suggest on this paper that a plan for coordination control of multiple power compensation equipment in order to increase the utilization of each facility and secure operation margin capacity. As the result of simulation, it is possible to cope actively with a suddenly changed power system. This helps greatly for the voltage stability and supply reliability in a suddenly changed power system.

벡터제어 유도전동기를 이용한 축소형 관성 시뮬레이터 (A miniature inertia simulator using vector controlled induction motor)

  • 김길동;한영재;박현준;변윤섭;장동욱;조정민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.413-415
    • /
    • 2001
  • A railroad vehicle(Light weight electric rail car, Urban railroad, High-speed railroad) need to construct propulsion- system capacity experiment equipment to test performance or to estimate confidence. Experiment equipment in interior have been used Flywheel which is equal to the same inertia as railroad straight moment. But mechanical inertia using flywheel don't change inertia and can't embody traveling-struggle which is similar to actual traveling-struggle. We propose the method to embody electric railroad load system with inertia using electric servo motor in order to get the characteristic of real vehicle load, and confirm this algorithm with simulation and experiment.

  • PDF

LCD를 이용한 통전상태 표시기 개발 (Voltage Application Indicator Using Liquid Crystal Device)

  • 구경완;류승헌;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1757-1759
    • /
    • 2000
  • To make a inspection and maintenance of the high voltage equipment, electric machinery to transmit and distribute the electric power, the appearance of a simple and inexpensive indicator with which the charge condition of bare conductor parts could be read at a Stance has been needed. Liquid crystal has recently been expanding its application rapidly in appliances for everyday use. Since its display energy is extremely small, it is possible to obtain the working current with simple condenser voltage divider that makes use of stray capacity when it is applied to electric power equipment. Thus, an apparatus has finally appeared which is close to the one they have sought and indicates the existence of voltage impressions.

  • PDF

Experimental Study on Combined Ocean Thermal Energy Conversion with Waste Heat of Power Plant

  • Jung, Hoon;Jo, Jongyoung;Chang, Junsung;Lee, Sanghyup
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제5권3호
    • /
    • pp.215-222
    • /
    • 2019
  • This work is experimental study of 10 kW specialized Combined Ocean Thermal Energy Conversion. We propose a C-OTEC technology that directly uses exhaust thermal energy from power station condensers to heat the working fluid (R134a), and tests the feasibility of such power station by designing, manufacturing, installing, and operating a 10 kW-pilot facility. Power generation status was monitored by using exhaust thermal energy from an existing power plant located on the east coast of the Korean peninsula, heat exchange with 300 kW of heat capacity, and a turbine, which can exceed enthalpy efficiency of 45%. Output of 8.5 kW at efficiency of 3.5% was monitored when the condenser temperature and seawater temperature are $29^{\circ}C$ and $7.5^{\circ}C$, respectively. The evaluation of the impact of large-capacity C-OTEC technology on power station confirmed the increased value of the technology on existing power generating equipment by improving output value and reducing hot waste water. Through the research result, the technical possibility of C-OTEC has been confirmed, and it is being conducted at 200 kW-class to gain economic feasibility. Based on the results, authors present an empirical study result on the 200 kW C-OTEC design and review the impact on power plant.

지하상가 부하설비의 사용특성과 전력관리 방안 연구 (A Study on the Reasonable Power Demand Method and Load Characteristics in Underground Streets)

  • 김세동;최도혁;류승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.235-237
    • /
    • 1996
  • This paper shows a reasonable power demand method and load characteristics in underground streets, that was made by the systematic and statistical way considering actual conditions, such as investigated electric equipment capacity, electric power consumption, load characteristics, etc for 13 underground streets.

  • PDF