• Title/Summary/Keyword: Electric Current Control

Search Result 936, Processing Time 0.029 seconds

The Study on the improvement of dental technician practical examination I (치과기공사 실기시험 개선에 관한 조사 연구 I)

  • Bae, Eun-Jeong;Kim, Woong-Chul;Chung, In-Sung;Nam, Sang-Yong;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.34 no.4
    • /
    • pp.413-421
    • /
    • 2012
  • Purpose: The purpose of this study is to investigate the improvement measure of dental technician practical examination. Methods: A survey was performed on 111 dental technicians who were self-written questionnaire. The results were analyzed by SPSS 12.0. The collected data was analyzed by frequency and chi-square test. Results: Questions most necessary work tools with the articulator was the highest with 55.9%, Electric wax carver(16.2%), heating clear(14.4%), CAD/CAM program(9.0%) was in the order. The need for additional practical test in response to actions included maxillary and mandibular comments occlusal work that you have to wax up the highest rate of 63.8%. Items most in need of improvement was strengthen of clinically oriented(48.0%), separation of written and practical(14.6%), control the degree of difficulty(11.4%) were the next order. Conclusion: Based on the results of this study, the current dental technician did not show major problems in the practical test. However, clinicians should be strengthened mainly. To do this, the use of the articulator is essential.

An application of the electrostatic spray technology to increase scrubbing efficiency of SO$_{2}$ emitted from thermal systems (열시스템에서 생성된 SO$_{2}$ 가스의 배출저감을 위한 정전기 분무 원리의 응용)

  • Jeong, Jae-Yun;Byeon, Yeong-Cheol;Hwang, Jeong-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.8
    • /
    • pp.1068-1076
    • /
    • 1997
  • Emission control of acid exhaust gases from coal-fired power plants and waste incinerators has become an increasing concern of both industries and regulators. Among those gaseous emissions, SO$_{2}$ has been eliminated by a Spray Drying Absorber (SDA) system, where the exhaust gas is mixed with atomized limestone-water slurry droplets and then the chemical reaction of SO$_{2}$ with alkaline components of the liquid feed forms sulfates. Liquid atomization is necessary because it maximizes the reaction efficiency by increasing the total surface area of the alkaline components. An experimental study was performed with a laboratory scale SDA to investigate whether the scrubbing efficiency for SO$_{2}$ reduction increased or not with the application of a DC electric field to the limestone-water slurry. For a selected experimental condition SO$_{2}$ concentrations exited from the reactor were measured with various applied voltages and liquid flow rates. The applied voltage varied from -10 to 10 kV by 1 kV, and the volume flow rate of slurry was set to 15, 25, 35 ml/min which were within the range of emission mode. Consequently, the SO$_{2}$ scrubbing efficiency increased with increasing the applied voltage but was independent of the polarity of the applied voltage. For the electrical and flow conditions considered a theoretical study of estimating average size and charge of the atomized droplets was carried out based on the measured current-voltage characteristics. The droplet charge to mass ratio increased and the droplet diameter decreased as the strength of the applied voltage increased.

The Diagnostic Values of Ryodoraku and Pulse Analysis for Respiratory Disease Patients (호흡기계 환자에 대한 양도락 ${\cdot}$ 맥진검사의 진단적 가치)

  • Hwang, Joon-Ho;Jung, Seung-Yeon;Jung, Sung-Ki
    • The Journal of Internal Korean Medicine
    • /
    • v.28 no.3
    • /
    • pp.560-569
    • /
    • 2007
  • Objectives : Ryodoraku is a physiological function test using electric current, and is closely related to skin sympathetic tone. Pulse analysis is known to reflect cardiovascular reactivity. There has been no report on the correlation between ryodoraku and pulse analysis in respiratory diseases. The present study examined the diagnostic values of ryodoraku and pulse analysis for respiratory disease patients Methods : For this study, we conducted ryodoraku and pulse analysis in 103 people including 79 respiratory disease outpatients who visited the $5^{th}$ Internal Department of the Oriental Medicine Hospital of Kyung Hee University during the period from January 1, 2003 to July 25, 2006, and 24 volunteers who did not have any respiratory symptoms or disease history. The respiratory disease patients were divided into five sub-groups according to their symptom: cough-sputum group, wheezing-dyspnea group ' nasal symptoms group. cold-prone group, and fatigue prone group. We compared the disease groups with the control group in six items as follows : mean ryodoraku, mean H1, mean elastic index, the percentage of those with mean ryodoraku below $40{\mu}A$, the percentage of those with HI beyond the physiological range, and the ratio of left : right of elastic index Results and Conclusions : Ryodoraku and pulse analysis were found to have a high value as quantitative diagnosis tools reflecting individuals' weakness and firmness. The results of this research suggest that ryodoraku and pulse analysis have value as tools for diagnosing respiratory diseases.

  • PDF

Reduction of the the Ground Surface Potential Gradients by Installing Auxiliary Grounding Grids (보조접지그리드의 시설에 의한 대지표면전위경도의 저감)

  • 이승칠;엄주홍;이복희;김효진
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.121-129
    • /
    • 2002
  • The present paper describes a technique for installing an effective grounding grids, the major objective is forced on the experimental evaluation of the performance and characteristics with the arrangement and installation method for grounding grids consisting of the means to protect electric shock, electronics and computerized facilities against lightning, switching and ground fault surges. The study is oriented on two major areas: (1) the analysis of the ground surface potential gradient with the arrangement of grounding grids, (2) the control of the dangerous ground surface potential rise. The experiments wee carried out with the impulse currents as a function of the installation method or arrangement of grounding grids. An installation method of the inclined auxiliary grounding grid was proposed to overcome the drawbacks of equally spared grounding grids, i.e. an appropriate design concept far the installation of grounding grids was found out, It has been shown that the installation of the intwined auxiliary grounding grid can also result in a mere than 50% decrease in the maximum potential gradient on the ground surface and enhance the level of safety for persons and electronic equipments..

Research Trends for Performance, Safety, and Comfort Evaluation of Agricultural Tractors: A Review

  • Kabir, Md. Shaha Nur;Ryu, Myong-Jin;Chung, Sun-Ok;Kim, Yong-Joo;Choi, Chang-Hyun;Hong, Soon-Jung;Sung, Je-Hoon
    • Journal of Biosystems Engineering
    • /
    • v.39 no.1
    • /
    • pp.21-33
    • /
    • 2014
  • Background: Significant technological development and changes happened in the tractor industries. Contrariwise, the test procedures of the major standard development organizations (SDO's) remained unchanged or with a little modification over the years, demanding new tractor test standards or improvement of existing ones for tractor performance, safety, and comfort. Purpose: This study focuses on reviewing the research trends regarding performance, safety and comfort evaluation of agricultural tractors. Based on this review, few recommendations were proposed to revise or improve the current test standards. Review: Tractor power take-off power test using the DC electric dynamometer reduced human error in the testing process and increased the accuracy of the test results. GPS signals were used to determine acceleration and converted into torque. High capacity double extended octagonal ring dynamometer has been designed to measure drawbar forces. Numerical optimization methodology has been used to design three-point hitch. Numerous technologies, driving strategies, and transmission characteristics are being considered for reducing emissions of gaseous and particulate pollutants. Engine emission control technology standards need to be revised to meet the exhaust regulations for agricultural tractors. Finite Element Analysis (FEA) program has been used to design Roll-Over Protective Structures (ROPS). Program and methodology has been presented for testing tractor brake systems. Whole-body vibration emission levels have been found to be very dependent upon the nature of field operation performed, and the test track techniques required development/adaptation to improve their suitability during standardized assessment. Emphasizes should be given to improve visibility and thermal environment inside the cab for tractor operator. Tractors need to be evaluated under electromagnetic compatibility test conditions due to large growing of electronic devices. Research trends reviewed in this paper can be considered for possible revision or improvement of tractor performance, safety, and comfort test standards.

Design of a 6-Axis Inertial Sensor IC for Accurate Location and Position Recognition of M2M/IoT Devices (M2M / IoT 디바이스의 정밀 위치와 자세 인식을 위한 6축 관성 센서 IC 설계)

  • Kim, Chang Hyun;Chung, Jong-Moon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.1
    • /
    • pp.82-89
    • /
    • 2014
  • Recently, inertial sensors are popularly used for the location and position recognition of small devices for M2M/IoT. In this paper, we designed low power, low noise, small sized 6-axis inertial sensor IC for mobile applications, which uses a 3-axis piezo-electric gyroscope sensor and a 3-axis piezo-resistive accelerometer sensor. Proposed IC is composed of 3-axis gyroscope readout circuit, two gyroscope sensor driving circuits, 3-axis accelerometer readout circuit, 16bit sigma-delta ADC, digital filter and control circuit and memory. TSMC $0.18{\mu}m$ mixed signal CMOS process was used. Proposed IC reduces 27% of the current consumption of LSM330.

Electro-Magnetic Field Analysis for Optimal design of Magneto-Rheological Fluid Damper Core (자기점서유체 댐퍼 코어의 최적화 설계를 위한 전자기장 해석)

  • Song, June-Han;Son, Sung-Wan;Chun, Chong-Keun;Kwon, Young-Chul;Ma, Yang-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.6
    • /
    • pp.1511-1517
    • /
    • 2008
  • The magneto-rheological fluid expresses different cohesiveness according to the strength of the external electric current. The magneto-rheological fluid damper, which uses such characteristics of the fluid, generates shear force due to the fluid's cohesiveness. The core can be said to determine the magneto-rheological fluid damper's performance. This study uses the finite element analysis to compare the performance of different electromagnetic forces, which are affected by the shapes of the coil, and thus to find the optimum design for the core. In addition, as a step to construct a high-efficient damper, we suggest a type of damper that can control multiple coils and compares the performance of this damper and that of the standard damper by comparing the performance of their electro-magnetic fields.

Stable Desalination of Hardness Substances through Charge Control in a Capacitive Deionization System (축전식 탈염 시스템에서 전하량 제어를 통한 경도물질의 안정적인 탈염)

  • Kim, Yoon-Tae;Choi, Jae-Hwan
    • Applied Chemistry for Engineering
    • /
    • v.30 no.4
    • /
    • pp.472-478
    • /
    • 2019
  • A stable desalination method of the hardness substance such as $Ca^{2+}$ by controlling the total charge (TC) supplied to the membrane capacitive deionization (MCDI) cell was studied. The adsorption (1.5 V) and desorption (0.0 V) were repeated 30 times while varying the TC in the adsorption process. The concentration and pH of effluent, adsorption and desorption amounts, current densities and cell potentials were analyzed in the desalination process. The maximum allowable charge (MAC) of the carbon electrode used in MCDI cell was measured to be 46 C/g. As a result of operation at TC (40 C/g) below the MAC value, electrode reactions did not occur, resulted in the stable desalination characteristics for a long-term operation. When operating at TCs (50, 60 C/g) above the MAC value, however, the concentration and pH of effluent varied greatly. Also, the scale was formed on the electrode surface due to electrode reactions, and the electric resistance of the cell gradually increased. It was thus concluded that it is possible to remove stably the hardness substance without any electrode reactions by controlling the charge supplied to MCDI cell during the adsorption process.

A Study on a PDA-Based Ubiquitous Healthcare System for the Management of Chronic Diseases (만성질환 관리를 위한 PDA폰 기반 이동형 방문건강관리 시스템 개발)

  • Son, Sung-Yong;Hwang, Won-Sook;Yee, Yang-Hee;Kim, Chang-Seob;Lim, Chae-Seung;Park, Gil-Hong
    • Journal of Home Health Care Nursing
    • /
    • v.14 no.1
    • /
    • pp.18-22
    • /
    • 2007
  • Purpose: The rapid change to an aging society generates an increase in the incidence of chronic diseases. Many chronic patients have been facing their illnesses without enough preparation. In order to solve these problems, we designed and tested a public healthcare service based on ubiquitous technology. Method: Telemedicine has emerged as new medical care system of chronic disease. However, public potential of its technology is difficult to know under current traditional health care system. In this work, we developed a Personal Digital Access (PDA) phone based healthcare system by trained visiting nurses for elderly patients. A field test was performed by SeongBuk Public Health Center in Seoul, Republic of Korea (ROK). Result: Surveys were generated to assess the effects of this system compared to conventional public health system. Findings of trials demonstrate that healthcare coordination enhanced by PDA phone technology is satisfactory to the patients and nurses compared to previous one because prompt responses arouse their recognition of health. Conclusion: Ubiquitous healthcare system applied to public health service proved to be efficient and time-saving to monitor and control the chronic illnesses of large population.

  • PDF

Generation of Charged Clusters and their Deposition in Polycrystalline Silicon Hot-Wire Chemical Vapor Deposition (열선 CVD 증착 다결정 실리콘에서 전하를 띈 클러스터의 생성 및 증착)

  • Lee, Jae-Ik;Kim, Jin-Yong;Kim, Do-Hyeon;Hwang, Nong-Moon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.11a
    • /
    • pp.561-566
    • /
    • 2005
  • Polycrystalline silicon films were deposited using hot wire CVD (HWCVD). The deposition of silicon thin films was approached by the theory of charged clusters (TCC). The TCC states that thin films grow by self-assembly of charged clusters or nanoparticles that have nucleated in the gas phase during the normal thin film process. Negatively charged clusters of a few nanometer in size were captured on a transmission electron microscopy (TEM) grid and observed by TEM. The negatively charged clusters are believed to have been generated by ion-induced nucleation on negative ions, which are produced by negative surface ionization on a tungsten hot wire. The electric current on the substrate carried by the negatively charged clusters during deposition was measured to be approximately $-2{\mu}A/cm^2$. Silicon thin films were deposited at different $SiH_4$ and $H_2$ gas mixtures and filament temperatures. The crystalline volume fraction, grain size and the growth rate of the films were measured by Raman spectroscopy, X-ray diffraction and scanning electron microscopy. The deposit ion behavior of the si1icon thin films was related to properties of the charged clusters, which were in turn controlled by the process conditions. In order to verify the effect of the charged clusters on the growth behavior, three different electric biases of -200 V, 0 V and +25 V were applied to the substrate during the process, The deposition rate at an applied bias of +25 V was greater than that at 0 V and -200 V, which means that the si1icon film deposition was the result of the deposit ion of charged clusters generated in the gas phase. The working pressures had a large effect on the growth rate dependency on the bias appled to the substrate, which indicates that pressure affects the charging ratio of neutral to negatively charged clusters. These results suggest that polycrystalline silicon thin films with high crystalline volume fraction and large grain size can be produced by control1ing the behavior of the charged clusters generated in the gas phase of a normal HWCVD reactor.

  • PDF